Preferred Language
Articles
/
PuaNZZwBmraWrQ4dO0lS
Novel cytotoxicity of nano-coated orthodontic micro-implants: An <i>in vitro</i> study
...Show More Authors
Objectives:

Many attempts have been made to modify the surface of orthodontic micro-implants and prevent the development of microbes by coating them with antimicrobial nanoparticles (NPs). The purpose of the present study was to evaluate the cytotoxicity of different NPs, namely, TiO2 and zinc oxide (ZnO) NPs, that are used to coat titanium orthodontic micro-implants.

Material and Methods:

Thirty orthodontic micro-implants were included in this study. Those were divided into three groups: control group without coating, TiO2-coated orthodontic micro-implants, and TiO2- and ZnO-coated orthodontic micro-implants. Scanning electron microscope, energy-dispersive spectroscopy (EDS), and cytotoxicity tests were applied for all groups.

Results:

The results of scanning electron microscopy and EDS showed effective deposition of the titanium oxide layer onto the micro-implants. The ZnO layer applied on the micro-implants exhibited superior physicochemical characteristics in comparison to the uncoated samples with no significant cytotoxicity.

Conclusion:

Both NPs showed biocompatibility with the oral tissues.

Scopus Crossref
View Publication
Publication Date
Sun Sep 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of surface microhardness of enamel surface treated with Nano- HAP serum before and after bleaching
...Show More Authors

Background: Although bleaching is typically considered a safe procedure, various investigations have found minor negative effects and changes in mineral composition. The aim was to Evaluate and compare the efficacy of using Nanohydroxyapatite serum on surface microhardness of enamel surface before and after bleaching with chemically cured Boost bleaching. Material and methods: ten sound human permanent upper and lower premolar teeth were used and their roots were removed 2 mm apically to the cementoenamel junction, the crowns were sectioned mesiodistally into two halves buccal and lingual/palatal, the buccal surface was further subdivided into two halves. The samples were embeded in an acrylic resin, resulting in 30 specimens divide

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jan 07 2021
Journal Name
Indian Journal Of Forensic Medicine &amp; Toxicology
Effect of Dentifrices with Different Abrasives on the Surface Roughness of a Nano Composite Resins materials
...Show More Authors

Background: to evaluate the effect of different dentifrices on the surface roughness of two composite resins (nanofilled-based and nanoceramic – based composite resins). Materials and methods: Forty specimens (diameter 12 mm and height of 2mm) prepared from different composite resin materials: Z350 (nanofilled composite, and Ceram-X (nanoceramic) .they were subjected to brushing simulation equivalent to the period of 1 year. The groups assessed were a control group brushed with distilled water (G1), Opalescence whitening toothpasteR (G2), Colgate sensitive pro-relief (G3) and Biomed Charcoal Toothpaste (G4). The initial and final roughness of each group was tested by surface roughness tester. The results were statistically analyzed using

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of Taibah University Medical Sciences
Effect of nano-titanium oxide addition on some mechanical properties of silicone elastomers for maxillofacial prostheses
...Show More Authors

Objective This study evaluated the effects of adding titanium oxide (TiO2) nanofillers on the tear strength, tensile strength, elongation percentage, and hardness of room-temperature-vulcanized (RTV) VST50F and high-temperature-vulcanized (HTV) Cosmesil M511 maxillofacial silicone elastomers. Methods Two types of maxillofacial elastomers, VST50F RTV and Cosmesil M511 HTV, were used. Nano-TiO2 powder was applied as a nanofiller. A total of 120 specimens were fabricated, 60 each of VST50F and Cosmesil M511. The specimens of each type of elastomer were divided into three equal groups on which tests were conducted for tear strength, tensile strength, and hardness i.e., 20 specimens were used for each test. Each group of 20 specimens was further

... Show More
View Publication
Scopus (34)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Thu Jan 04 2024
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The impact of performance based costing technology in measuring the cost of consulting services : (an applied study in the Office of Scientific and Consulting Services - University of Technology
...Show More Authors

 

             This research aims to apply the Performance Focused Activity Based Costing System in the offices of scientific and advisory services at the University of Technology for the purpose of measuring the cost of services provided by these offices in order to reduce costs. To test the hypothesis of the research, the research was applied in the consulting offices of the University of Technology through the financial statements for the year ending 12/31/2017 of the Scientific and Consulting Services Office of the University of Technology, because the data of these years were issued and audited by the Federal Office of Financial Supervision.

A number of

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2017
Journal Name
The Journal Of Immunology
Definition of the Nature and Hapten Threshold of the β-Lactam Antigen Required for T Cell Activation In Vitro and in Patients
...Show More Authors
Abstract<p>Covalent modification of protein by drugs may disrupt self-tolerance, leading to lymphocyte activation. Until now, determination of the threshold required for this process has not been possible. Therefore, we performed quantitative mass spectrometric analyses to define the epitopes formed in tolerant and hypersensitive patients taking the β-lactam antibiotic piperacillin and the threshold required for T cell activation. A hydrolyzed piperacillin hapten was detected on four lysine residues of human serum albumin (HSA) isolated from tolerant patients. The level of modified Lys541 ranged from 2.6 to 4.8%. Analysis of plasma from hypersensitive patients revealed the same pattern and leve</p> ... Show More
View Publication
Scopus (64)
Crossref (64)
Scopus Clarivate Crossref
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study on the Effect of Shape and Location of Vortex Generators Ahead of a Heat Exchanger
...Show More Authors

An experimental study is carried out on the effect of vortex generators (Circular and square) on the flow and heat transfer at variable locations at (X = 0.5, 1.5, 2.5 cm) ahead of a heat exchanger with Reynolds number ranging from 62000< Re < 125000 and heat flux from 3000 ≤ q ≤ 8000 W/m2 .

In the experimental investigation, an apparatus is set up to measure the velocity and temperatures around the heat exchanger.                     

The results show that there is an effect for using vortex generators on heat transfer. Also, heat transfer depends on the shape and location. The circular is found t

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
An empirical Evaluation of the effect of service encounter on customer voluntary behavior: Exploration study of (TBI) customers
...Show More Authors

Purpose: To determine the impact of service encounter in stimulating voluntary customer behaviors.

  • Approach / methodology: It was selected a sample of customers Bank Iraqi Trade (TBI) was (105) individual, using a questionnaire designed in the light of previous studies, was drafted scale and tested in the light of a group of statistical methods developed (reliability coefficient, reliability coefficient composite, convergence). Then test hypotheses through structural equation modeling.
  • Results: The behaviors and characteristics of the service provider in effect urged bank customers to perform voluntary extra, as the service environment service encounter

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
REVIEW THE ASSESSMENT OF EFFECTS OF LOST TIME INJURIES IN AN INDUSTRIAL SYSTEM BY USING AN EXPLANATORY PROGRAM
...Show More Authors

Health and safety problem can be described by statistics it can only be understood by knowing and feeling the pain, suffering, and depression. Health and safety has a legal responsibility to protect it for everyone who can affect in the workplace. This includes manufacturers, suppliers, designers and controllers of work places and employees. Work injury is one of the major problems in manufacturing and production systems industries; it is reduced production efficiency and affects the cost. To gain flexibility from a traditional manufacturing system and production efficiency, this paper is about the application of estimating technology to preview and synthesis of Lost Time of Work Injuries in industry systems aims to provide a safe workin

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Nov 26 2010
Journal Name
Wireless Personal Communications
Security Problems in an RFID System
...Show More Authors

View Publication
Scopus (24)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Sat Apr 04 2020
Journal Name
Biochemical And Cellular Archives
SYNTHESIS, CHARACTERIZATION AND EVALUATION OF ANTIOXIDANT IN-VIVO AND IN-VITRO AND ANTIBACTERIAL FOR N-(3,4- DIHYDROXYBENZYLIDENE) ACETOHYDRAZONE-2-(BENZYLTHIO) BENZIMIDAZOLE
...Show More Authors