Profound maternal hemodynamic changes occur in order to satisfy the demands of a growing foetus. Early in pregnancy, peripheral vascular resistance (PVR) lowers, generating a considerable rise in cardiac output. Many parameters are employed for measuring the LV systolic function with different echocardiographic modalities including: M-Mode echocardiography, two-dimensional echocardiography, three-dimensional echocardiography, tissue doppler imaging.
This paper presents the design and analysis of composite right left hand (CRLH) electromagnetic bandgap (EBG) structure. The proposed unit cell is consistent of a dielectric substrate with dimensions of 5×5×1 mm 3 made of FR4-Epoxy with εr = 4.4 underneath of a conductive patch with dimensions of 4.4×4.4mm 2 . The unit cell is structured to perform a negative permittivity (ε) and negative permeability (µ) in different bands. The proposed unit cell is developed to 5G systems in the sub-6GHz bands. In this work, a complete analysis of the unit cell in terms of Sparameters, constitutive parameters and refraction index are evaluated using HFSS simulation package based on Finite Element Method (FEM).
the main of this paper is to give a comprehensive presentation of estimating methods namely maximum likelihood bayes and proposed methods for the parameter
Diabetes mellitus, with adverse neonatal events are challenging issues to all obstetricians and pediatricians, where uric acid could play a vital role. We aimed to assess the relationship and prognostic benefits of serum uric acid measured at about 20 weeks’ gestation in normotensive pregnancy, with subsequent maternal diabetes, and neonatal complications. All singleton normotensive pregnant women with normal blood glucose, serum creatinine, and weight before pregnancy, whom attended Medical City Hospital, Department of Obstetrics and Gynecology in Baghdad, were involved and regarded as the case group, on the condition that their serum uric acid measured at 20 weeks’ gestation > 3 mg/dl, but if ≤ 3 mg/dl, they would be regi
... Show MoreBackground: Spleen is a hemopoietic organ which is capable of supporting elements of different systems. It is affected by several groups of diseases; inflammatory, hematopoietic, reticuloendothelial proliferation, portal hypertension and storage diseases. Ultrasound (US) may detect mild splenomegaly before it is clinically palpable. Knowledge of the normal range of spleen size in the population being examined is a prerequisite. Racial differences in splenic length could result in incorrect interpretation of splenic measurements and such differences would make it difficult to standardize expected splenic length and to determine non- palpable splenic enlargement.Objectives: To measure the normal values of splenic lengthin Iraqi subjects an
... Show MoreDC planar sputtering system is characterized by varying discharge potential of (250-2000 volt) and Argon gas pressures of (3.5×10-2 – 1.5) mbar. The breakdown voltage for silver electrode was studied with a uniform electric field at different discharge distances, as well as plasma parameters. The breakdown voltage is a product of the Argon gas pressure inside the chamber and gab distance between the electrodes, represent as Paschen curve. The Current-voltage characteristics curves indicate that the electrical discharge plasma is working in the abnormal glow region. Plasma parameters were found from the current-voltage characteristics of a single probe positioned at the inter-cathode space. Typical values of the electron temperature an
... Show MoreIn this paper, point estimation for parameter ? of Maxwell-Boltzmann distribution has been investigated by using simulation technique, to estimate the parameter by two sections methods; the first section includes Non-Bayesian estimation methods, such as (Maximum Likelihood estimator method, and Moment estimator method), while the second section includes standard Bayesian estimation method, using two different priors (Inverse Chi-Square and Jeffrey) such as (standard Bayes estimator, and Bayes estimator based on Jeffrey's prior). Comparisons among these methods were made by employing mean square error measure. Simulation technique for different sample sizes has been used to compare between these methods.
This paper is interested in comparing the performance of the traditional methods to estimate parameter of exponential distribution (Maximum Likelihood Estimator, Uniformly Minimum Variance Unbiased Estimator) and the Bayes Estimator in the case of data to meet the requirement of exponential distribution and in the case away from the distribution due to the presence of outliers (contaminated values). Through the employment of simulation (Monte Carlo method) and the adoption of the mean square error (MSE) as criterion of statistical comparison between the performance of the three estimators for different sample sizes ranged between small, medium and large (n=5,10,25,50,100) and different cases (wit
... Show MoreAn experiment during the two seasons 2019, 2020. The experiment conducted according to Split Plot Design by two factors; the first was addition Nano NPK with five levels (control, addition 7.5 g.plant-1, addition 15 g.plant-1, spray 1 g.L-1, spray 2 g.L-1). The second factor was four levels of Mineral NPK which were (control, 50 g.plant-1, 100 g.plant-1, 50 g.plant-1+1.5 g.L-1) respectively. N3 (spray 1 g.L-1 ) increased plant height, stem diameter first season, branch number se
Vitamin D is a fat-soluble vitamin with antioxidant and DNA protecting properties , Levofloxacin is a member of the fluoroquinolone drug class, Its broad-spectrum bactericidal effect affects both Gram-positive and Gram-negative bacteria.
The goal of the study is to analyze the haematology analysis in rats received levofloxacin and show the preventive impact of vitamin D3 by analyzing the haematology parameters: packed cell volume (PCV), mean corpuscular hemoglobin concentration(MCHC),haemoglobin (HB), red blood cell (RBC), mean corpuscular volume (MCV),meancorpuscular haemoglobin(MCH), WBC ,differential WBC, and Platelets.
The study included 42 rats divided into 6 groups each group 7 rats. group I negative control
... Show More