The seismic can be threatened the stability of the flexible body of the earth dam and can cause completely damaged or deformation on their embankment. Therefore, a geotechnical engineer needs to know the effect of earthquakes on earth structures. The change in the seismic zone that recently Iraq affected is the reason for this research, in general, in 2017, the whole of Iraq, and in particular the region, where the Al-Wand earth dam (the subject of the study) is located, was exposed to several earthquakes. This research project mainly aims to study the behavior of Al-Wand earth dam under seismic load in different conditions by simulating Al-Wand earth dam through numerical modeling and study the influence of water reservoir level, earthquake peak acceleration, and duration. This paper includes an analytical study of the effect of this earthquake on Al-wand earth dam, using the quake/w program, which is a sub-program of geo-studio, also the stability of the dam was studied under the influence of earthquakes of different intensity, and a review of the impact of different water levels on the stability of the body dam. Where the response of the Al-wand dam was analyzed to earthquakes at the normal and the maximum water level, and by using a quake that may have been exposed to Iraq in 2017 and used the time of 100 seconds and using an acceleration of 0.02g, 0.03g, 0.05g measured by units of ground acceleration to identify the behavior of displacements, effective stress and pore water pressure during the earthquake.
This research discusses the verbal follow phenomenon in Al-Amali Abi Al-Qali’s book (seq.356 Hijri). It aims to limit the examples of this phenomenon in the book, and examine it phonologically. Accordingly, the researcher adopted the analaytical descriptive approach, taking into account Al-Rawi’s letter when ordering the verbal follow-based examples, and the order they took in the book in question. The purposes behind this phonological study of verbal follow in Al-Amali’s book are to: reach the sounds which Arabs prefer in the process of following, confirm different beautiful and desirable senses, have easy and speedy pronunciation, maintain harmony between adjacent sounds, count the sounds that occur at the beginning of the
... Show MoreThe present work divided into two parts, first the experimental side which included the
measuring of the first natural frequency for the notched and unnotched cantilever composite beams
which consisted of four symmetrical layers and made of Kevlar- epoxy reinforced. A numerical
study covers the effect of notches on the natural frequencies of the same specimen used in the
experimental part. The mathematical model for the beam contains two open edges on the upper
surface. The effect of the location of cracks relative to the restricted end, depth of cracks, volume
fraction of fibers and orientation of the fiber on the natural frequencies are explored. The results
were calculated using the known engineering program (ANSY
ABSTRACT this paper extends the literature on the elements and effect of financial literacy by investigating the elements of financial literacy and the impact of financial literacy on financial inclusion and savings. This research confirms the results of researches of other economies but exposes some dissimilarities as well. The principal factors of financial literacy are discovered to be government efficiency, educational level, income, economic performance and infrastructure. Both education levels and financial literacy are found to be meaningfully and positively linked to financial inclusion and savings in G20 economies
Polymethylmethacrylate film (PMMA) of thickness 75 μm was evaluated Spectrophotometrically for using it as a low-doses gamma radiation dosimeter. The doses were examined in the range 0.1 mrad-10 krad. Within an absorption band of 200-400 nm, the irradiated films showed an increase in the absorption intensity with increasing the absorbed doses. Calibration curves for the changes in the absorption differences were obtained at 218, 301, and 343 nm. At 218 nm the response for the absorbed doses is a linear in the range 10 mrad- 10 krad. Hence it is recommended to be adopted as an environmental low doses dosimeter
Joint diseases, such as osteoarthritis, induce pain and loss of mobility to millions of people around the world. Current clinical methods for the diagnosis of osteoarthritis include X-ray, magnetic resonance imaging, and arthroscopy. These methods may be insensitive to the earliest signs of osteoarthritis. This study investigates a new procedure that was developed and validated numerically for use in the evaluation of cartilage quality. This finite element model of the human articular cartilage could be helpful in providing insight into mechanisms of injury, effects of treatment, and the role of mechanical factors in degenerative
conditions, this three-dimensional finite element model is a useful tool for understanding of the stress d
In this paper, we investigate the behavior of the bayes estimators, for the scale parameter of the Gompertz distribution under two different loss functions such as, the squared error loss function, the exponential loss function (proposed), based different double prior distributions represented as erlang with inverse levy prior, erlang with non-informative prior, inverse levy with non-informative prior and erlang with chi-square prior.
The simulation method was fulfilled to obtain the results, including the estimated values and the mean square error (MSE) for the scale parameter of the Gompertz distribution, for different cases for the scale parameter of the Gompertz distr
... Show MoreAbstract
Robotics manipulators with structural flexibility provide an attractive alternative to rigid robotics manipulators for many of the new and evolving applications in robotics. In certain applications their use is unavoidable. The increased complexity in modeling and control of such manipulators is offset by desirable performance enhancements in some respects. In this paperthe single- link flexible robotics manipulator was designed and implemented from Perspex and designed with 0.5 m length , 0.02 m width and with 0.004 m thickness with mass located at the tip. There are four subsystems; motion, control, accelerometer and gyro and a host computer subsystem. The work principle of single-link robotics manipul
... Show More