A simple and highly sensitive cloud point extraction process was suggested for preconcentration of micrograms amount of isoxsuprine hydrochloride (ISX) in pure and pharmaceutical samples. After diazotization coupling of ISX with diazotized sulfadimidine in alkaline medium, the azo-dye product quantitatively extracted into the Triton X-114 rich phase, dissolved in ethanol and determined spectrophotometrically at 490 nm. The suggested reaction was studied with and without extraction and simple comparison between the batch and CPE methods was achieved. Analytical variables including concentrations of reagent, Triton X-114 and base, incubated temperature, and time were carefully studied. Under the selected optimum conditions, the linearity ranges of calibration curves were 1-9 and 0.5-8 µg/mL with detection limits of 0.26 and 0.09 µg/mL of ISX for batch and CPE methods respectively. A relative standard deviation (RSD %) best than 1.98 and 2.67 % with the percentage recoveries range 100.14 and 99.63 % were obtained for both methods respectively. The proposed methods were successfully used in routine analysis of ISX in pharmaceutical forms with high accuracy and reproducibility.
The aim of this study is to investigate the kinetics of copper removal from aqueous solutions using an electromembrane extraction (EME) system. To achieve this, a unique electrochemical cell design was adopted comprising two glass chambers, a supported liquid membrane (SLM), a graphite anode, and a stainless-steel cathode. The SLM consisted of a polypropylene flat membrane infused with 1-octanol as a solvent and bis(2-ethylhexyl) phosphate (DEHP) as a carrier. The impact of various factors on the kinetics constant rate was outlined, including the applied voltage, initial pH of the donor phase solution, and initial copper concentration. The results demonstrated a significant influence of the applied voltage on enhancing the rate of c
... Show MoreGeodesy is concerned with the relative positioning of points and the gravity field of the earth. For this task, a well-defined coordinate system is needed on which measurements are normally tied to a set of reference points called a geodetic datum (geoid or ellipsoid). The Global Positioning System GPS gives accurately the three-dimensional position of a point (latitude, longitude, and ellipsoidal height) and can measure under all weather conditions. The coordinates of the GPS reference to the World Geodetic System1984 (WGS 84), a global ellipsoid having its origin as the mass center of the earth, and height, referenced to the surface of the ellipsoid . In this research , using RTK-DGPS technique Data collection for study local and level
... Show MoreThere are many problems facing the economic entities as a result of its mass production &variation of its products , the matter which had increased the need & importance of cost accounting which is regarded a main tool for the managerial control.
The actual costing system is unable to meet the contemporary management needs ,so the Standard costing system appear to provide the management with required information to perform its functions by the best use& way.
This research aims to determine the standard cost for the direct material for oil extraction activity by applying it in the north oil company.
A simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was
... Show MoreThe distribution of the intensity of the comet Ison C/2013 is studied by taking its histogram. This distribution reveals four distinct regions that related to the background, tail, coma and nucleus. One dimensional temperature distribution fitting is achieved by using two mathematical equations that related to the coordinate of the center of the comet. The quiver plot of the gradient of the comet shows very clearly that arrows headed towards the maximum intensity of the comet.
Fifty isolates of Bacillus sp. were subjected to the first and second screening to detect the ability to produce laccase enzyme and select the highest ones production of laccase on Petri plates containing nutrient agar supplemented with Cu2+.
Syringaldazine was used as an indicator and substrate for the determination of laccase activity. Three isolates, which consumed less time to developed pink color were tested for the production of laccase quantitatively. The effective isolate B16 with significant amounts of laccase 1.84 unit /ml was selected for laccase study.
The optimization studies revealed that the maximum laccase production was achieved when the production medium was at the following conditions: 5 days of incubation, tempe
In this research, optical absorption data (the imaginary part of the dielectric function Ɛ2 as a function of photon energy E) were re-analyzed for three samples of a-Si:H thin films using derivative methods trying to investigate the ambiguity that accompany the interpretation of the optical data of these film in order to obtainm the optical energy gap (Eg) and the factor (r) which in concerned with the density of state distribution near the mobility edge directly without the need for a pre- assumption for the factor r usually followed in traditional methods such as the Tauc plot. The derivative method was used for two choices for the factor q (which in connected with the dependence of the dipole matrix element on the photon energy ) for
... Show MoreThis paper aims to propose a hybrid approach of two powerful methods, namely the differential transform and finite difference methods, to obtain the solution of the coupled Whitham-Broer-Kaup-Like equations which arises in shallow-water wave theory. The capability of the method to such problems is verified by taking different parameters and initial conditions. The numerical simulations are depicted in 2D and 3D graphs. It is shown that the used approach returns accurate solutions for this type of problems in comparison with the analytic ones.