Alzheimer’s disease (AD) is a progressive disorder that affects cognitive brain functions and starts many years before its clinical manifestations. A biomarker that provides a quantitative measure of changes in the brain due to AD in the early stages would be useful for early diagnosis of AD, but this would involve dealing with large numbers of people because up to 50% of dementia sufferers do not receive formal diagnosis. Thus, there is a need for accurate, low-cost, and easy to use biomarkers that could be used to detect AD in its early stages. Potentially, electroencephalogram (EEG) based biomarkers can play a vital role in early diagnosis of AD as they can fulfill these needs. This is a cross-sectional study that aims to demonstrate the usefulness of EEG complexity measures in early AD diagnosis. We have focused on the three complexity methods which have shown the greatest promise in the detection of AD, Tsallis entropy (TsEn), Higuchi Fractal Dimension (HFD), and Lempel-Ziv complexity (LZC) methods. Unlike previous approaches, in this study, the complexity measures are derived from EEG frequency bands (instead of the entire EEG) as EEG activities have significant association with AD and this has led to enhanced performance. The results show that AD patients have significantly lower TsEn, HFD, and LZC values for specific EEG frequency bands and for specific EEG channels and that this information can be used to detect AD with a sensitivity and specificity of more than 90%.
The solvent free oxidation of benzyl alcohol was conducted employing Au and Pd supported catalysts, while utilizing hydrogen peroxide 35% (H2O2) as the oxidant, H2O2 is very cheap, mild, and an environment friendly reagent, which produced water as the only by-product. Various proportions of Au-Pd catalysts on carbon and titanium oxide activated as supports were synthesized through the use of sol immobilization catalyst synthesis technique. Characterization of the synthesized catalysts was performed using X-Ray Diffraction (XRD), Brunauer-Emmett-Teller (BET), Field Emission Scanning Electron Microscopy (FESEM), and Transmission Electron Microscopy (TEM). It was found that the synthesized Au-Pd/ activated carbon catalyst was benef
... Show MoreA total of 200 clinical samples included Burns and Wounds infections were collected from Baghdad Governorate. Results showed that rate all isolates of P. mirabilis was 31(15.5%) and rate of Burns infections was 14 (45%) and rate of wounds infection 17 (55%). Where was diagnostic based on conventional biochemical tests and confirmed by the Vitek-2 Compact system and the specific primer of the16SrRNA gene, the ability of bacterial isolates to biofilm formation to be studied. It's considered an important virulence factor in Incidence of diseases and play important role in increasing resistance to antibiotic of encased bacteria, by two methods Congo Red Agar method and Microtiter Plate method. The Congo Red Agar method showed that most isolates
... Show MoreBackground: This study was conducted to evaluate the hard palate bone density and thickness during 3rd and 4th decades and their relationships with body mass index (BMI) and compositions, to allow more accurate mini-implant placement. Materials and method: Computed tomographic (CT) images were obtained for 60 patients (30 males and 30 females) with age range 20-39 years. The hard palate bone density and thickness were measured at 20 sites at the intersection of five anterioposterior and four mediolateral reference lines with 6 and 3 mm intervals from incisive foramen and mid-palatal suture respectively. Diagnostic scale operates according to the bioelectric impedance analysis principle was used to measure body weight; percentages of body fa
... Show MoreAutorías: Muwafaq Obayes Khudhair, Sanaa Rabeea Abed, Hayder Talib Jasim. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 1, 2023. Artículo de Revista en Dialnet.
A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the
... Show MoreThe study of the validity and probability of failure in solids and structures is highly considered as one of the most incredibly-highlighted study fields in many science and engineering applications, the design analysts must therefore seek to investigate the points where the failing strains may be occurred, the probabilities of which these strains can cause the existing cracks to propagate through the fractured medium considered, and thereafter the solutions by which the analysts can adopt the approachable techniques to reduce/arrest these propagating cracks.In the present study a theoretical investigation upon simply-supported thin plates having surface cracks within their structure is to be accomplished, and the applied impact load to the
... Show More