Preferred Language
Articles
/
RxYtU4cBVTCNdQwCfUU4
The reliability of using light therapy compared with LASER in pain reduction of temporomandibular disorders: a randomized controlled trial
...Show More Authors
Abstract<sec> <title>Background

Temporomandibular Disorders (TMD) refer to a group of symptoms where pain is the most leading cause to demand a treatment by the patient. Light therapies are of great importance at current times due to its biosafety and non-invasive quality when used for the management of TMD symptoms. This study aimed to evaluate the efficacy of red LED light with low-level LASER in treating TMD patients.

Materials and methods

A double-blind randomized clinical study was conducted and included 60 patients along 3 groups (20 for each group) presented with myofascial pain related to TMD. Patients were randomly divided into 3 groups. Group A were managed by applying the LED light device into the trigger points without switching the device on. A red LED light was given to group B for 5 min at the tender muscles. Group C were treated by using low-level LASER therapy for 30 s. Patients were evaluated for any improvements regarding the pain score, presence of trigger points, and trismus along 4 visits (1 week interval between each visit). Any side effects related to the 2 devices were also assessed.

Results

Both group B and C patients showed a statistically significant improvement in the pain value (P < 0.05) at the 3rd and 4th visits when compared to group A. Regarding tenderness, there was a reduction in the number of trigger points in both study groups; however, the results were insignificant in group B. Statistics showed insignificant differences between group B & C patients regarding pain and number of trigger points at all visits (P > 0.05).

Conclusion

Both LED light and LASER therapies could effectively relieve pain associated with myogenic TMD as there were no important differences between their outcomes. However, the biosafety and lower cost of the LED light device compared to the LASER should also be considered.

Trial Registration This clinical trial was prospectively registered (TCTR ID: TCTR20190507002) on 07/05/2019. URL: http://www.thaiclinicaltrials.org/show/TCTR20190507002

Crossref
View Publication
Publication Date
Tue Feb 28 2023
Journal Name
Egyptian Journal Of Chemistry
Application of UV-A light Operating Photoreactor for Green Degradation of Direct Blue 15 through the Photo-Fenton-like process: Effects and Box-Behnken Optimization
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Jun 30 2021
Journal Name
Journal Of Economics And Administrative Sciences
The role of Iraqi trade policies in stimulating productive sectors to grow for the period (2003-2019) (an analytical study in light of the Malaysian experience)
...Show More Authors

The research deals with analyzing the influencing role of trade policies in the growth and development of productive economic sectors and their contribution to GDP and its reflection on workforce employment. Studies have proven the success of the Malaysian experience in stimulating the productive economic sectors to grow and their contribution to the gross domestic product with an increase in the growth of local markets and access to international markets for national products. The research also deals with the ineffectiveness of Iraqi trade policies after 2003 in stimulating the productive economic sectors (agricultural and industrial) on economic growth, as most of the increase in Iraqi GDP growth throughout the study period was

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 15 2020
Journal Name
Biochem. Cell. Arch.
EFFECT OF LYCOPENE ANTIOXIDANT GEL AS ADJUNCTIVE THERAPY TO CONVENTIONAL PERIODONTAL TREATMENT
...Show More Authors

Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Effect of CO2 Laser Irradiation on the Topographic and Optical Properties of CdO Thin Films
...Show More Authors

     In this study, cadmium oxide (CdO) was deposited on glass bases by thermal chemical spraying technique at three concentrations (0.05, 0.1, 0.15) M and then was irradiated by CO2 laser with 10.6 μm wave length and 1W power. The results of the atomic force microscope AFM test showed that the surfaces of these CdO thin films were homogenous and that the laser irradiated effect resulted in decreasing the roughness of the surface as well as the heights of the granular peaks, indicating a greater uniformity and homogeneity of the surfaces. The optical properties were studied to determine laser effect. The results of optical tests of these thin films showed that the photoluminescence spectra and absorption s

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Nov 20 2015
Journal Name
Iraqi Journal Of Science
New Approach for Determination of Oxonium Ion in Inorganic Acids by Quenched Fluorescence of Analytically Interested Species via the Liberated Bromine Using Continuous Flow Injection Laser Diode Fluorimeter Analyser
...Show More Authors

A new method is characterized by simplicity, accuracy and speed for determination of Oxonuim ion in ionisable inorganic acid such as hydrochloric (0.1 - 10) ,Sulphuric ( 0.1 - 6 ),nitric ( 0.1 - 10 ), perchloric ( 0.1 - 7 ), acetic (0.1 - 100 ) and phosphoric ( 0.1 - 30 ) ( mMol.L-1 )acids. By continuous flow injection analysis. The proposed method was based on generation of bromine from the Bro-3-Br-- H3O+. Bromine reacts with fluorescein to quenches the fluorescence . A sample volume no.1 (31μl) and no.2 (35μl) were used with flow rate of 0.95 mL.min-1 using H2O line no.1as carrier stream and 1.3 mL.min-1 using fluorescein sodium salt line no.2. Linear regression of the concentration ( mMol.L-1 ) Vs quenched fluorescence gives a correla

... Show More
View Publication
Publication Date
Tue Nov 15 2022
Journal Name
Journal Of Mechanical Engineering
Enhancement of Mechanical Properties and Corrosion Resistance of Cast Iron Alloy Using CO<inf>2</inf> Laser Surface Treatment
...Show More Authors

This work aimed to study the effect of laser surface treatment on the mechanical characteristics and corrosion behaviour of grey cast iron type A159. Many technical applications used conventional surface treatment, but laser surface hardening has recently been used to enhance the surface properties of many alloys. The mechanical characteristics, including microstructure, microhardness, and wear resistance of A159 grey cast iron, were studied, in addition to corrosion behaviour. The experimental laser parameters in this work were 0.9, 1.2, and 1.5 KW power with continuous wave carbon dioxide lasers with scanning speeds of 10 and 12 mm/s were used. The results found that phase-transitional alterations in microstructure were influenced by lase

... Show More
Preview PDF
Scopus (2)
Scopus
Publication Date
Mon May 01 2017
Journal Name
Nano Hybrids And Composites
White Light Generation from Electroluminescence Devices Using TPD:PMMA/QDs/Alq&lt;sub&gt;3&lt;/sub&gt;
...Show More Authors

Quantum dots of CdSe, CdS and ZnS QDs were prepared by chemical reaction and used to fabricate organic quantum dot hybrid junction device. QD-LEDs were fabricated using layers of ITO/TPD: PMMA/CdSe/Alq3, ITO/TPD: PMMA/CdS/Alq3 and ITO/TPD: PMMA/ZnS/Alq3 devices which prepared by phase segregation method. The hybrid white light emitting devices consists, of three-layers deposited successively on the ITO glass substrate; the first layer was of N, N’-bis (3-methylphenyl)-N, N’-bis (phenyl) benzidine (TPD) polymer mixed with polymethyl methacrylate (PMMA) polymers. The second layer was QDs while the third layer was tris (8-hydroxyquinoline) aluminium (Alq3

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Manufacturing Zener diode using ZnO-CuO-ZnO/Si structures deposited laser induced plasma technique
...Show More Authors

        In this paper Zener diode was manufactured using ZnO-CuO-ZnO/Si heterojunction structure that used laser induced plasma technique to prepare the nanofilms. Six samples were prepared with a different number of laser pulses, started with 200 to 600 pulses on ZnO tablet with fixed the number of laser pulses on CuO tablet at 300 pulses. The pulse energy of laser deposited was 900mJ using ZnO tablet and 600mJ using CuO tablet. All prepared films shown good behavior as Zener diode when using porous silicon as substrate.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Establish Growth Curve in Light of Body Mass Index for Infertile Women in Baghdad City
...Show More Authors

Objective: To establish growth curve for a sample of infertile women and to assess Body Mass Index.
Methodology: Non-probability (purposive sample) of (100) infertile women, who visit Kamal Al-Samaraee
Hospital/ fertility and IVF center . The data are collected through the use of constructed questionnaire, which
consists of two parts. Part 1: consists of (5) items about demographic characteristics, part 2: consists of (4) items
about reproductive status, descriptive statistical analysis procedures (frequency, percentage, Contingency
coefficients, polynomial cube order).
Results: Revealed that the infertile women in the study group had decrease in their Body Mass Index with aging
(with increase of infertility duration

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and Characterization of Poly (D,L-Lactide-Co-Glycolide) Microspheres for Controlled Release of KSL Peptide
...Show More Authors

The purpose of this research was to prepare, characterize, and evaluate the new antimicrobial peptide  KSL peptide encapsulated in poly(D,L-lactide-co-glycolide) (PLGA)composite microspheres. KSL was loaded in poly(acryloyl hydroxyethyl) starch (acHES) micropar-ticles, and then the peptide-containing microparticles were encapsulated in the PLGA matrix by a solvent extraction /evaporation method.

 KSL-loaded PLGA microspheres were also prepared without the starch hydrogel microparticle microspheres for comparison study. KSL peptide microspheres were characterized for drug content, surface morphology, microspheres size determination, polymers stability , in vitro microspheres degradation and in vitro release. KSL peptide

... Show More
View Publication Preview PDF
Crossref