Abstract: Recombinant human bone morphogenetic protein-2 (rhBMP-2) and platelet-rich fibrin (PRF) bioactive materials have been used to enhance healing and improve dental implant stability. This study aimed to compare the effect of rhBMP-2 and PRF bioactive materials on dental implant stability at different intervals and to evaluate the correlation of implant length and diameter with implant stability. Two bioactive materials were compared to evaluate their effect on dental implant stability. A total of 32 patients (102 dental implants) were divided into 3 groups: 24 dental implants with bone morphogenetic protein (BMP), 27 dental implants with PRF, and 51 dental implants without BMP or PRF (control group). Data were statistically analyzed to determine the bioactive material with the best effect on implant stability. Implant stability did not significantly differ between the groups immediately after implant insertion (first reading; P>0.05). The implant stability of the rhBMP-2 group was significantly better than those of the PRF and control groups 6 weeks after implant insertion (second reading; P¼0.001). After 12 weeks, the effect of rhBMP-2 on implant stability was highly significant and better than that of the other groups (third reading; P<0.001). Dental implants coated with BMP have a better effect on stability than those with PRF alone and those without PRF or BMP.
Background: A diverse group of bacteria live in biofilms in the oral cavity. On dental surfaces biofilms form plaque that is potentially involved in caries and periodontal diseases. Periodic studying of plaque microflora and their antimicrobial sensitivity patterns strongly affects the clinical practice in plaque-induced oral diseases. Materials and methods: Dental plaque samples were collected from 22 patients having ages ranged between 33 and 49 years with gingivitis that met the study criteria. Plaque, gingival and gingival bleeding indices (PI, GI, GBI) were measured for each patient. Laboratory procedures included microbiological examination of plaque samples followed by antibiotic sensitivity testing using disc diffusion method were
... Show MoreObjectives. This study aimed at finding out whether anterior teeth angulation and inclination have a relationship with the maxillary teeth and dental arch dimensions. Methods. Fifty study models with normal occlusion were selected from the archive of the Department of Orthodontics at Baghdad Dental Faculty. Maxillary dental arch width and length at different points were determined in addition to measuring anterior teeth angulation, inclination, crown thickness, overjet, overbite, and Bolton’s ratios. The unpaired t-test and Pearson’s correlation coefficient test were used for data analysis. Results. No statistical gender differences were reported in all measurements except the dental arch widths and length where males had signif
... Show MoreBackground : In order for a tooth to erupt, two obvious requirements are needed. First, there has to be alveolar bone resorption of the bone overlying the crown of the tooth such that an eruption pathway is formed. Second, resorption of bony crypt and apposition of new one, third, there has to be a biological process that will result in the tooth moving through this eruption pathway.The amniotic sac contains a considerable quantity of stem cells. These amniotic stem cells are multipotent and able to differentiate into various tissues, which may be useful for human application. Receptor activator of nuclear factor kappa B ligand (RANKL) is concentrated on bone biology, more specifically bone metabolism. RANKL plays a vital role in osteoclast
... Show MoreABSTRACT Background: Piezosurgery device is a system developed recently to overcome the limitation of the traditional surgical technique in implant site preparation, which use the principle of ultrasonic microvibrations to create precise & selective cut in bone in harmony with the surrounding tissues. The aim of this study was to evaluate the outcomes of implants inserted by ultrasonic implant site preparation protocol (UISP) using piezosurgery device, regarding the survival rate, stability and other related factors, at 16 weeks postoperative follow up period. Materials and Methods: A total of (24) patients, (6) males and (18) females, aged between (19-51) years old, contributed in this study receiving a total of (42) implants, all of these
... Show MoreIn this report Silver doped Tin Sulfide (SnS) thin films with ratio of (0.03) were prepared using thermal evaporation with a vacuum of 4*10-6 mbar on glass with (400) nm thickness and the sample annealing with ( 573K ). The optical constants for the wavelengths in the range (300-900) nm and Hall effect for (SnS and SnS:3% Ag) films are investigated and calculated before and after annealing at 573 K. Transition metal doped SnS thin films the regular absorption 70% in the visible region, the doping level intensification the optical band gap values from 1.5- 2 eV. Silver doped tin sulfide (SnS) its direct optical band gap. Hall Effect results of (SnS and SnS:3% Ag) films show all films were (p-type) electrical conductivity with resistivity of
... Show More Fusobacterium are compulsory anaerobic gram-negative bacteria, long thin with pointed ends, it causes several illnesses to humans like pocket lesion gingivitis and periodontal disease; therefore our study is constructed on molecular identification and detection of the fadA gene which is responsible for bacterial biofilm formation. In this study, 10.2% Fusobacterium spp. were isolated from pocket lesion gingivitis. The isolates underwent identification depending on several tests under anaerobic conditions and biochemical reactions. All isolates were sensitive to Imipenem (IPM10) 42.7mm/disk, Ciprofloxacin (CIP10) 27.2mm/disk and Erythromycin (E15) 25mm/disk, respectively. 100% of
Abstract
Hexapod robot is a flexible mechanical robot with six legs. It has the ability to walk over terrain. The hexapod robot look likes the insect so it has the same gaits. These gaits are tripod, wave and ripple gaits. Hexapod robot needs to stay statically stable at all the times during each gait in order not to fall with three or more legs continuously contacts with the ground. The safety static stability walking is called (the stability margin). In this paper, the forward and inverse kinematics are derived for each hexapod’s leg in order to simulate the hexapod robot model walking using MATLAB R2010a for all gaits and the geometry in order to derive the equations of the sub-constraint workspaces for each
... Show MoreThe article emphasizes that 3D stochastic positive linear system with delays is asymptotically stable and depends on the sum of the system matrices and at the same time independent on the values and numbers of the delays. Moreover, the asymptotic stability test of this system with delays can be abridged to the check of its corresponding 2D stochastic positive linear systems without delays. Many theorems were applied to prove that asymptotic stability for 3D stochastic positive linear systems with delays are equivalent to 2D stochastic positive linear systems without delays. The efficiency of the given methods is illustrated on some numerical examples. HIGHLIGHTS Various theorems were applied to prove the asymptoti
... Show MoreBackground: Coated aesthetic archwires are currently the existing solutions for the esthetic problem, but the color of these archwires tends to change overtime. This study was aimed to evaluate the color stability of different types of esthetic archwires from four different companies at different time periods after immersion of two different staining drinks which are tea and Pepsi cola. Materials and methods: 48 specimens were prepared, each specimen contains 10 aesthetic archwires; and were divided according to type of solution into two groups: A (tea) &B (Pepsi cola); each group contained 24 specimens (12 specimens were immersed in the staining solution as 4 specimens for each time intervals and 12 specimens were immersed in distilled wa
... Show More