Preferred Language
Articles
/
QxbGDIcBVTCNdQwCfjMM
Solving high sulfate content of sand used in concrete by magnetic water process
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied.
Results show that high similarity between water phantom and actual planning for th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jul 22 2020
Journal Name
University Of Baghdad
Feasibility of Water Sink-Based Gas Flooding to Enhance Oil Recovery in North Rumaila Oil Field
...Show More Authors

Publication Date
Sun Jan 16 2022
Journal Name
Iraqi Journal Of Science
A New Chromogenic Reagent for Determination of Copper (II) in Water Samples Using Flow injection-Technique.
...Show More Authors

A new flow injection spectrophotometric method is described for the determination of copper ion Cu(II) in water samples (tap water and river water).The proposed method based on the formation of red complex [Cu(L)2(NO3)2] which has a maximum absorption at λmax=490 nm. Linear range for Cu (II) was from 5-70μg/mL with detection limit 2.55μg/mL. The effect of physical and chemical parameters were evaluated .The proposed method was applied successfully for determination of copper (II) in the tap and river water. [Cu(L)2(NO3)2] complex was prepared in a (2:1) mole ratio as ( reagent: copper (II)).The analytical reagent formed by reaction of thymol with 4-aminoantipyrine at room temperature. The metal complex was characterized by IR, UV-Visi

... Show More
View Publication
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Anti-Microbial Effect Of Different Time’sexposureofozonized Gas And Ozonized Water Onperiodontalpathogens (In Vitro Study)
...Show More Authors

Background: the oral cavity is consider to be an open ecosystem, with the balance between the microorganism’s entrance and the defenses of the host. The initiation of periodontitis has been associated with restricted kinds of anaerobic bacteria, such as Aggregatibacter actinomycetemcomitans (A.a) and Porphyromonas gingivalis (P.g) in plaque subgingivally. Ozone has a biological effects on bacteria due to oxidation of bio-molecules and its toxins. The aim is to determine and compare the antimicrobial effect of gaseous ozone and ozonized water on the growth of isolated anaerobic bacteria (A.a and P.g) when exposed to different time intervals. Materials and methods:This experiment is done byozone generator OLYMPIC- III(600mg/hr) to gene

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue May 01 2018
Journal Name
Environmental Technology & Innovation
Cultivation of Nannochloropsis oculata and Isochrysis galbana microalgae in produced water for bioremediation and biomass production
...Show More Authors

Scopus (69)
Crossref (66)
Scopus Clarivate Crossref
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Enhancement in Lubricating, Rheological, and Filtration Properties of Unweighted Water-Based Mud Using XC Polymer NPs
...Show More Authors

In this research, an enhancement in lubricating, rheological, and filtration properties of unweighted water-based mud is fundamentally investigated using XC polymer NPs with 0.2gm, 0.5gm, 1gm, 2gm, and 4gm concentrations. Bentonite, that had been used in the preparation of unweighted water-based mud, was characterized using XRF-1800 Sequential X-ray Fluorescence Spectrometer, XRD-6100/7000 X-ray Diffractometer, and Malvern Mastersizer 2000 particle size analyzer, respectively. Lubricating, rheology and filtration properties of unweighted water-based mud were measured at room temperature (35°C) using OFITE EP and Lubricity Tester, OFITE Model 900 Viscometer, and OFITE Low-Pressure Filter Press, respectively. XC Polymer N

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of Engineering
Experimental Study of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit Using RSM Technique
...Show More Authors

The distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Aug 30 2018
Journal Name
Iraqi Journal Of Science
Effect of Discharged Industrial Water from Tannery Plants in Nahrawan on Groundwater and Brick Quarries Soil
...Show More Authors

The discharged water from tannery plants is main source for pollution of soil and groundwater, especially in Nahrawan area. Water samples is collected from 10 sites of wells, discharged water and from using water in different levels of tannery and 7 soil samples from different sites inside factories area and outside it. The results shown that pH for samples of wells and discharged water were within allowable limits between 6.5- 8.5, except the value of pH recorded in the discharged water sample (after the addition of calcium hydroxide) was 12.8, as well as reached the highest value of total dissolved salts (TDS) 7800 ppm in same samples. It also reached its highest value of electrical conductivity (EC) 8200 μS/cm. The results showed tha

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 04 2024
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Impact of Performance Auditing Process Pursuant to the Programs and Policies Guide in improving the health insurance Prosperity: applied research in the Iraqi General Insurance Company
...Show More Authors

Abstract

              The research’s goal lies in demonstrating the impact of the Federal Financial Supervision Endowment through the process of auditing the performance of the entities subject to its audit as to improve the performance of these entities, especially if the performance audit method is one of the newly applied methods that are compatible with the standards issued by the International Organization of Financial Supervision and Accounting Institutions which is the method of auditing performance according to the performance evaluation guide for programs and policies issued by the Federal Office of Financial Supervision.

 T

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 30 2021
Journal Name
Iraqi Journal Of Science
Measurement of Pollution Level with Particulate Matter in Babylon Concrete Plant and Evaluation of Oxidative Stress and Hematological Profile of Plant Workers
...Show More Authors

The impact of exposure to different sizes of particulate matter (PM1, PM2.5, PM7, and PM10) was evaluated in  Babylon concrete plant workers who had been exposed to concrete dust for at least 10 years.  The effects of  these particles on the hematological parameters, malondialdehyde (MDA) levels, and  antioxidant enzymes (catalase and glutathione peroxidase ) were examined. The results exhibited that the levels of PM2.5 and PM10 were higher than the acceptable limits approved by the National Ambient Air Quality Standards (NAAQS). The blood parameters, namely white blood cells (WBC), red blood cell (RBC) and platelets counts, demonstrated non-significant differences between workers exposed to the PM as compared to the control gro

... Show More
Scopus (3)
Scopus Crossref