This study illustrates effect of cold plasma CAP on the mineral blood components in vivo. the mineral blood component (Ca, Na, Cl, K and Fe) are used. Floating Electrode-Dielectric Barrier Discharge (FE-DBD) system of probe diameter 4cm is used for this purpose, and variable voltage (0-20) kV and variable frequency (0-30) kHz, the output power was ranged from (10 - 70) W. the effect of cold atmospheric plasma on mineral blood is studied with different exposure durations (30,45,60) sec. As the plasma exposure duration increases, the calcium, potassium and iron components in the blood increased, while The sodium and chlorine elements decreased. These results give an indication of the cold plasma receptor to be used to treat many diseases related to mineral blood components.
High-intensity laser-produced plasma has been extensively investigated in many studies. In this demonstration, a new spectral range was observed in the resulted spectra from the laser-plasma interaction, which opens up new discussions for new light source generation. Moreover, the characterizations of plasma have been improved through the interaction process of laser-plasma. Three types of laser were incorporated in the measurements, continuous-wave CW He-Ne laser, CW diode green laser, pulse Nd: YAG laser. As the plasma system, DC glow discharge plasma under the vacuum chamber was considered in this research. The plasma spectral peaks were evaluated, where they refer to Nitrogen gas. The results indicated that the
... Show MoreBackground: Environmental chemicals are thought to
adversely affect human reproductive function.
Objective : To estimate the concentration of cadmium(Cd)
, lead ( Pb ) and Zinc ( Zn ) in serum and seminal plasma
among infertile men .
Methods: A sample of 70 infertile men was investigated.
The relationship of trace elements concentration in serum and
seminal plasma was studied in relation to sperm density,
motility and sperm count.
Results: Except for Zinc the concentration of (Pb) and (Cd)
were generally higher in serum than in seminal plasma. The
mean concentration of (Zn) in seminal plasma was more than
25 times higher than in serum There were no statistical
significant differences observed in the
The objective of this study was to investigate the effect of Royal jelly RJ on morphology and motility of mice sperms. Sperms were collected from the cauda region of the epididymis of each 10 mice from the treatment and control groups. Direct activation techniques and evaluation of sperm morphology were carried out. Dhino microscope was used for sperm measurement. The inspection was carried out in Salamatic laboratory for pathological analysis in 2015.The result revealed that all of the sperm function parameters registered significant activation in the treatment group. There was a significant increase in both the percentage of the sperm motility grade A and the progressive motility (A+B) of the treatment gr
... Show MoreThe importance of the current study lies in the importance of the Tax policy that being considered one of the most important tools working on fulfilling the social, financial and economic goals and improving the investment environment in the country to become having the ability to activate the national economy. The current study has referred that ( Has the tax planning practiced by the Iraqi contribution companies led to increase the far-term tax outcome through getting benefit of the monetary funds and expansion in&nbs
... Show MoreBack ground: In the present study Pinealoctomy
was used to study the sympathetic innervations of
the pineal gland by the superior cervical ganglion
(SCG) of the albino rat.
Objective: Following Pinealoctomy, it is
expected to observe the Chromatolysis reaction in
some neurons of the SCG if they were to innervate
the pineal gland (i.e. retrograde Chromatolysis
changes).
Methods: Fifty albino rats were used in this study,
Pinealoctomy was done, then after a different time
interval ganglionectomy was done, in order to
study the Chromatolysis in their cell body.
Result: The present study has demonstrated that
the most obvious Chromatolysis reaction in the
neurons which innervate the pineal gland a
In this work; Silicon dioxide (SiO2) were fabricated by pulsed
laser ablation (PLA). The electron temperature was calculated by
reading the data of I-V curve of Langmuir probe which was
employed as a diagnostic technique for measuring plasma properties.
Pulsed Nd:YA Glaser was used for measuring the electron
temperature of SiO2 plasma plume under vacuum environment with
varying both pressure and axial distance from the target surface. The
electron temperature has been measured experimentally and the
effects of each of pressure and Langmuir probe distance from the
target were studied. An inverse relationship between electron
temperature and both pressure and axial distance was observed.
Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro
... Show More