This paper presents a parametric audio compression scheme intended for scalable audio coding applications, and is particularly well suited for operation at low rates, in the vicinity of 5 to 32 Kbps. The model consists of two complementary components: Sines plus Noise (SN). The principal component of the system is an. overlap-add analysis-by-synthesis sinusoidal model based on conjugate matching pursuits. Perceptual information about human hearing is explicitly included into the model by psychoacoustically weighting the pursuit metric. Once analyzed, SN parameters are efficiently quantized and coded. Our informal listening tests demonstrated that our coder gave competitive performance to the-state-of-the- art HelixTM Producer Plus 9 from
... Show Morethe research goal is preparing a list of standard criteria and quality controls for information technology applications to serve the Holy Quran.
To achieve this goal, the researcher has built a list of criteria according to the following steps:
First - identify the key areas covered by the whole list which are:
1 – Standards of system building and implementing with the operating screens.
2 – Standards of display forms including audio and video presentation.
3 – Standards which are related to the program philosophy.
4 - Standards which are related to the program objectives.
... Show MoreAbstract
The study aims to identify the extent to which the applied colleges at the University of Technology and Applied Sciences meet the comprehensive quality standards in light of the national education strategy for the 2040 Vision in the Sultanate of Oman. To do this, the researchers used the descriptive approach. They used a questionnaire as a tool for data collection that was applied to (237) administrators, academics, and support functions. The study found that the extent to which the applied colleges at the University of Technology and Applied Sciences meet the comprehensive quality standards in the light of the National Education Strategy 2040 in the Sultanate of Oman recorded a high range. The study als
... Show MoreThe assessment of a river water’ quality is an essential procedure of monitor programs and isused to collect basic environmental data. The management of integrated water resources in asustainable method is also necessary to allow future generations to meet their water needs. Themain objective of this research is to assess the effect of the Diyala River on Tigris River waterquality using Geographic Information System (GIS) technique. Water samples have beencollected monthly from November 2017 to April 2018 from four selected locations in Tigris andDiyala Rivers using the grab sampling method. Fourteen parameters were studied which areTurbidity, pH, Dissolved Oxygen, Biological Oxygen Demand, Electrical Conductivity, TotalDissolved Solids,
... Show MoreThis study aims to explore the potential mediation role of person-centeredness between the effects of the work environment and nurse reported quality and patient safety. A quantitative cross-sectional survey collected data from 1055 nurses, working in medical and surgical units, in twelve Malaysian private hospitals. The data collection used structured questionnaires. The Hayes macro explored the mediation effect of person-centeredness between the associations of work environment dimensions and care outcomes, controlling nurses’ demographics and practice characteristics. A total of 652 nurses responded completely to the survey (61.8% response rate). About 47.7% of nurses worked 7-h shifts, and 37.0% were assigned more than 15 pati
... Show MoreWe wanted to find out how selenium (Se) affects broiler chicken performance, meat physicochemical properties, and selenium deposition in the tissues of broilers. Each of the 96 experimental pens had 30 chickens and included a total of 2,880 one-day-old broilers (Cobb 500 strain). A factorial design of four-by-three (SY + SS) and eight replicates (SY + SS) was used for the 12 experimental treatments, with selenium levels ranging from 0.15 to 0.60 ppm and organic (SY) or inorganic (SS) sources of selenium and their relationship (SY + SS). There were no differences in performance (P > 0.05) across Se levels or sources. 106 g/day of ADFI, 63 g/day of ADG, and 1.6844 kg/kg of FCR were found to be the averaging values for these three parameters:
... Show MoreUnmanned aerial vehicles (UAVs) can provide valuable spatial information products for many projects across a wide range of applications. One of the major challenges in this discipline is the quality of positioning accuracy of the resulting mapping products in professional photogrammetric projects. This is especially true when using low-cost UAV systems equipped with GNSS receivers for navigation. In this study, the influence of UAV flight direction and camera orientation on positioning accuracy in an urban area on the west bank of the Euphrates river in Iraq was investigated. Positioning accuracy was tested in this study with different flight directions and camera orientation settings using a UAV autopilot app (Pix4Dcapture software
... Show More