Preferred Language
Articles
/
PYbxY4YBIXToZYALPIly
Output Feedback Adaptive Sliding Mode Control Design for a Plate Heat Exchanger
...Show More Authors

The heat exchanger is a device used to transfer heat energy between two fluids, hot and cold. In this work, an output feedback adaptive sliding mode controller is designed to control the temperature of the outlet cold water for plate heat exchanger. The measurement of the outlet cold temperature is the only information required. Hence, a sliding mode differentiator was designed to estimate the time derivative of outlet hot water temperature, which it is needed for constructing a sliding variable. The discontinuous gain value of the sliding mode controller is adapted according to a certain adaptation law. Two constraints which imposed on the volumetric flow rate of outlet cold (control input) were considered within the rules of the proposed adaptation law in this work. These are the control input is a positive quantity, and it limited by a maximum value. The maximum allowable desired outlet cold water has been estimated as function of heat exchanger parameters and maximum control input. The simulation results demonstrate the performance of the proposed adaptive sliding mode control where the outlet cold water was forced to follow desired temperature equal to 45𝑜 . Additionally, the robustness of the proposed controller was tested for the case where the cold water inlet temperature is not constant, and also for the case of heat exchanger parameters uncertainty. The results were revealed the robustness of the proposed controller.

Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 17 2022
Journal Name
Iraqi Journal Of Laser
PDF Design Optical BPF Using Double Clad Fiber MZI for Free Space Optical Communication: Mohanad G. Khamees , Tahreer S. Mansour*
...Show More Authors

Abstract: A novel design of Mach Zehnder Interferometer (MZI) in terms of using special type of optical fiber that has double clad with graded distribution of the refractive index that can be easily implemented practically was suggested and simulated in this work. The suggested design is compact, rapid, and is simple to be modified and tested. The simulated design contains a MZI of 1546.74 nm of central wavelength that is constructed using special type of double clad optical fiber that has two different numerical apertures. The first aperture will supply single mode propagation via its core, while the second numerical aperture supports a zigzag wave propagation (multimode) in the first clad region. The interferometer’s

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 20 2019
Journal Name
Al-khwarizmi Engineering Journal
Design and Simulation of Closed Loop Proportional Integral (PI) Controlled Boost Converter and 3-phase Inverter for Photovoltaic (PV) Applications
...Show More Authors

This research deals with the design and simulation of a solar power system consisting of a KC200GT solar panel, a closed loop boost converter and a three phase inverter by using Matlab / Simulink. The mathematical equations of the solar panel design are presented. The electrical characteristics of the panel are tested at the values ​​of 1000  for light radiation and 25 °C for temperature environment. The Proportional Integral (PI) controller is connected   as feedback with the Boost converter to obtain a stable output voltage by reducing the oscillations in the voltage to charge a battery connected to the output of the converter. Two methods (Particle Swarm Optimization (PSO) and Zeigler- Nichols) are used for tuning

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Nov 27 2022
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Extent of auditors' commitment to the quality control system according to the Iraqi Audit guide / 7 : A field study of a sample of auditors of the second district audit office In the The Federal Financial Supervision Board
...Show More Authors

The research aims to achieve a set of objectives, the most important of which is determining the extent to which the auditors of the research sample in the Federal Bureau of Financial Supervision adhere to the requirements of the quality control system according to the Iraqi Audit Manual No. The federal financial / research sample with the quality control system according to the Iraqi audit guide No. 7), and the researcher seeks to test the main research hypothesis and sub-hypotheses, and to achieve this, a questionnaire was designed by (Google Form) and distributed electronically to the elements of the research sample, Through the statistical package program (SPSS), the results of the questionnaire were analysed. In light of the applied

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
PARAMETRIC STUDY OF NATURAL CONVECTIVE AND RADIATIVE HEAT TRANSFER IN INCLINED CYLINDRICAL ANNULI
...Show More Authors

The unsteady state laminar mixed convection and radiation through inclined
cylindrical annulus is investigated numerically. The two heat transfer mechanisms of
convection and radiation are treated independently and simultaneously. The outer
cylinder was kept at a constant temperature while the inner cylinder was heated with
constant heat flux. The study involved numerical solution of the governing equations
which are continuity, momentum and energy equations using finite difference method
(FDM), where the body fitted coordinate system (BFC) was used to generate the grid
mesh for computational plane. A computer program (Fortran 90) was built to calculate
the bulk Nusselt number (Nub) after reaching steady state con

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Finding timewise diffusion coefficient from nonlocal integral condition in one-dimensional heat equation
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Dec 23 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Surface properties of heat treated with different durations of titanium alloy dental implants
...Show More Authors

Background: The surface properties of the titanium alloy plays a significant role in the bond of the dental implant with living bone and modification of the implant surface could enhance osseointegration. This study was aimed to investigate the effect of different durations of heat treatment on the surface properties of titanium alloy for dental implants. Materials and methods: Twenty disks of (Ti-6Al-4V) alloy were prepared. The sample was divided into four test groups to study the effect of different duration of heat treatment to the surface topography; surface chemistry, titanium oxide layer thickness, blood contact angle, & blood drop diameter of titanium alloy samples were investigated to evaluate the effect of different durations of

... Show More
View Publication Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
The effect of heat treatment on structure property of (Bentonite - Alumina - Silica) Ceramic
...Show More Authors
Abstract<p>In this work, a ceramic model has obtained from Iraqi bentonite as a base material with limited additions of alumina and silica. The selected material can bear temperatures higher than the bearing temperature of bentonite as it achieved tolerance temperatures (1300°C) based on X-ray diffraction patterns. It was found that the addition of alumina and silica led to the occurrence of basic phases such as mullite, quartz, cordierite and feldspar in percentages that depended on the percentage of addition in the mixture and the firing temperature, which was (1000-1300)°C.</p>
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Al-khwarizmi Engineering Journal
Influence of Aging Heat Treatment on Pitting Corrosion Resistance of Martensitic Stainless Steel
...Show More Authors

In this research is to study the influence of the aging heat treatment on the pitting corrosion resistance of martensitic stainless steel (MSS), where a number of specimens from martensitic stainless steel were subjected to solution treatment at 1100 oC for one hour followed by water quenching then aging in the temperatures range (500-750) oC for different holding times (1,5,10,15&20) hr. Accelerated chemical corrosion test and immersion chemical corrosion test were performed on samples after heat treatment. The results of the research showed that the pitting corrosion resistance is significantly affected by the aging temperature. Where found that the aging samples at a temperature of 500 °C have the highest ra

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Design and Implementation of a Generalized N-Digit Binary-To-Decimal Converter on an FPGA Seven-Segment Display Using Verilog Hdl
...Show More Authors

It is often needed to have circuits that can display the decimal representation of a binary number and specifically in this paper on a 7-segment display. In this paper a circuit that can display the decimal equivalent of an n-bit binary number is designed and it’s behavior is described using Verilog Hardware Descriptive Language (HDL).
This HDL program is then used to configure an FPGA to implement the designed circuit.

View Publication Preview PDF
Crossref
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Influence of Immersion Period on the Corrosion Behavior of Heat Treated Biomedical Alloy Ti -5Al - 2.5Fe
...Show More Authors

Heat treatment by solid solution method in the ?+? phase region was used at 970°C for Ti-5Al-2.5Fe alloy. The specimens cooled under different cooling media [water quenched (WQ), air cooled (AC) and furnace cooled (FC)], and subsequently aged at 550°C for 4 hours. Five specimens from each treatment were immersed in simulated body fluid SBF for a period of time (3 months). The dependence of corrosion rate on compositional variation in the phases resulted from various type of cooling rates are discussed based on immersion tests. The EDXA results show the precipitation of phosphate and calcium compounds on the alloy after 3 months of immersion in blood plasma solution forming a bone-like apatite, which enhanced the alloy biocompatibility ma

... Show More
View Publication Preview PDF
Crossref