Background. Gene polymorphisms affect etanercept’s pharmacokinetics, pharmacodynamics, and side effects. This effect is evidenced by the extensive genetic variation in the drug’s targets. Objectives. This study aims to find the association between different genotypes of the promoter region of the TNF-α gene at -308G/A(rs1800629), -857C/T(rs1799724), -863 C/A(rs1800630), -1031 T/C (rs1799964), -806 C/T (rs4248158) and -376 G/A (rs1800750) and the side effects of ETN that occurred to Iraqi RA patients. Method. The trial included patients with rheumatoid arthritis who had been using ETN for at least six months. The participants were from the Baghdad Teaching Hospital Rheumatology Unit. The PCR was sequenced to determine the polymorphism in the TNF- promoter region at sites -308 G/A (rs1800629), -857 C/T (rs1799724), -863 C/A (rs1800630), -1031 T/C (rs1799964), and -376 G/A (rs4248158) (rs1800750). The link between the genetic variation at these loci and the etanercept’s most frequent adverse effect was then investigated. Results. The only genotype of (-376 G/A) significantly related to an increased risk of upper respiratory tract infection is the GG genotype, according to the results of this study. However, genotypes for the remaining SNPs did not demonstrate a statistically significant association between ETN and an increased risk of upper respiratory tract infections, injection site response, or skin rash in patients. Conclusion. This study revealed that only the GG genotype of (-376 G/A) was significantly associated with an elevated risk of upper respiratory tract infection.
This work describes an experimental setup to evaluate the photodynamictoxicity of 650 nm diode laser and 532 nm Frequency-doubled Q-Switched Nd:YAG laser on the growth of Candida albicans as well as the potential fungicidal effect when combining the laser irradiation with specific photosensitizers namely methylene blue, toluidine blue, acridine orange and safranin O. In this study the findings showed that the number of colony-forming units per millilitre (CFU/ml) of C. albicans decreased with increasing exposure time. In particular in the case of the frequency doubled Nd:YAG laser combined with safranin O, the best lethal effect occurred at 11 minutes exposure time with 2.26 J/cm² energy density (89.18% reduction) in comparison with the
... Show MoreBACKGROUND: Nebulized Salbutamol have great advantages for patients with respiratory problems by depositing drugs directly to the lungs, inspite of reported adverse metabolic effects on different electrolytes and glucose heamostasis of patients.AIM OF STUDY: To evaluate the effect of nebulized salbutamol used in the management of patients with asthma who have normal serum potassium and blood glucose levels. in the emergency department after 30 and 60 minutes of administration and to find out if these results are of clinical importance that should be taken in consideration when treating patients especially those with abnormal glucose hemostasis or electrolyte disturbance. PATIENTS & METHODS: The study is a prospective follow
... Show MoreSince its start spreed "Severe acute respiratory syndrome coronavirus 2" was discovered in Wuhan, China.that is chargeable COVID-19, a pandemic virus, has end up a widespread fitness hassle everywhere in the global Over 2.1 million people have been affected. We analyze serum concentration of CD4 marker and CD8 marker depend in COVID-19 sufferers, and to make clear a relationship between these variables and disorder Progression and severity For those purpose, (158) sufferers with COVID-19 (showed with the aid of using polymerase chain reaction) and (22) seemingly wholesome human beings have been protected withinside the present day examine and taken into consideration as a manipulate group. All examine population (sufferers and manipulate) h
... Show MoreBackground: Many structural or functional abnormalities can impair the production of thyroid hormones and cause hypothyroidism.Objectives: to identify the main etiological causes of hypothyroidism among patients visiting Specialized Center for Diabetes and Endocrinology.Methods: This study was conducted in the Specialized Center for Diabetes and Endocrinology on 217 patients with proved hypothyroidism, from 2006 to 2008. Every patient was tested with thyroid function tests, Ultrasound examination, thyroid autoantibodies, fine needle aspiration, radiology of skull, isotopes scan, also checking adrenal and gonadal function. Results: Out of these 217 patients 120 patients have thyroiditis 33 patients had been undergone thyroidectomy. 39 pat
... Show MoreBackground: This study aims to investigate the effect of fixed orthodontic appliances and/or antihypertensive drugs on the weight of experimental rats. Materials and Methods: Thir-ty-six male Wistar albino rats were subjected to a split-mouth design study, in which an orthodontic appliance was inserted in one side to move the first molar mesially for 2 weeks while the other side acted as a control to tooth movement. The rats were allocated into three groups: group A (n = 12), without any pharmacological treatment; group B (n = 12), subcu-taneous injection of bisoprolol fumarate (5 mg/kg) daily; and group C (n = 12), subcutaneous injection of valsartan (10 mg/kg) daily. A fixed orthodontic appliance with a closing coil spring delivering 5
... Show MoreThe purpose of this study was to investigate the effect of omega-3 poly unsaturated fatty-acids co-administered with the therapeutic dose of lornoxicam on liver of healthy rats. Twenty-eight adults male rats weighing 180-200g were used in this study and the animals were randomly divided into four groups of seven rats each. Group I: negative control/rats intraperitoneally injected with normal saline in a dose 5ml/kg/day; Group II: rats intraperitoneally injected with lornoxicam at dose 0.7 mg/kg/day; Group III: rats orally-administered omega-3 only at a dose 185mg/kg/day; Group IV: rats co-administered omega-3 (185mg/kg/day) orally and in
... Show More