Preferred Language
Articles
/
RIbNtoYBIXToZYALb7Pr
Post-fire serviceability and residual strength of composite post-tensioned concrete T-beams
...Show More Authors
Abstract<p>In this study, the response of ten composite post-tensioned concrete beams topped by a reinforced concrete deck with adequate reinforcing shear connectors is investigated. Depending on the concrete compressive strength of the deck slab (20, 30, and 40 MPa), beams are grouped into three categories. Seven of these beams are exposed to a fire attack of 700 and 800 °C temperature simultaneously with or without the presence of a uniformly distributed sustained static loading. After cooling back to ambient temperature, these composite beams are loaded up to failure, using a force control module, by monotonic static loading in a four-point-bending setup with two symmetrical concentrated loads applied in the middle third of the effective span. The objectives of this study include investigating the behavior of the composite prestressed concrete beams under and after the exposure to a direct fire flame, as well as finding their residual load-carrying capacity. Tests demonstrate significant deteriorations caused by exposure to high temperatures associated with the increase of the member’s camber. The increase of the midspan camber after heating exposure reached approximately 200%. On the other hand, the 1-h steady-state exposure of test specimens to temperatures of 700 and 800 °C led to reduce the load-carrying capacity of the heat-deteriorated beams up to 45% and 54%, respectively.</p>
Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Properties of High Performance Concrete
...Show More Authors

The research deals with a new type of high-performance concrete with improved physical properties, which was prepared by using metal additives minutes (Metakaolin) and by studing their impact on the properties of mortar and concrete high-performance through destructive and non destructive tests. This type of concrete is used broadly in public buildings and in other structures . The research involved a number of experiments such as finding the activity index of burned at a temperature of 750 º C according to the standard ( ASTM C-311/03), as well as casting models for the cubic mortar mixtures and concrete containers at different rates of metakaolin ranging between (5% - 20%) as an added part to the cement mix to get a high- compressive

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Preparation of unsaturated polyester/nano ceramic composite and study electric, thermal and mechanical properties
...Show More Authors

The composites were manufactured and study the effect of addition of filler (nanoparticles SiO2 treated with silane) at different weight ratios (1, 2, 3, 4 and 5) %, on electrical, mechanical and thermal properties. Materials were mixed with each other using an ultrasound, and then pour the mixture into the molds to suit all measurements. The electrical characteristics were studied within a range of frequencies (50-1M) Hz at room temperature, where the best results were shown at the fill ratio (1%), and thermal properties at (X=3 %), the mechanical properties at the filler ratio (2%).

View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Study of Fatigue and Bending Properties For Epoxy / Kevlar - Glass Fibers and Hybrid Composite
...Show More Authors

In this research a study of the effect of quality, sequential and directional layers for three types of fibers are:(Kevlar fibers-49 woven roving and E- glass fiber woven roving and random) on the fatigue property using epoxy as matrix. The test specimens were prepared by hand lay-up method the epoxy resin used as a matrix type (Quick mast 105) in prepared material composit . Sinusoidal wave which is formed of variable stress amplitudes at 15 Hz cycles was employed in the fatigue test ( 10 mm )and (15mm) value 0f deflection arrival to numbers of cycle failure limit, by rotary bending method by ( S-N) curves this curves has been determined ( life , limit and fa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 31 2017
Journal Name
Journal Of Engineering
Experimental and Numerical Investigation of Hyper Composite Plate Structure Under Thermal and Mechanical Loadings
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Engineering
Punching Shear Strength of Self Compacted Ferrocement Slabs
...Show More Authors

This study aims to investigate the behavior and strength of self-compacted ferrocement slabs under punching shear load. Experimental results of thirteen square ferrocement slabs of 500×500 mm simply supported on all edges are presented.  The main parameters investigated include the volume fraction of reinforcement, slab thickness and size of load-bearing plate. The load deflection and cracking characteristics of the tested slabs are studied and compared.  The test results showed that the volume fraction of wire mesh has significant effect on both ultimate load and displacement. The increase of slab thickness leads to decrease in deflection values and increase in stiffness of slabs. Both ductility and stiffness increase as the

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 20 2019
Journal Name
Political Sciences Journal
Article Structural violence: A study In Johann Galtung's theory of explanation he violence t
...Show More Authors

This study deals with the subject of violence, but from another perspective, it has not been emphasized in contemporary studies of violence in Arabic and raqi universities, which is the structural or institutional aspect of violence. Traditional studies have focused their analysis of violence on the direct side the violence, The other side of the violence is the hidden violence, which is characterized by a lack of clarity of the underlying factors and its effects are not arises, which makes it the most serious violence, which requires a deep research into the social, political, economic, cultural and psychological structure of society (individuals and institutions). This study was based on the theory of the Norwegian scientist (J

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 16 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Theoretical Calculations For Sputtering Yield of Iron Bombarding by (H, D, T, He) Ions
...Show More Authors

Extended calculations for  sputtering yield   through bombed Iron – target   by ( H,D ,T ,He )  ions plasma are accomplished .The calculations include changing the  input    parameters  :    the energy  of ( H,D ,T ,He ) ions plasma, the hit target angle of Iron, change  atomic   mass  of incident ion. The program TRIM is used to accomplish these calculations. The results     show   that   sputtering   yield is   directly   dependent   on   these parameters. It can   change the incident angle of ( H,D ,T ,He ) ions   and energy&n

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 16 2025
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Temperature and Frequency on the Dielectric Properties of PVC/MnCl2 Composite
...Show More Authors

View Publication
Publication Date
Sun Mar 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of dispensing method and curing modes on the microleakage of composite resins
...Show More Authors

Background: Vibration decreases the viscosity of composite, making it flow and readily fit the walls of the cavity. This study is initiated to see how this improved adaptation of the composite resin to the cavity walls will affect microleakage using different curing modes

Materials and methods: Standard Class V cavities were prepared on the buccal surface of sixty extracted premolars. Teeth were randomly assigned into two groups (n=30) according to the composite condensation (vibration and conventional) technique, then subdivided into three subgroups (n=10) according to light curing modes (LED-Ramp, LED-Fast and Halogen Continuous modes). Cavities were etched and bonded with Single Bond Universal

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Sun Aug 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Temperature and Frequency on the Dielectric Properties of PVC/MnCl2 Composite
...Show More Authors

       The dielectric properties of polyvinyl chloride (PVC)-MnCl2 composite were studied by using the impedance technique. The measurements were carried out as a function of frequency in the range from 10 Hz to 13 MHz and temperature range from 27oC to 55oC. Using a composite of 20 wt. % MnCl2 by weight, it was found that the dielectric constants and the dielectric loss of the prepared films increase with the increasing temperature at law frequency and the enhancement of the ionic conduction which is confirmed by the increase the of AC. conductivity and the decrease of the activation energy of the conduction mechanism at high applied frequency. The observed relaxation and polarization effects of composite a

... Show More
View Publication Preview PDF