Background: Acromegaly is an uncommon, chronic, debilitating condition characterized by hyperinsulinism, insulin resistance, diabetes and prediabetes. One possibility for managing acromegaly's questionable influence on glucose homeostasis is the somatostatin analogues. Aim: To analyze the frequency and risk factors for impaired glucose homeostasis in acromegaly patients treated with depot long-acting octreotide (octreotide LAR), as well as the relationship between risk and treatment duration. Methods: The study included 52 Iraqi adults with acromegaly receiving octreotide LAR. Demographic, anthropometric, and clinical data were collected, as well as the duration of Octreotide LAR administration. Growth hormone, IGF-1, and adenoma size were reported retrospectively from patient data. The glycemic state was assessed and classified as DM, prediabetes, or normal. Results: The prevalence of DM was 39% and prediabetes was 40%, with the exception of being male, which was substantially related with prediabetes. DM and octreotide LAR use had a non-significant correlation. However, octreotide use altered 13% of patients from normal glycemic to prediabetes, with no correlation to treatment duration. Other than hypertension and a family history of diabetes, no other variables were found to be significant. Conclusion: Acromegaly patients have abnormal glucose metabolism, which is associated with prediabetes owing to octreotide LAR medication. Hypertension and family history of diabetes are risk factors.
In this work, effects of using different evaporative cooling pads (ECPs) on the energetic and exergetic efficiency of a direct evaporative air cooler (DEAC) have been theoretically and experimentally investigated. Three types of ECPs were used, i.e., honeycomb cellulose cooler pad (HCCP), shading-cloth cooler pad (SCCP), and aspen wood wool cooler pad (AWWCP). For SCCP and AWWCP, a 3-cm pad thickness was used, while for the HCCP, three different values of pad thickness were used, i.e., 3, 5, and 7 cm. Tests were carried out using air velocities of 8, 14, and 19 m/s, measured at the DEAC outlet. Engineering equation solver (EES) used for performing the required calculations of the various parameters affecting the thermal performance of the D
... Show MoreThe pretreatment process can be considered one of the important processes in wastewater treatment, especially coagulation process to decrease the strength of many pollutants. This paper focused on using powdered date seeds as natural coagulant in addition to chemical coagulants (alum and ferric chloride) to find the optimum dosage of each coagulant that makes efficient removal of turbidity and chemical oxygen demand (COD) from domestic wastewater as a pretreatment process, then finding the optimum combined dosages of date seeds with alum, date seeds with ferric chloride that make efficient removal for both pollutants. Concerning turbidity, the optimum dosage for date seeds, alum and ferric chloride were 40 mg/l (79%), 70
... Show MoreAn experimental and theoretical works were carried out to model the wire condenser in the domestic refrigerator by calculating the heat transfer coefficient and pressure drop and finding the optimum performance. The two methods were used for calculation, zone method, and an integral method. The work was conducted by using two wire condensers with equal length but different in tube diameters, two refrigerants, R-134a and R-600a, and two different compressors matching the refrigerant type. In the experimental work, the optimum charge was found for the refrigerator according to ASHRAE recommendation. Then, the tests were done at 32˚C ambient temperature in a closed room with dimension (2m*2m*3m). The results showed that th
... Show MoreThe problem of generated waste as a result of the implementation of construction projects, has been aggravated recently because of construction activity experienced by the world, especially Iraq, which is going through a period of reconstruction, where construction waste represents (20-40%) of the total generated waste and has a negative effect on the environment and economic side of the project. In addition, the rate of consumpted amounts of natural resources are estimated to be about 40% in the construction industry, so it became necessary to reduce waste and to be manage well. This study aims to identify the key factors affecting waste management through the various phases of the project, and this is accom
... Show More