Measurements of radon gas concentrations were carried out for 12 soil samples at 3 sampling depths (surface, 5 cm and 10 cm) collected from (4) locations in south Baghdad suburbs (Bu'aitha) using solid state nuclear track detector CR-39 and sealed can technique. Radon concentrations for surface samples were ranged from 402.2 to 1538.4 Bq.m-3 with an average 994.4 Bq.m-3. Whereas, radon concentration was ranged from 813.1to 2050.4 Bq.m-3 and from 1309.8 to 4626. 1Bq.m-3 with an average values of 1359.8 Bq.m-3 and 2338.3 Bq.m-3 for 5 cm and 10 cm depths respectively. Maximum radon level was found at the location near to the river (site S4) while the minimum radon level was f
... Show MoreBackground: the early identification of developmental disabilities allows intervention at the earliest possible point to
improve the developmental potential.
Objective: Identify the scope of knowledge of nurses toward signs of gross motor delay for children and its relation to
their demographic characteristics.
Methodology: A descriptive study design was conducted at (18) primary health care centers in first of the primary
health care sector of Alhawija District in Kirkuk Governorate. This study started from September 2010 to the end of
January 2011, in order to identify the level of nurses' knowledge toward signs of gross motor delay for children in
primary health care centers. Non probability (purposive) sample of
Knowledge of permeability is critical for developing an effective reservoir description. Permeability data may be calculated from well tests, cores and logs. Normally, using well log data to derive estimates of permeability is the lowest cost method. This paper will focus on the evaluation of formation permeability in un-cored intervals for Abughirab field/Asmari reservoir in Iraq from core and well log data. Hydraulic flow unit (HFU) concept is strongly related to the flow zone indicator (FZI) which is a function of the reservoir quality index (RQI). Both measures are based on porosity and permeability of cores. It is assumed that samples with similar FZI values belong to the same HFU. A generated method is also used to calculate permea
... Show MoreThis research deals with the study of top soil electrical conductive regions located within Baghdad City. The research included measuring the dissolved soil material extraction Electrical Conductivity (EC) with an aqueous solution for the top (0-30 cm) soil layer of the study area. As the electrical conductivity values increase by increasing the amount of dissolved salts in principle, we can consider that the aim of this research is to predict the amount and distribution of (soil contamination with salts) which is represented by the (Salt Index), this factor calculated for each soil representative sample taken from the region with a depth of (30 cm). Laboratory (EC) test values measured by the use of solutions (EC) digital meter for the ex
... Show MoreOrganic soil is problematic soils in geotechnical engineering due to its properties, as it is characterized by high compressibility and low bearing capacity. Therefore, several geotechnical techniques tried to stabilize and improve this soil type. In this study, sodium silicate was used to stabilize sand dune columns. The best sodium silicate concentration (9%) was used, and the stabilized sand dune columns were cured for seven days. The results for this soil were extracted using a numerical analysis program (Plaxis 3D, 2020).In the case of studying the effect of (L/D) (where ‘’L” and ‘’D’’ length and diameter of sand dune columns) of a single column of sand dunes stabilized with sodium silicate with a diff
... Show MoreIn this study a concentration of uranium was measured for twenty two samples of soil distributed in many regions (algolan, almoalmeen, alaskary and nasal streets) from Falluja Cityin AL-Anbar Governorate in addition to other region (alandlos street) as a back ground on the Falluja City that there is no military operations happened on it. The uranium concentrations in soil samples measured by using fission tracks registration in (PM-355) track detector that caused by the bombardment of (U) with thermal neutrons from (241Am-Be) neutron source that has flux of (5×103n cm-2 s-1). The concentrations values were calculated by a comparison with standard samples. The results shows that the uranium concentrations algolan street varies from(1.
... Show MoreAir pollution is very important topic for those interested in studying the environment because of its importance and the damage caused by it to human, animal and plant life. This research addresses the concept of air pollution, its causes, and its danger, and sheds light on the influence of climate elements on environmental pollution and the effect of temperature, rain, humidity, wind direction and speed, and atmospheric pressure on the increase or decrease of air pollution. This research discusses the sources of air pollution, including natural ones, including dust, smoke resulting from fires, erupting volcanoes, and others, including those resulting from human uses such as the use of fuel and others. The research addressed the dam
... Show More