Preferred Language
Articles
/
NheFP48BVTCNdQwC1GY8
A flow analysis system integrating an optoelectronic detector for the quantitative determination of active ingredients in pharmaceutical formulations
...Show More Authors

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Economics And Administrative Sciences
The impact of the integrative role of the Business Intelligence system and Knowledge Conversion Processes in Building a learning organization A field research in Korek telecom company in Baghdad city
...Show More Authors

Purpose:  The research aims to explore the impact Business Intelligence System (BIS) and Knowledge Conversion Processes (KCP) in the Building Learning Organization (LO) in KOREK Telecom Company in Baghdad city.

Design/methodology/approach: in order to achieve the objectives of the research has been the development of a questionnaire prepared for this purpose and then has tested the search in the telecommunications sector, representatives of one of the telecommunications companies in Baghdad city, has therefore chosen KOREK Telecom company as a sample for research, and the choice was based on the best standard international companies to serve mobile communications in terms o

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 16 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Hard palate bone density and thickness determination using CT scan and their relationships with body compositions measured by bioelectrical impedance analysis for Iraqi adult sample
...Show More Authors

Background: This study was conducted to evaluate the hard palate bone density and thickness during 3rd and 4th decades and their relationships with body mass index (BMI) and compositions, to allow more accurate mini-implant placement. Materials and method: Computed tomographic (CT) images were obtained for 60 patients (30 males and 30 females) with age range 20-39 years. The hard palate bone density and thickness were measured at 20 sites at the intersection of five anterioposterior and four mediolateral reference lines with 6 and 3 mm intervals from incisive foramen and mid-palatal suture respectively. Diagnostic scale operates according to the bioelectric impedance analysis principle was used to measure body weight; percentages of body fa

... Show More
View Publication Preview PDF
Publication Date
Mon May 04 2020
Journal Name
Environmental Engineering Research
Experimental and modeling study of water defluoridation using waste granular brick in a continuous up-flow fixed bed
...Show More Authors

Contamination of surface and groundwater with excessive concentrations of fluoride is of significant health hazard. Adsorption of fluoride onto waste materials of no economic value could be a potential approach for the treatment of fluoride-bearing water. This experimental and modeling study was devoted to investigate for the first the fluoride removal using unmodified waste granular brick (WGB) in a fixed bed running in continuous mode. Characterization of WGB was carried out by FT-IR, SEM, and EDX analysis. The batch mode experiments showed that they were affected by several parameters including contact time, initial pH, and sorbent dosage. The best values of these parameters that provided maximum removal percent (82%) with the in

... Show More
Scopus (13)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2014
Journal Name
The Scientific World Journal
Heat Transfer Enhancement of Laminar Nanofluids Flow in a Circular Tube Fitted with Parabolic-Cut Twisted Tape Inserts
...Show More Authors

Numerical investigation has been carried out on heat transfer and friction factor characteristics of copper-water nanofluid flow in a constant heat-fluxed tube with the existence of new configuration of vortex generator using Computational Fluid Dynamics (CFD) simulation. Two types of swirl flow generator: Classical twisted tape (CTT) and Parabolic-cut twisted tape (PCT) with a different twist ratio (y= 2.93, 3.91 and 4.89) and different cut depth (w= 0.5, 1.0 and 1.5 cm) with 2% and 4% volume concentration

... Show More
View Publication
Scopus (34)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Sun Sep 03 2017
Journal Name
Baghdad Science Journal
Calculation of Lambda Doubling for 7LiH1 molecule Using the System band emission for electronic transmissions
...Show More Authors

The A2?u-X1?g+ emission band system of 7LiH1 molecule has been calculated for Lambda doubling. The relation between wave number ?p , ?Q , ?R conducted the energies of the state of rotation F (J), and (J + 1) with rotational quantum number J, respectively, of 7LiH1 molecule for statehood A2?u using the rotation, fixed vibrational states of both the ground and raised crossovers vibrational against ???= 0 to V ' = 0-4using rotational levels J = 0 to J = 20 have found.

View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Dec 29 2020
Journal Name
Iraqi Journal Of Science
ANALYSIS of INTERFERENCE PATTERN of the FIBER INTERFEROMETER as a MOTION SENCOR
...Show More Authors

The production and analysis of an optimal interference pattern for the optical fiber interferometer of a 193.1THz continuous laser source was simulated by comparing the spectral spectroscopy of the two arms of interferometer to be used as a heterodyne detection in sensing the body range, speed, and direction of movement by delaying the time between the arms.

     The study showed that the fringe pattern can be sensed a range by the free spectral range FSR and the velocity by the fringe separation FS and the direction by the fringe spatial frequency FSF.

View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Oct 20 2020
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Surface Contamination and Dose Rate Verification of Fertilizers common in Iraqi Plantations using RadEye B20 Detector
...Show More Authors

Twenty three samples of granular chemical fertilizers and organic fertilizers commonly utilized in Iraqi ranches were collected. The samples were prepaid and stored in a Marinelli beaker to measure; dose rate, general count rate and surface contamination of the samples using the RadEye B20 detector, firstly with shield, secondly without the shield to estimate the effect of shielding on the measurements. The results showed that using shield made a significant decrease in the radiation measurements reached about 25%. However the mean value of surface contamination, dose rate and general count rate with shield were 0.54Bq/cm2, 0.65µsv/h, and 0.28Cps respectively, and without shield being 0.34Bq/cm2, 1.33µsv/h, and 1.52Cps respectively

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu May 28 2020
Journal Name
Iraqi Journal Of Science
Development of an Attendance System Based on Cloud / Fog Computing with Data Recovery Capability
...Show More Authors

Given the high importance of attendance for university students, upon which the possibility of keeping or losing their places in the course is based, it is essential to replace the inefficient manual method of attendance recording with a more efficient one.  To handle this problem, technology must be introduced into this process. This paper aims to propose an automatic attendance system based on passive Radio Frequency Identification (RFID), fog, and cloud computing technologies (AASCF). The system has three sides. The first one, which is the Client-side; works on collecting the attendance data then sending a copy from it. The second side, which is the Server-side, works on calculating an absence ratio of all the students during the

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Laser Detection and Tracking System Using an Array of Photodiodes with Fuzzy Logic controller
...Show More Authors

In this work laser detection and tracking system (LDTS) is designed and implemented using a fuzzy logic controller (FLC). A 5 mW He-Ne laser system and an array of nine PN photodiodes are used in the detection system. The FLC is simulated using MATLAB package and the result is stored in a lock up table to use it in the real time operation of the system. The results give a good system response in the target detection and tracking in the real time operation.

View Publication Preview PDF
Publication Date
Mon Oct 02 2023
Journal Name
Journal Of Engineering
Controlling the Unbalanced Voltages of a Series-Connected Lead-Acid Batteries in a PV Power Storage System using Dynamic Capacitor Technique
...Show More Authors

Lead-acid batteries have been used increasingly in recent years in solar power systems, especially in homes and small businesses, due to their cheapness and advanced development in manufacturing them. However, these batteries have low voltages and low capacities, to increase voltage and capacities, they need to be connected in series and parallel. Whether they are connected in series or parallel, their voltages and capacities must be equal otherwise the quality of service will be degraded. The fact that these different voltages are inherent in their manufacturing, but these unbalanced voltages can be controlled. Using a switched capacitor is a method that was used in many methods for balancing voltages, but their respons

... Show More
View Publication Preview PDF
Crossref