Preferred Language
Articles
/
QBfkN48BVTCNdQwCWWPS
Performance of BCH and RS Codes in MIMO System Using MPFEC Diversity Technique
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Thu Sep 01 2022
Journal Name
Iop Conference Series: Earth And Environmental Science
Non-Diatomic Diversity and Community Structure in Hoor-Al- Azime Marshes, Iran
...Show More Authors
Abstract<p>This study was conducted to delineate diversity and species composition of non-diatoms planktonic algae in Hoor- Al- Azime marshes, Iran. The samples were collected from four sites at monthly basis from April 2011 to March 2012. A total 88 taxa were identified, out of which (40 taxa, 45.45%) belonging to Cyanophyta followed by Chlorophyta (29 taxa, 32.96%), Euglenophyta (18 taxa, 20.45%) and (1 taxa, 1.14%) of Dinophyta recorded. Comparing species richness (65 taxa, 34.76%) at Shat- Ali (St4) was the highest and the lowest (34 taxa, 18.18%) was observed at Rafi (St2). Species occurrence was associated with temperature where in summer (66 taxa) and (25 taxa) encountered winter. The phy</p> ... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Mon Apr 03 2023
Journal Name
Karbala International Journal Of Modern Science
Performance Estimation and System Modeling for Refractive Index Structure Constant Cn2
...Show More Authors

View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Monitoring of Defects Concentration in Deformed Aluminum Using Doppler Broadening Technique
...Show More Authors

Doppler broadening of the 511 keV positron annihilation ??? ? was used to estimate the concentration of defects ?? different deformation levels of pure alnminum samples. These samples were compressed at room temperature to 15, 22, 28, 38,40, and 75 % thickness reduction. The two-state ^sitron-trapping model has been employed. 'I he s and w lineshape parameters were measured using high-resolution gamma spectrometer with high pure germanium detector of 2.1 keV resolution at 1.33 MeV of 60Co. The change of defects concentration (Co) with the deformation level (e) is found to obey an empirical formula of the form Cd - A £ B where A and ? are positive constants that depend mainly on the deformation procedure and the temperature at which the def

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Mon Dec 03 2018
Journal Name
Journal Of Engineering
Performance of Different Concatenated Coding Schemes for CDMA System
...Show More Authors

In this paper different channel coding and interleaving schemes in DS/CDMA system over multipath fading channel were used. Two types of serially concatenated coding were presented. The first one composed of Reed-Solomon as outer code, convolutional code as inner code and the interleaver between the outer and inner codes and the second consist of convolutional code as outer code, interleaved in the middle and differential code as an inner code. Bit error rate performance of different schemes in multipath fading channel was analyzed and compared. Rack receiver was used in DS/CDMA receiver to combine multipath components in order to enhance the signal to noise ratio at the receiver.

 

View Publication Preview PDF
Crossref
Publication Date
Mon Jan 02 2012
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Image encryption technique using Lagrange interpolation
...Show More Authors

Publication Date
Thu Apr 29 2021
Journal Name
Egyptian Journal Of Chemistry
Fabrication and Study of ZnO thin Films using Thermal Evaporation Technique
...Show More Authors

Pure SnSe thin film and doped with S at different percentage (0,3,5,7)% were deposited from alloy by thermal evaporation technique on glass substrate at room temperature with 400±20nm thickness .The influences of S dopant ratio on characterization of SnSe thin film Nano crystalline was investigated by using Atomic force microscopy(AFM), X-ray diffraction (XRD), energy dispersive spectroscopy (EDS), Hall Effect measurement, UV-Vis absorption spectroscopy to study morphological, structural, electrical and optical properties respectively .The XRD showed that all the films have polycrystalline in nature with orthorhombic structure, with preferred orientation along (111)plane .These films was manufactured of very fine crystalline size in the ra

... Show More
View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Sat Dec 02 2023
Journal Name
Journal Of Engineering
Simulation and Experimental Investigation of Performance and Flow Behavior for Steam Ejector Refrigeration System
...Show More Authors

The ejector refrigeration system is a desirable choice to reduce energy consumption. A Computational Fluid Dynamics CFD simulation using the ANSYS package was performed to investigate the flow inside the ejector and determine the performance of a small-scale steam ejector. The experimental results showed that at the nozzle throat diameter of 2.6 mm and the evaporator temperature of 10oC, increasing boiler temperature from 110oC to 140oC decreases the entrainment ratio by 66.25%. At the boiler temperature of 120oC, increasing the evaporator temperature from 7.5 to 15 oC increases the entrainment ratio by 65.57%. While at the boiler temperature of 120oC and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Baghdad Science Journal
Bacterial Diversity in Different Positions in the Iraqi Marine Area
...Show More Authors

Microorganisms establish both structural and functional construction in the marine environment, despite scientific advances, the identification of marine bacterial species is still considered as a common challenge in microbiology. Nevertheless, the present study aims to make an effort, although it seems modest, but it could establish a basis for studying the bacterial diversity in the Iraqi marine area, because of what this aspect entails of the poverty of studies related to this aspect in the studied area. The current results show the marine studied area are classified within worming area, where the average temperature ranged from 23.17 to 26.17 ºC. The recorded number of bacteria was increased with temperature increasing (0.210, 0.250

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi Journal Of Physics
Transfocation Technique to Overcome Atmospheric Scintillation Effect on a Laser Detection and Tracking System (LDTS)
...Show More Authors

Atmospheric transmission is disturbed by scintillation, where scintillation caused more beam divergence. In this work target image spot radius was calculated in presence of atmospheric scintillation. The calculation depend on few relevant equation based on atmospheric parameter (for Middle East), tracking range, expansion ratio of applied beam expander's, receiving unit lens F-number, and the laser wavelength besides photodetector parameter. At maximum target range Rmax =20 km, target image radius is at its maximum Rs=0.4 mm. As the range decreases spot radius decreases too, until the range reaches limit (4 km) at which target image spot radius at its minimum value (0.22 mm). Then as the range decreases, spot radius increases due to geom

... Show More
View Publication Preview PDF