Preferred Language
Articles
/
QBYiYocBVTCNdQwC6knw
In Vitro Comparative Assessment of Composite Nanoleakage Using Various Dentine Surface Treatments
...Show More Authors

Background: The treatment of dental tissues proceeding to adhesive procedures is a crucial step in the bonding protocol and decides the clinical success ofrestorations. This study was conducted in vitro, with the aim of evaluating thenanoleakage on the interface between the adhesive system and the dentine treated by five surface modalities using scanning electron microscopy and energydispersiveX-ray spectrometry. Materials and methods: Twenty five extracted premolars teeth were selected in the study. Standardized class V cavities were prepared on the buccal and lingual surfaces then the teeth divided into five main groups of (5 teeth in each group n=10) according to the type of dentine surface treatment that was used: Group (A): dentine was conditioning with Er, Cr: YSGG laser. Group (B): dentine was conditioning with (Er, Cr: YSGG laser + acid). Group (C): dentine was conditioning with (acid + Er, Cr: YSGG laser). Group (D): dentine was conditioning with acid etch. Group (E): dentine was conditioning with acid + 10% sodium hypochlorite. For All the teeth SBMP adhesive were used and restored with Z250 composite restoration then all specimens were subjected to thermocycling 500 cycles, at 5° to 55 °C. The teeth were soaked in silver nitrate suspension. Then the teeth sectioned bucco-lingually across the centre of the restorations. The specimens were characterized using scanning electron microscopy and the amount of nanoleakage was measured by EDX spectro-analysis to identify the existence of metallic silver particles. Results: Data were analysed statistically by one way ANOVA test and (LSD) Tests. The results showed that there were statistically highly significant differences among all groups of the present study.The resultshowed that the acid and laser (group III) exhibited the lowest mean value of nanoleakage at around (6.14 %), whereas the highest mean value of nanoleakage (12.83 %) was determined by the only acid (group IV). Conclusions: Treating the acid etched dentine with Er: Cr: YSGG laser showed promising results as it exhibits lowest amount of nanoleakage of the adhesive bonding system.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of the Biological Activities of Calendula officials Extracts
...Show More Authors

Objective: To assess two kinds of extraction (aqueous and methanolic) for Calendula officials using flowers, leaves
and stems and studying their antibacterial activity against five different bacteria.
Methodology: Calendula officials were selected to carry out this study. Flowers, leaves and stems were collected from
local markets in Baghdad then dried in shade for 7 days and grinded to fine powder. Aqueous hot extracts for 2hr. at
(100c˚) and alcoholic extracts for 48 hrs at (80c˚) were performed using flowers, leaves and stems then studied
antibacterial effect against five different bacterial genuses by using well diffusion technique.
Results: This study showed that hot aqueous extracts for 2hr. to all parts of Cale

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Physics
Effect of industrial powder on mechanical properties of glass fiber reinforced epoxy composite
...Show More Authors

In the present study, composites were prepared by Hand lay-up molding and investigated. The composites constituents were epoxy resin as the matrix, 6% volume fractions of Glass Fibers (G.F) as reinforcement and 3%, 6% of industrial powder (Calcium Carbonate CaCO3, Potassium Carbonate K2CO3 and Sodium Carbonate Na2CO3) as filler. Density, water absorption, hardness test, flexural strength, shear stress measurements and tests were conducted to reveal their values for each type of composite material. The results showed that the non – reinforced epoxy have lower properties than composites material. Measured density results had show an incremental increase with volume fraction increase

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Jul 31 2025
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Temperature and Frequency on the Dielectric Properties of PVC/MnCl2 Composite
...Show More Authors

View Publication
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Study the effect of acid immersion on the hardness of (Epoxy – Granite) composite
...Show More Authors

This work has been done with using of epoxy resin mixed with Granite powder were weighted by percent volume (5,10,15, and 20)%and then mixed with epoxy polymer to compose polymer composite. Hand lay-up technique is used in fabrication of the composite samples. Hardness test was carried out for the proper samples in both normal condition and after immersion in HCL (1 M and 2 M) solutions for periods ranging up to 10 weeks. After comparing the results between the polymer and their composite, the hardness increased with increasing Granite weight percent, it was found that Hardness were greater for the composites before immersion compared with their values after immersion.

View Publication Preview PDF
Crossref
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Engineering
Non-Linear Analysis of Laminated Composite Plates under General Out-Of-Plane Loading
...Show More Authors

The theoretical analysis depends on the Classical Laminated Plate Theory (CLPT) that is based on the Von-K ráman Theory and Kirchhov Hypothesis in the deflection analysis during elastic limit as well as the Hooke's laws of calculation the stresses. New function for boundary condition is used to solve the forth degree of differential equations which depends on variety sources of advanced engineering mathematics. The behavior of composite laminated plates, symmetric and anti-symmetric of cross-ply angle, under out-of-plane loads (uniform distributed loads) with two different boundary conditions are investigated to obtain the central deflection for mid-plane by using the Ritz method. The computer programs is built using Ma

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of dispensing method and curing modes on the microleakage of composite resins
...Show More Authors

Background: Vibration decreases the viscosity of composite, making it flow and readily fit the walls of the cavity. This study is initiated to see how this improved adaptation of the composite resin to the cavity walls will affect microleakage using different curing modes

Materials and methods: Standard Class V cavities were prepared on the buccal surface of sixty extracted premolars. Teeth were randomly assigned into two groups (n=30) according to the composite condensation (vibration and conventional) technique, then subdivided into three subgroups (n=10) according to light curing modes (LED-Ramp, LED-Fast and Halogen Continuous modes). Cavities were etched and bonded with Single Bond Universal

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Fri Jun 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Analysis of composite variance of experiments carried out according to design Latin box
...Show More Authors

We know that the experiments which conducted by latin square in one location or in one period (season), but there are many cases that need to conduct the same experiments in many locations or in many periods (seasons) to study the interaction  between the treatments and locations or between the treatments and periods (seasons) .In this research we present  an idea for  conduct  the experiment in several locations and in many period (seasons) by using LSD , it represent  acontribution in the area of design and analysis of experiments ,we had written. we had written (theoretically)  the general plans, the mathematical models for these experiments, and finding the derivations of EMS for each component (

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Composite Structures
Computational homogenization of the elastic and thermal properties of superconducting composite MgB2 wire
...Show More Authors

View Publication
Scopus (42)
Crossref (40)
Scopus Clarivate Crossref
Publication Date
Thu Jul 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Surface properties of heat treated with different durations of titanium alloy dental implants
...Show More Authors

Background: The surface properties of the titanium alloy plays a significant role in the bond of the dental implant with living bone and modification of the implant surface could enhance osseointegration. This study was aimed to investigate the effect of different durations of heat treatment on the surface properties of titanium alloy for dental implants. Materials and methods: Twenty disks of (Ti-6Al-4V) alloy were prepared. The sample was divided into four test groups to study the effect of different duration of heat treatment to the surface topography; surface chemistry, titanium oxide layer thickness, blood contact angle, & blood drop diameter of titanium alloy samples were investigated to evaluate the effect of different durations of

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 05 2022
Journal Name
Baghdad Science Journal
Influence of Optical Fiber Diameters on the Performance of Surface Plasmon Resonance Sensor
...Show More Authors

In this research, a sensor for chemical solutions was designed and formed using optical fiber-based on a surface Plasmon resonance technology. A single-mode optical fiber with three different diameters (25, 45 and 65) µm was used, respectively.  The second layer of the low refractive fiber was replaced by gold, which was electrically deposited at 40 µm thickness. For each of the three types of optical fiber, different saline concentrations (different index of refraction) were used to evaluate the performance of the refractive index sensor (chemical sensor) by measuring its sensitivity and resolutions. The highest values we could get for these two parameters were 240mm/RIU, and 6*10-5 RIU respectively, when the diameter of a

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (4)
Scopus Crossref