Background/Objectives: Early and accurate discrimination of neurological conditions, dementia, stroke and healthy aging, remains a critical clinical challenge. Electroencephalography (EEG) is a non-invasive measure of brain dynamics and entropy-based features obtained from multichannel EEG have shown strong discriminative ability. However, existing deep learning approaches do not sufficiently address the combined challenges of small clinical cohorts and high-dimensional entropy feature spaces. In this study, a novel architecture is proposed for multi-class neurological EEG classification under extreme small-sample conditions. Methods: A novel dual-branch Channel-wise Transformer and Attention-Branch Network (EEG-ChTABNet) are pr to classify 19-channel EEG entropy features into three classes (dementia, stroke, healthy control; N = 45; 15 per class). The architecture suggests four new designs. First, the Channel Importance Attention (CIA) block, which adaptively learns to re-weight the importance of electrodes via squeeze-excitation. Second, the dual-branch encoder, which combines the global multi-head self-attention with the local depthwise-separable convolution. Third, the gated sigmoid fusion mechanism. Fourth, the bottleneck residual classification head, to solve overfitting. Eight entropy feature sets: Amplitude-Aware Permutation Entropy (AAPE), Attention Entropy (AttEn), Dispersion Entropy (DisEn), Distribution Entropy (DistrEn), Fluctuation-based Dispersion Entropy (FDispEn), Fuzzy Entropy (FuzEn), Linear Gaussian Estimation of the Conditional Entropy (LinEn), and Symbolic Dynamics (SyDy) were evaluated individually with stratified 5-fold cross-validation on within-fold SMOTE augmentation. Results: EEG-ChTABNet consistently outperformed the baseline Transformer on all 8 feature sets. DisEn and SyDy features yielded peak classification accuracy of 73.3% (AUC: 0.823 and 0.857, respectively) compared to the corresponding baseline of 57.8% and 55.6%. SyDy achieved the best overall AUC of 0.857 and the dementia detection sensitivity was up to 86.7% over multiple feature sets. Conclusions: EEG-ChTABNet shows the effectiveness of channel-adaptive, dual-branch Transformer Designs for EEG-based neurological classification from Small-Sample Entropy Feature Data, and Identifying SyDy and DisEn as the Most Discriminative Feature Representations for Three-Class Neurological EEG Classification.
Information security is a crucial factor when communicating sensitive information between two parties. Steganography is one of the most techniques used for this purpose. This paper aims to enhance the capacity and robustness of hiding information by compressing image data to a small size while maintaining high quality so that the secret information remains invisible and only the sender and recipient can recognize the transmission. Three techniques are employed to conceal color and gray images, the Wavelet Color Process Technique (WCPT), Wavelet Gray Process Technique (WGPT), and Hybrid Gray Process Technique (HGPT). A comparison between the first and second techniques according to quality metrics, Root-Mean-Square Error (RMSE), Compression-
... Show MoreA Multiple System Biometric System Based on ECG Data
This work aims to develop a secure lightweight cipher algorithm for constrained devices. A secure communication among constrained devices is a critical issue during the data transmission from the client to the server devices. Lightweight cipher algorithms are defined as a secure solution for constrained devices that require low computational functions and small memory. In contrast, most lightweight algorithms suffer from the trade-off between complexity and speed in order to produce robust cipher algorithm. The PRESENT cipher has been successfully experimented on as a lightweight cryptography algorithm, which transcends other ciphers in terms of its computational processing that required low complexity operations. The mathematical model of
... Show MoreThis work is concerned with the vibration attenuation of a smart beam interacting with fluid using proportional-derivative PD control and adaptive approximation compensator AAC. The role of the AAC is to improve the PD performance by compensating for unmodelled dynamics using the concept of function approximation technique FAT. The key idea is to represent the unknown parameters using the weighting coefficient and basis function matrices/vectors. The weighting coefficient vector is updated using Lyapunov theory. This controller is applied to a flexible beam provided with surface bonded piezo-patches while the vibrating beam system is submerged in a fluid. Two main effects are considered: 1) axial stretching of the vibrating beam that leads
... Show MoreAbstractin adult typical atrioventricular nodal reentrant tachycardia (AVNRT) consider most common paroxysmalsupraventricular tachycardia. Dual pathway idea still accepted and used widely and commonly. According tothe guide line, ablations of slow pathway still the first treatment with good success rate.Identify the electrophysiological difference of atrioventricular nodal pathways pre and post ablation.Electrophysiological study was done to 54 patients with only typical type AVNRTs; they were 40 (74%)females and 14 (26%) males. Divided into two groups G1 with 38 patients (70.4%) having one pathway andG2 with 16 patients (29.6%) with multiple pathway. After induction we study the clinical andelectrophysiological feature of tachycardia and s
... Show MoreThe research aims to identify the effect of the training program that is based on integrating futuristic thinking skills with classroom interaction patterns on mathematics teachers in order to provide their students with creative solution skills. The research sample consisted of 31teachers (15 teachers for the experimental group and 16 for the control groups). The researcher developed a measure for the academic self-efficacy consisting of (39) items. Its validity, reliability, coefficient of difficulty and discriminatory power were estimated. To analyze the findings, the researcher adopted the Mann-Whitney (U) test and the effect size, and the findings were as follows: There is a statistically significant difference at the significance leve
... Show MoreThis study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO
... Show MoreThis study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis