Preferred Language
Articles
/
QhdTaJIBVTCNdQwCIa_F
Robust adaptive active disturbance rejection control of an electric furnace using additional continuous sliding mode component
...Show More Authors

The temperature control process of electric heating furnace (EHF) systems is a quite difficult and changeable task owing to non-linearity, time delay, time-varying parameters, and the harsh environment of the furnace. In this paper, a robust temperature control scheme for an EHF system is developed using an adaptive active disturbance rejection control (AADRC) technique with a continuous sliding-mode based component. First, a comprehensive dynamic model is established by using convection laws, in which the EHF systems can be characterized as an uncertain second order system. Second, an adaptive extended state observer (AESO) is utilized to estimate the states of the EHF system and total disturbances, in which the observer gains are updated online by a non-linear observer bandwidth, that is as a function of the observation errors. Moreover, with the help of disturbance estimation, a novel sliding manifold is constructed with parameters adaptively adjusted by a dynamic nonlinear bandwidth function to reduce the impact of high gain problems, especially noise-sensitivity. A continuous sliding-mode (CSM) based component is also designed to handle disturbance estimation errors. Third, the stability of the closed loop system, including the proposed controller and estimator, is mathematically proved using the Lyapunov theorem. Finally, the comparative simulation results show that the proposed method has superior robustness and temperature tracking performance.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
The Calculation and Analysis of the Total Electron Content Over Different Latitudes and Seasons Using the Numerical Trapezoidal and Simpson Methods
...Show More Authors

It has been shown in ionospheric research that calculation of the total electron content (TEC) is an important factor in global navigation system. In this study, TEC calculation was performed over Baghdad city, Iraq, using a combination of two numerical methods called composite Simpson and composite Trapezoidal methods. TEC was calculated using the line integral of the electron density derived from the International reference ionosphere IRI2012 and NeQuick2 models from 70 to 2000 km above the earth surface. The hour of the day and the day number of the year, R12, were chosen as inputs for the calculation techniques to take into account latitudinal, diurnal and seasonal variation of TEC. The results of latitudinal variation of TE

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Sep 28 2025
Journal Name
Journal Of Physical Education
Analysis of Training Load During the Special Preparation and Competition Periods Using Physiological Indicators in U19 Football Players via Smart Bracelet
...Show More Authors

The importance of the study lies in highlighting the role of smartwatches as a modern tool for analyzing training load based on functional indicators, such as heart rate and calorie consumption. This allows coaches to monitor individual players’ responses during different training periods, helping to improve physical performance efficiency and reduce the risk of overload-induced fatigue. The study aimed to analyze calorie consumption at different heart rate levels between the special preparation and competition periods for youth football players, with the goal of determining the effect of physiological adaptation on energy efficiency. To achieve this objective, the researcher adopted the descriptive method due to its suitability f

... Show More
View Publication
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Colloids And Surfaces A: Physicochemical And Engineering Aspects
Studies on membrane stability and extraction of ciprofloxacin from aqueous solution using pickering emulsion liquid membrane stabilized by magnetic nano-Fe2O3
...Show More Authors

View Publication
Scopus (54)
Crossref (48)
Scopus Clarivate Crossref
Publication Date
Fri Jul 19 2024
Journal Name
Applied Science And Engineering Progress
Multicomponent Equilibrium Isotherms and Kinetics Study of Heavy Metals Removal from Aqueous Solutions Using Electrocoagulation Combined with Mordenite Zeolite and Ultrasonication
...Show More Authors

Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon May 01 2023
Journal Name
Chemical Engineering Research And Design
Treatment of petroleum refinery wastewater by electrofenton process using a low cost porous graphite air-diffusion cathode with a novel design
...Show More Authors

View Publication
Scopus (30)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Estimation Of Left Ventricular Ejection Fraction Using Mitral Annular Displacement Derived By Speckle Tracking Echocardiography In Patients With Different Heart Diseases
...Show More Authors

Background: Speckle tracking echocardiography (STE)-derived mitral annular displacement (MAD) utilizes the speckle tracking technique to measure strain vectors, which provides accurate estimates of left ventricular ejection fraction (LVEF).Objectives: To validate the accuracy of mitral annular displacement (MAD), assessed by Speckle Tracking Echocardiography (STE), as a surrogate for determination of left ventricular systolic function in comparison to 2-Dimensions Simpson method in patients with different heart diseases.Methods : This cross-sectional study included patients who referred to outpatient department of Ibn Albitar Center for Cardiac Surgery, Baghdad, Iraq, between October 2012 and April 2013. STE continuously tracked annular

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Science And Research (ijsr)
Height-to-Length Ratio Effect on the Response of Unreinforced Masonry Wall Subjected to Vertical Load Using Detailed-Micro Modeling Approach
...Show More Authors

This paper aimed to investigate the effect of the height-to-length ratio of unreinforced masonry (URM) walls when loaded by a vertical load. The finite element (FE) method was implemented for modeling and analysis of URM wall. In this paper, ABAQUS, FE software with implicit solver was used to model and analysis URM walls subjected to a vertical load. In order to ensure the validity of Detailed Micro Model (DMM) in predicting the behavior of URM walls under vertical load, the results of the proposed model are compared with experimental results. Load-displacement relationship of the proposed numerical model is found of a good agreement with that of the published experimental results. Evidence shows that load-displacement curve obtained fro

... Show More
Publication Date
Sun Sep 06 2015
Journal Name
Baghdad Science Journal
Measurement of radon gas concentration in water and soil samples in AL-Najaf governorate by using nuclear track detector (CR-39)
...Show More Authors

The radon gas concentration in environmental samples soil and water of selected regions in Al-Najaf governorate was measured by using alpha-emitters registrations which are emitted form radon gas in (CR-39) nuclear track detector. The first part is concerned with the determination of radon gas concentration in soil samples, results of measurements indicate that the highest average radon concentration in soil samples was found in (Al-Moalmen) region which was (100.0±7.0 Bq/m3), while the lowest average radon concentration was found in (Al-Askary) region which was (38.5±4.7 Bq/m3), with an average value of (64.23±14.9 Bq/m3) ,the results show that the radon gas concentrations in soil is below the allowed limit from (ICRP) agency which is (

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Economics And Administrative Sciences
The effect of the Iraqi dinar exchange rate on inflation and economic growth using the joint integration methodology "a standard study"
...Show More Authors

The exchange rate is of great importance at the global and local levels alike, as this importance increases with the increasing rates of development of economic relations between countries of the world due to openness and integration into the global economy, expressed by the expansion of the volume of trade and financial relations between countries. The Central Bank of Iraq has set the need to stabilize this price as a goal to reduce inflation rates and reduce them to the internationally accepted rates by using the foreign currency sale window to achieve a balance between the forces of supply and demand for foreign currency and to preserve the value of the Iraqi dinar. The research concluded that the central bank was It has a maj

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Socar Proceedings
Enhanced permeability estimation in non-cored wells using a modified flow zone index-permeability crossplot: a case study of carbonate reservoirs
...Show More Authors

The permeability estimates for the uncored wells and a porosity function adopting a modified flow zone index-permeability crossplot are given in this work. The issues with implementing that approach were mostly crossplots, due to the influence of geological heterogeneity, did not show a clear connection (scatter data). Carbonate reservoir flow units may now be identified and characterized using a new approach, which has been formally confirmed. Due to the comparable distribution and flow of clastic and carbonate rock fluids, this zoning method is most effective for reservoirs with significant primary and secondary porosity. The equations and correlations here are more generalizable since they connect these variables by combining cor

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref