Preferred Language
Articles
/
Qhev55EBVTCNdQwCAZw7
Application of UV-A light Operating Photoreactor for Green Degradation of Direct Blue 15 through the Photo-Fenton-like process: Effects and Box-Behnken Optimization
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jun 30 2024
Journal Name
Management And Social Perspectives
The Role of Green Target Costing in Improving Supplier Relations
...Show More Authors

This study aims to explain the role of green target costing technique in improving the relationship with suppliers in a sample of industrial companies listed on the Iraq Stock Exchange. The descriptive analytical approach was used, where a questionnaire was designed that included a set of questions that were directed to a sample of 84 individuals including production managers, finance managers, quality managers, and purchasing managers in these companies. The study uses some statistical analyzes such as correlation analysis and regression analysis to analyze the questionnaires. The study finds a positive impact of the green target costing technique on improving the relationship with suppliers. The results indicate that the relation

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Africa Health Research Organization
The anti- Leishmaniasis activity of green synthesis silver oxide nanoparticles
...Show More Authors

View Publication
Scopus (14)
Crossref (6)
Scopus Crossref
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Evaluation of Three Phase Spray Direct Contact Heat Exchanger
...Show More Authors

 

The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as c

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2007
Journal Name
Nephron Clin Pract
Antiglycation and Antioxidant Effect of Carnosine against Glucose Degradation Products in Peritoneal Mesothelial Cells
...Show More Authors

Toxicity with advanced glycation end products (AGEs) is a major problem in uremic patients. Treatment with peritoneal dialysis (PD) exacerbates AGE formation as a result of bioincompatibility of the conventional peritoneal dialysis fluid (PDF). The presence of glucose degradation products (GDPs) in PDF is the main cause of its bioincompatibility. Carnosine is an endogenous dipeptide with a powerful antiglycation/antioxidant activity. In an attempt to improve PDF biocompatibility, we evaluated the effect of carnosine in human peritoneal mesothelial cells (HPMC) incubated with PDF or GDPs in vitro. Methods: HPMC were incubated for short or prolonged time with PDF in the presence or absence of carnosine. Similarly, HPMC were incubated in the s

... Show More
Publication Date
Fri Jun 18 2004
Journal Name
Iraqi Journal Of Laser
Effect of Operating Temperature on Performance of Obliquely Deposited Bi, Sb and Bi-Sb Semimetal Thin Film Laser Detectors
...Show More Authors

Obliquely deposited (70o) Bi, Sb, and Bi-Sb alloy thin films have been prepared by thermal
resistive technique. Structural properties of these films were studied using XRD. Their resistance and
voltage responsivity for Nd:YAG and CO2 laser pulses have been recorded as function of operating
temperature between 10 oC and 120 oC. It was found that the maximum responsivity for these detectors
can be obtained at 75 oC. On the other hand, the dependence of responsivity on the width of detectors was
investigated.

View Publication Preview PDF
Publication Date
Mon Apr 25 2016
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
The role of green taxes in the reduction of environmental pollution- exploratory search- in the GCT.: The role of green taxes in the reduction of environmental pollution- exploratory search- in the GCT.
...Show More Authors

The research aims to identify the concept of green taxes and their role in reducing environmental pollution through the poll of Abnh of taxpayers and employees of the General Authority for taxes totaling 200 individual .autam adoption of the resolution as a tool head for the collection of data and information from the sample and analyzed their responses using a statistical program (spss - 10), and calculating the percentages and the arithmetic mean, standard deviation and research found to a number of conclusions, notably the lack of legislation with the challenges and the difficulty of the existence of a measure or a standard lack of planning for the application of environmental taxes that the state taxation application between the Gene

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Environmental Nanotechnology, Monitoring & Management
Sulfonated polyindole coated magnetic zincoxysulfide ([email protected]@SPID) core/shell nanocatalyst for simultaneous photocatalytic H2 production and BPA degradation
...Show More Authors

Photocatalyst composed of core/shell magnetic zincoxysulfide nanocomposite coated with sulfonated polyindole ([email protected]/SPID) has been prepared and used for simultaneous photocatalytic H2 production and Bisphenol A (BPA) degradation. XRD, FE-SEM, EDX, BET surface area, UV-vis DRS and VSM were used to characterize the synthesized nanocomposites. The photocatalytic performance was evaluated using batch reactor under visible light irradiation. The photocatalytic activity of [email protected]/SPID nanocomposite was revealed to exceed that of [email protected] nanocomposite due to the heterojunctions between SPID and [email protected] species. The results exhibited that the effect of BPA initial concentration was found to be effectual on the improvement

... Show More
Crossref (3)
Crossref
Publication Date
Mon Jun 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Factors Affecting the Extraction Process
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Jun 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Application of Microwave Technology in Demulsification of Water-in-Oil Emulsion for Missan Oil Fields
...Show More Authors

A series of batch demulsification runs were carried out to evaluate the final emulsified water content of emulsion samples after the exposure to microwave. An experimental study was conducted to evaluate the effects of a set of operating variables on the demulsification performance. Several microwave irradiation demulsification runs were carried out at different irradiation powers (700, 800, and 900 watt), using water-in-oil emulsion samples containing different water contents (20-80%, 30-70%, and 50-50%) and salt contents (10000, 20000, and 30000 ppm). It was found that the best separation efficiency was obtained at 900watt, 50% water content and 160 s of irradiation time. Experimental results showed that microwave radiation method can

... Show More
View Publication Preview PDF
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
REMOVAL OF OIL FROM WASTEWATER BY ADVANCED OXIDATION PROCESS / HOMOGENEOUS PROCESS
...Show More Authors

In the present work advanced oxidation process, photo-Fenton (UV/H2O2/Fe+2) system, for the treatment of wastewater contaminated with oil was investigated. The reaction was influenced by the input concentration of hydrogen peroxide H2O2, the initial amount of the iron catalyst Fe+2, pH, temperature and the concentration of oil in the wastewater. The removal efficiency for the system UV/ H2O2/Fe+2 at the optimal conditions and dosage (H2O2 = 400mg/L, Fe+2 = 40mg/L, pH=3, temperature =30o C) for 1000mg/L load was found to be 72%.

View Publication Preview PDF
Crossref (12)
Crossref