Preferred Language
Articles
/
OReAj5IBVTCNdQwCaLfE
Comparative evaluation of pharmacokinetic parameters between a pure nisoldipine suspension and a nisoldipine-loaded bilosome suspension
...Show More Authors

Bilosomes are nanocarriers that contain bile salts in their vesicular bilayer, thereby enhancing their flexibility and durability in the gastrointestinal tract. Unlike conventional vesicular systems they provide distinct advantages such as streamlined manufacturing procedures, cost efficiency, and improved stability. The main objective of this study was to attain a comparison of the pharmacokinetic parameters of nisoldipine (NSD) after administering an ordinary NSD suspension and an NSD-loaded bilosome suspension. The study used 60 Swiss albino rats weighing 200±15 g and divided into two groups (n=30 each). A dose of 2.2 mg/kg of NSD was administered from the ordinary NSD suspension to the rats of the first group and the same dose of NSD-loaded bilosome suspension was administered to the rats of the second group. NSD levels were determined in the rat plasma by using high-performance liquid chromatography. Our results showed that the Cmax, the Tmax, and the AUC0-36 were 51.47±0.94 ng/mL, 2±0.3 h, and 323.33±21 ng×h/mL for the pure suspension, and 116.41±1.22 ng/mL, 4±0.7 h, and 916±64.09 ng×h/mL for the bilosome suspension, respectively. The maximum concentration was significantly different between the pure and the bilosomal preparation (P<0.05), while the relative bioavailability of the pure suspension was 2.9 times that of the bilosomal suspension, 36 h after a single-dose NSD administration. In conclusion, the prepared bilosomal suspension enhanced the bioavaila¬bility of NSD, and could be considered as a vital delivery system.

Scopus Crossref
View Publication
Publication Date
Sat Oct 20 2018
Journal Name
Journal Of Economics And Administrative Sciences
The effect of The Organizational Agility On High Performance ( Applied Search )
...Show More Authors

Abstract

The current research aims to know  the  reality of the  research's coefficients, to know  correlation and effectiveness  between  the  organizational  Agility  and high performance . The current research  has been applied on  the official banks , including  a sample of  senior administration  members  (120) ; besides , the research has used questionnaire  that being considered as the main tool for gathering  information  and data . It includes  59 questions  in addition to  the personal interviews  program  as to support  the questionnaire and to fulfill a great deal of reality. It has been anal

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Calculating heterogeneity of Majnoon Field/Hartha Reservoir using Lorenz Coefficient method
...Show More Authors
Abstract<p>One of the principle concepts to understand any hydrocarbon field is the heterogeneity scale; This becomes particularly challenging in supergiant oil fields with medium to low lateral connectivity and carbonate reservoir rocks.</p><p>The main objectives of this study is to quantify the value of the heterogeneity for any well in question, and propagate it to the full reservoir. This is a quite useful specifically prior to conducting detailed water flooding or full field development studies and work, in order to be prepared for a proper design and exploitation requirements that fit with the level of heterogeneity of this formation.</p><jats></jats> ... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
The study of thermal description for non-thermal plasma needle system
...Show More Authors

Cold plasma is a relatively low temperature gas, so this feature enables us to use cold plasma to treat thermally sensitive materials including polymers and biologic tissues. In this research, the non-thermal plasma system is designed with diameter (3 mm, 10 mm) Argon at atmospheric pressure as well as to be suitable for use in medical and biotechnological applications.
The thermal description of this system was studied and we observed the effect of the diameter of the plasma needle on the plasma, when the plasma needle slot is increased the plasma temperature decrease, as well as the effect of the voltages applied to the temperature of the plasma, where the temperature increasing with increasing the applied voltage . Results showed t

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Nov 11 2020
Journal Name
The Abu Dhabi International Petroleum Exhibition & Conference, Abu Dhabi, Uae, November 2020. Paper Number: Spe-203090-ms
Stress-Dependent Petrophysical Properties of High Heterogeneous Carbonate Tight Oil Reservoirs
...Show More Authors

As a reservoir is depleted due to production, pore pressure decreases leading to increased effective stress which causes a reduction in permeability, porosity, and possible pore collapse or compaction. Permeability is a key factor in tight reservoir development; therefore, understanding the loss of permeability in these reservoirs due to depletion is vital for effective reservoir management. The paper presents a case history on a tight carbonate reservoir in Iraq which demonstrates the behavior of rock permeability and porosity as a function of increasing effective stress simulating a depleting mode over given production time. The experimental results show unique models for the decline of permeability and porosity as function effective str

... Show More
View Publication
Publication Date
Sun Mar 20 2016
Journal Name
Al-academy
Indicative coding of the actor’s performance in the Iraqi theater show
...Show More Authors

View Publication
Crossref
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
Modelling of electron trajectories inside SEM chamber concerning mirror effect phenomenon
...Show More Authors

A computational investigation is carried out to describe the behaviour of reflected electrons upon a charged insulator sample and producing mirror effect images. A theoretical expression for the scanning electron path equation is derived concerning Rutherford scattering and some electrostatic aspects. The importance of the derived formula come from its correlation among some of the most important parameters that controls the mirror effect phenomena. These parameters, in fact, are the trapped charges, incident angle and the scanning potential which investigated by considering its influences on the incident electrons. A pervious experimental operation requirements are adopted for operating the introduced expression. However, the obtained r

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Feb 29 2012
Journal Name
Al-khwarizmi Engineering Journal
Effect of Solid Properties on Axial Liquid Dispersion in Bubble Column
...Show More Authors

Experiments were conducted to study axial liquid dispersion coefficient in slurry bubble column of 0.15 m inside diameter and 1.6 m height using perforated plate gas distributor of 54 holes of a size equal to 1 mm diameter and with a 0.24 free area of holes to the cross sectional area of the column. The three phase system consists of air, water and PVC used as the solid phase. The effect of solid loading (0, 30 and 60 kg/m3) and solid diameter (0.7, 1.5 and 3 mm) on the axial liquid dispersion coefficient at different axial location (25, 50 and 75 cm) and superficial gas velocity covered homogeneous-heterogeneous flow regime (1-10 cm/s) were studied in the present work. The results show that the axial liquid dispersion coeffic

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrochemical removal of copper from synthetic wastewater using rotating cylinder electrode
...Show More Authors

The performance of a batch undivided electrochemical reactor with a rotating cylinder electrode of woven-wire (60 mesh size), stainless steel 316, is examined for the removal of copper from synthetic solution of o.5 M sodium chloride containing 125 ppm at pH ≈ 3.5. The effect of total applied current, rotation speed on the figures of merit of the reactor is analyzed. For an applied current of 300 mA at 100 rpm, the copper concentration decreased from 125 to  mg l-1 after 60 min of electrolysis with a specific energy consumption of 1.75 kWh kg-1 and a normalized space velocity of 1.62 h-1. The change in concentration was higher when the total applied currents were increased because of the turbulence

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2009
Journal Name
Journal Of Nonlinear Optical Physics &amp; Materials
SPECTRAL WIDTH VARIATION OF ULTRASHORT LASER PULSES IN MONOMODE OPTICAL FIBERS
...Show More Authors

Femtosecond laser pulse propagation in monomode optical fibers is demonstrated and investigated numerically (by simulations) and experimentally in this paper. A passively mode locked Nd:glass laser giving a pulse duration of about 200 fsec at 1053 nm wavelength and 120 mW average optical power with 100 MHz repetition rate is used in the experimental work. Numerical simulations are done by solving the nonlinear Schrödinger equation with the aid of Matlab program. The results show that self phase modulation (SPM) leads to compression of the spectral width from 5 nm to 2.1 nm after propagation of different optical powers (34, 43, 86 and 120 mW) in fibers of different length (5, 15, 35 m). The varying optical powers produced a varying

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Diyala Journal Of Engineering Sciences
Generation of entangled photons by short coherence length violet diode laser
...Show More Authors

Pumping a BBO crystal by a violet diode laser with a wavelength of (405 nm) output power of (24 mW) and a line width of (3nm) was employed to generate entangled photons with a wavelength of 810 nm by achieving type II phase matching conditions.The coincidence count rate obtained in this experiment was in the range of (18000) counts/s. Two BBO crystals with different thicknesses of (4 mm and 2 mm) were tested, where maximum count rates of about (18000) counts/s was obtained with a (5*5*2) mm BBO crystal where the short coherence time for the pumping source was tolerated by using shorter BBO crystals. Also, the effect of compensating crystal on the walk-off effect was studied. The coincidence count rates were increased by using these crystal

... Show More
View Publication