This study aimed to investigate the influence of longitudinal steel embedded tubes located at the center of the column cross-section on the behavior of reinforced concrete (RC) columns. The experimental program consisted of 8 testing pin-ended square sectional columns of 150×150 mm, having a total height of 1400 mm, subjected to eccentric load. The considered variables were the steel square tube sizes of 25, 51 and 68 mm side dimensions and the load eccentricity (50 and 150) mm. RC columns were concealed steel tubes with hollow ratios of 3%, 12% and 20% depending on tube sizes used. The experimental results indicated an improvement in the overall behavior of eccentric columns when steel embedded tubes are used. The maximum gain in strength was about 59% for the hollow ratio of 20% with e/h=1. The test results show that the inserted steel pipe improves strength, ductility and enables these columns to absorb more energy than a similar solid column.
A Bayesian formulation of the ridge regression problem is considerd, which derives from a direct specification of prior informations about parameters of general linear regression model when data suffer from a high degree of multicollinearity.A new approach for deriving the conventional estimator for the ridge parameter proposed by Hoerl and Kennard (1970) as well as Bayesian estimator are presented. A numerical example is studied in order to compare the performance of these estimators.
Brachycerous Dipteran species on alfalfa plant Medicago sativa surveyed in several regions of Iraq from March to November 2012. The study was registered 14 species belonging to nine genera and four families. The results showed that Limnophra quaterna, Atherigona laevigata and Atherigona theodori as new records to Iraq and new pests of alfalfa.
The Asphalt cement is produced as a by-product from the oil industry; the asphalt must practice further processing to control the percentage of its different ingredients so that it will be suitable for paving process. The objective of this work is to prepare different types of modified Asphalt cement using locally available additives, and subjecting the prepared modified Asphalt cement to testing procedures usually adopted for Asphalt cement, and compare the test results with the specification requirements for the modified Asphalt cement to fulfill the paving process requirements. An attempt was made to prepare the modified Asphalt cement for pavement construction in the laboratory by digesting each of the two penetration grade Asphalt c
... Show MoreThe aim of this study is to formulate and evaluate ezetimibe nanoparticles using solvent antisolvent technology. Ezetimibe is a practically water-insoluble drug which acts as a lipid lowering drug that selectively inhibits the intestinal absorption of cholesterol and related phytosterols. Ezetimibe prepared as nano particles in order to improve its solubility and dissolution rate.
Thirty formulas were prepared and different stabilizing agents were used with different concentrations such as poly vinyl pyrrolidone (PVPK-30), poly vinyl alcohol (PVA), hydroxy propyl methyl cellulose E5 (HPMC), and poloxamer. The ratios of drug to stabilizers used to prepare the nanoparticles were 1: 2, 1:3 and 1:4.
The prepared nanoparticles
... Show MoreBackground: Melatonin is the main hormone secreted by the pineal gland. This indole compound (N-acetyl-5-methoxytryptamine) is derived from serotonin after two biochemical steps. Melatonin has been implicated in some pharmacological effects including sedative/hypnotic, anticonvulsant activity and others. The aim of this study was to investigate the antinociceptive effect of different doses of melatonin administered i.p. to mice, and then, to find the dose- response line of melatonin in mice as analgesic agent.
Methods: The dose response effect of melatonin (10, 50, and 100mg/kg) were assessed against control using tail flick test in mice as a model of nociceptive pain. In this model, all doses of melatonin were given intraperitoneally
The Educational Ideology of John Dewey
University of Baghdad college of Medicine - Cited by 1 - Human Anatomy
Radiation measuring devices need to process calibration which
lose their sensitivity and the extent of the response and the amount of
stability under a changing conditions from time to time and this
period depends on the nature and use of field in which used devices.
A comparison study was done to a (451P) (ionization chamber
survey meter) and this showed the variation of calibration factor in
five different years. This study also displayed the concept of
radiation instrument calibration and necessity of every year
calibration of them.
In this project we used the five years calibration data for ionization
chamber survey meter model Inspector (451P) to get that the values
of Calibration Factor (CF) and Res
Chalcopyrite thin films were one-step potentiostatically deposited onto stainless steel plates from aqueous solution containing CuSO4, In2(SO4)3 and Na2S2O3.The ratio of (In3+:Cu2+) which involved in the solution and The effect of cathodic potentials on the structural had been studied. X-ray diffraction (XRD) patterns for deposited films showed that the suitable ratio of (In3+:Cu2+) =6:1, and suitable voltage is -0.90 V versus (Ag/AgCl) reference electrode