Preferred Language
Articles
/
OubUsp4BmraWrQ4d_WWE
Numerical Study of Convective Heat Transfer in a Rectangular Channel Inserted with Metal Foam of Gradient Pore Density
...Show More Authors

Metal foam has recently been used in many engineering applications, such as solar collectors, heat exchangers, and cooling of electronic devices, which calls for studying different cases of using metal foam in these applications. The current study conducts a numerical analysis of heat transfer and fluid flow characteristics for air in a rectangular channel filled with high-porosity copper foam. The study examined the thermal performance for two cases of gradient pore density, which are arranged as (10-20-40) PPI and (40-20-10) PPI. These cases were compared with two other cases for constant pore density, 10 and 40 PPI, and empty cases. The ANSYS FLUENT 20.0 employed the Darcy-Forchheimer extended Brickman model in the two-dimensional domain with the local thermal non-equilibrium model (LTNE) for the energy equation to obtain the numerical simulation for this study. The working parameters included air with Re from 200 to 2100 and applied heat flux from 450 to 6000 W/m2. The results indicated that employing metal foam with a low pore density led to a decrease in both the Nusselt number and pressure drop. Both gradient cases exhibited Nusselt numbers and friction factors that fell within the range of the constant PPI cases, but one of the gradient cases increased the performance factor by 10%. In general, the PPI configuration of 10-20-40 exhibited a higher heat transfer coefficient in comparison to the 40-20-10 PPI arrangement with the same pressure drop.

Crossref
View Publication
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Numerical Analysis of Fluid Flow and Heat Transfer by Forced Convection in Channel with one-sided Semicircular Sections and Filled with Porous Media
...Show More Authors

This research presents a numerical study to simulate the heat transfer by forced convection as a result of fluid flow inside channel’s with one-sided semicircular sections and fully filled with porous media. The study assumes that the fluid were Laminar , Steady , Incompressible and inlet Temperature was less than Isotherm temperature of a Semicircular sections .Finite difference techniques were used to present the governing equations (Momentum, Energy and Continuity). Elliptical Grid is Generated using Poisson’s equations . The Algebraic equations were solved numerically by using (LSOR (.This research studied the effect of changing the channel shapes on fluid flow and heat transfer  in two cases ,the first: cha

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 15 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Natural Convective Heat Transfer in an Inclined Open Porous Cavity with Non-Uniformly Heated Wall
...Show More Authors

Theoretical and experimental investigations of free convection through a cubic cavity with sinusoidal heat flux at bottom wall, the top wall is exposed to an outside ambient while the other walls are adiabatic saturated in porous medium had been approved in the present work. The range of Rayleigh number was and Darcy number values were . The theoretical part involved a numerical solution while the experimental part included a set of tests carried out to study the free convection heat transfer in a porous media (glass beads) for sinusoidal heat flux boundary condition. The investigation enclosed values of Rayleigh number (5845.6, 8801, 9456, 15034, 19188 and 22148) and angles of inclinations (0, 15, 30, 45 and 60 degree). The numerical an

... Show More
Publication Date
Sat Sep 01 2007
Journal Name
Al-khwarizmi Engineering Journal
Free Convective Heat Transfer with Different Sections Lengths Placed at the Exit of a Vertical Circular Tube subjected to a Constant Heat Flux
...Show More Authors

A free convective heat transfer from the inside surface of a uniformly heated vertical circular tube has been experimentally investigated under a constant wall heat flux boundary condition for laminar air flow in the ranges of RaL from 6.9108 to 5109. The effect of the different sections (restrictions) lengths placed at the exit of the heated tube on the surface temperature distribution, the local and average heat transfer coefficients were examined. The experimental apparatus consists of aluminum circular tube with 900 mm length and 30 mm inside diameter (L/D=30). The exit sections (restrictions) were included circular tubes having the same inside diameter as the heated tube but with different lengths of

... Show More
View Publication Preview PDF
Publication Date
Tue Jul 21 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Numerical Study of the Heat Transfer Behavior in Helical Microcoil Tube
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Journal Of Engineering
Numerical study of natural convection in an annulus between two concentric cylinders provided with metal foam fins
...Show More Authors

Natural convection in an annular space provided with metal foam fins attached to the inner cylinder is studied numerically. The metal foam fins made of copper were inserted in different axial sections with three fins in each section. The temperature of the inner cylinder is kept constant while the annular outer surface is adiabatic. The thickness effect of the inner pipe wall was considered. Naiver Stokes equation with Boussinesq approximation is used for the fluid regime while Brinkman-Forchheimer Darcy model is used for metal foam. In addition, the local thermal non-equilibrium condition in the energy equation of the porous media is presumed. The effect of Rayleigh numb

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Nov 01 2015
Journal Name
Energy Conversion And Management
Laminar convective heat transfer of hexylamine-treated MWCNTs-based turbine oil nanofluid
...Show More Authors

Multi-walled carbon nanotubes (MWCNTs) were functionalized by hexylamine (HA) in a promising, cost-effective, rapid and microwave-assisted approach. In order to decrease defects and remove acid-treatment stage, functionalization of MWCNTs with HA was carried out in the presence of diazonium reaction. Surface functionality groups and morphology of chemically-functionalized MWCNTS were characterized by FTIR, Raman spectroscopy, thermogravimetric analysis (DTG), and transmission electron microscopy (TEM). To reach a promising dispersibility in oil media, MWCNTs were functionalized with HA. While the cylindrical structures of MWCNTs were remained reasonably intact, characterization results consistently confirmed the sidewall-functionalization o

... Show More
Scopus (74)
Crossref (74)
Scopus Clarivate Crossref
Publication Date
Sun Dec 30 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Estimating of Pore Pressure Gradient in Lower Fars Formation
...Show More Authors

In petroleum industry, the early knowledge of “pore pressure gradient” is the basis in well design and the extraction of these information is more direct when the pore pressure gradient is equal to normal gradient; however, this matter will be more complex if it deviate from that limit which is called “abnormal pore pressure”, if this variable does not put in consideration, then many drilling problems will occur might lead to entire hole loss. To estimate the pore pressure gradient there are several methods, in this study; Eaton method’s is selected to extract the underground pressure program using drilling data (normalized rate of penetration) and logs data (sonic and density log). The results shows that an abnormal high press

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Aug 16 2022
Journal Name
Heat Transfer
Experimental study on thermo‐hydraulic performance of metal foam twisted tape in a double pipe heat exchanger
...Show More Authors
Abstract<p>A recent study compared experimentally the hydraulic and thermal activity of twisted tape inserts for two types, metal foam twisted tape (MFTT) and traditional twisted tape (TTT), in a double pipe heat exchanger. The investigation goal of the innovatively designed MFTT is to enhance the heat transfer process, which provides a higher thermal enhancement factor over those of TTT under the same conditions. Heat transfer activity in terms of Nusselt number (<italic>Nu</italic>) and Nusselt number ratio (<italic>Nu</italic>/<italic>Nu</italic><sub>o</sub>) as the heat exchanger equipped with the proposed MFTT and TTT inserts with various tape‐twist ratios (<i></i></p> ... Show More
View Publication
Scopus (12)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Internal Convective Heat Transfer Effect on Iraqi Building Construction Cooling Load
...Show More Authors

This work involves the calculation of the cooling load in Iraqi building constructions taking in account the effect of the convective heat transfer inside the buildings. ASHRAE assumptions are compared with the Fisher and Pedersen model of estimation of internal convective heat transfer coefficient when the high rate of ventilation from ceiling inlet configuration is used. Theoretical calculation of cooling load using the Radiant Time Series Method (RTSM) is implemented on the actual tested spaces. Also the theoretical calculated cooling loads are experimentally compared by measuring the cooling load in these tested spaces. The comparison appears that using the modified Fisher and Pedersen model when large ventilation ra

... Show More
View Publication Preview PDF
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Evaluation of Convective Heat Transfer and Natural Circulation in an Evacuated Tube Solar Collector
...Show More Authors

The evacuated tube solar collector ETC is studied intensively and extensively by experimental and
theoretical works, in order to investigate its performance and enhancement of heat transfer, for Baghdad climate
from April 2011 till the end of March 2012. Experimental work is carried out on a well instrumented collector
consists of 16 evacuated tubes of aspect ratio 38.6 and thermally insulated tank of volume 112L. The relation
between convective heat transfer and natural circulation inside the tube is estimated, collector efficiency, effect of
tube tilt angles, incidence angle modifier, The solar heating system is investigated under different loads pattern (i.e
closed and open flow) to evaluate the heat loss coefficient

... Show More
View Publication Preview PDF
Crossref (17)
Crossref