Preferred Language
Articles
/
RxYtU4cBVTCNdQwCfUU4
The reliability of using light therapy compared with LASER in pain reduction of temporomandibular disorders: a randomized controlled trial
...Show More Authors
Abstract<sec> <title>Background

Temporomandibular Disorders (TMD) refer to a group of symptoms where pain is the most leading cause to demand a treatment by the patient. Light therapies are of great importance at current times due to its biosafety and non-invasive quality when used for the management of TMD symptoms. This study aimed to evaluate the efficacy of red LED light with low-level LASER in treating TMD patients.

Materials and methods

A double-blind randomized clinical study was conducted and included 60 patients along 3 groups (20 for each group) presented with myofascial pain related to TMD. Patients were randomly divided into 3 groups. Group A were managed by applying the LED light device into the trigger points without switching the device on. A red LED light was given to group B for 5 min at the tender muscles. Group C were treated by using low-level LASER therapy for 30 s. Patients were evaluated for any improvements regarding the pain score, presence of trigger points, and trismus along 4 visits (1 week interval between each visit). Any side effects related to the 2 devices were also assessed.

Results

Both group B and C patients showed a statistically significant improvement in the pain value (P < 0.05) at the 3rd and 4th visits when compared to group A. Regarding tenderness, there was a reduction in the number of trigger points in both study groups; however, the results were insignificant in group B. Statistics showed insignificant differences between group B & C patients regarding pain and number of trigger points at all visits (P > 0.05).

Conclusion

Both LED light and LASER therapies could effectively relieve pain associated with myogenic TMD as there were no important differences between their outcomes. However, the biosafety and lower cost of the LED light device compared to the LASER should also be considered.

Trial Registration This clinical trial was prospectively registered (TCTR ID: TCTR20190507002) on 07/05/2019. URL: http://www.thaiclinicaltrials.org/show/TCTR20190507002

Crossref
View Publication
Publication Date
Fri Jun 03 2016
Journal Name
Iraqi Medical Journal
EVALUATION OF PATIENTS WITH CARPAL TUNNEL SYNDROME TREATED BY MINIMAL PALMAR INCISION (A PRELIMINARY STUDY)
...Show More Authors

Background : Carpal tunnel syndrome (CTS) is the most common entrapment neuropathy of upper extremities and Open carpal tunnel release is the most frequent surgical procedure and the gold standard for cases that do not respond to conservative treatment. Aims :This study is used to evaluate the functional outcome of limited palmar mini-incision of carpal tunnel release. This study aims to determine the safety and symptomatic and functional efficacy of median nerve decompression with limited incision in carpal tunnel syndrome surgery. Patients and methods:Carpal tunnel release with a 1.5-2 cm limited palmar incision was performed on 20 patients. Patients were evaluated initially at one month after treatment according to symptom severity

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 04 2023
Journal Name
Frontiers In Chemestry
Thermal and flow performance analysis of a concentrated linear Fresnel solar collector with transverse ribs
...Show More Authors

This article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain abs

... Show More
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Jan 23 2020
Journal Name
Acoustics Australia
Absorption Coefficient of a Double-Layer Inhomogeneous Micro-perforated Panel Backed with Multiple Cavity Depths
...Show More Authors

Double-layer micro-perforated panels (MPPs) have been studied extensively as sound absorption systems to increase the absorption performance of single-layer MPPs. However, existing proposed models indicate that there is still room for improvement regarding the frequency bands of absorption for the double-layer MPP. This study presents a double-layer MPP formed with two single MPPs with inhomogeneous perforation backed by multiple cavities of varying depths. The theoretical formulation is developed using the electrical equivalent circuit method to calculate the absorption coefficient under a normal incident sound. The simulation results show that the proposed model can produce absorption coefficient with wider absorption bandwidth compared w

... Show More
View Publication
Scopus (21)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Mon Jun 30 2025
Journal Name
Scripta Medica
Case Report: A Rare Presentation of Sigmoid Volvulus During Pregnancy With an Integrative Postoperative Approach
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Oct 16 2021
Journal Name
Energies
Performance Analysis of a Solar Cooling System with Equal and Unequal Adsorption/Desorption Operating Time
...Show More Authors

In solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational

... Show More
View Publication
Scopus (11)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Tue Oct 07 2003
Journal Name
University Of Baghdad
A STUDY ON SOLVENT EXTRACTION OF HOLMIUM (III) WITH SUDAN BLACK B REAGENT (M.Sc. Thesis)
...Show More Authors

Preview PDF
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Study of Some Mechanical Properties for a Polymer Material Reinforcement with Chip or Powder Copper
...Show More Authors

In this paper, chip and powder copper are used as reinforcing phase in polyester matrix to form composites. Mechanical properties such as flexural strength and impact test of polymer reinforcement copper (powder and chip) were done, the maximum flexural strength for the polymer reinforcement with copper (powder and chip) are (85.13 Mpa) and (50.08 Mpa) respectively was obtained, while the maximum observation energy of the impact test for the polymer reinforcement with copper (powder and chip) are (0.85 J) and (0.4 J) respectively  

View Publication Preview PDF
Crossref
Publication Date
Wed Aug 21 2019
Journal Name
Al-khwarizmi Engineering Journal
Design and Optimization of a Surface-Mounted Permanent-Magnet Linear Synchronous Motor with Maxwell ANSYS
...Show More Authors

Linear motor offers several features in many applications that require linear motion. Nevertheless, the presence of cogging force can deteriorate the thrust of a permanent magnet linear motor. Using several methodologies, a design of synchronous single sided linear iron-core motor was proposed. According to exact formulas with surface-mounted magnets and concentrated winding specification, which are relying on geometrical parameters. Two-dimensional performance analysis of the designed model and its multi-objective optimization were accomplished as a method to reduce the motor cogging force using MAXWELL ANSYS. The optimum model design results showed that the maximum force ripple was approximatrly reduced by 81.24%compared to the origina

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Bearing Capacity of a Strip Model Footing on Loose Sand Reinforced With Pomegranate Sticks Mat
...Show More Authors

A series of laboratory model tests has been carried out to investigate the using of pomegranate sticks mat as reinforcement to increase the bearing capacity of footing on loose sand. The influence of depth and length of pomegranate sticks layer was examined. In the present research single layer of pomegranate sticks reinforcement was used to strengthen the loose sand stratum beneath the strip footing. The dimensions of the used foundation were 4*20 cm. The reinforcement layer has been embedded at depth 2, 4 and 8 cm under surcharge stresses . Reinforcing layer with length of 8 and 16 cm were used. The final model test results indicated that the inclusion of pomegranate sticks reinforcement is very effective in improvement the loading cap

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Nov 13 2012
Journal Name
Wireless Personal Communications
Design and Implementation of a Scalable RFID-Based Attendance System with an Intelligent Scheduling Technique
...Show More Authors

View Publication
Scopus (17)
Crossref (7)
Scopus Clarivate Crossref