Surfaces quality is one of the most specified customer requirements for machine parts. The major indication of surfaces quality on machined parts is surface roughness. The research aim is to study the cutting conditions and their effects on the surface roughness. This paper utilizes regression models to predict surface roughness over the machining time for variety of cutting conditions in turning. In the experimental part for turning, different types of materials (Aluminum alloy, Copper alloy, and Gray cast iron) were considered with different cutting speed ( ) and feed rate ( ). A mathematical Model depending on statistical-mathematical method between surface roughness (Rz ) and cutting condition ( , ) were derived, for the three materials. The matrix of test conditions included cutting speeds of the 16, 30, 45 and 60 m/min, feed rates of 0.17, 0.35 and 0.7 mm/rev while the depth of cut has been kept constant. The effect of cutting parameters on surface roughness is evaluated and the optimum cutting condition for minimizing the surface roughness is determined. Mathematical model has been established between the cutting conditions and surface roughness using regression. The predicted values and measured values are fairly close, which indicates that the developed model can be effectively used to predict the surface roughness in the turning machining. As the results of this work, the mathematical models were used in predicting surface roughness, can be used in CAD-CAM manufacturing systems, this mathematical model helps engineer to reduce the efforts. Mathematical models shows that the decreasing in the feed rate resulted in better surface roughness and increasing cutting speed resulted in better surface roughness. The goal of this work is to identify a relationship between experimental results and theoretical model, and study the proper process values for machining, to increasing the rates for raising the quality (better surface roughness).
Objective: Evaluation of the poly ether keton keton polymer (PEKK) coating material on the commercial pure titanium disks (CP Ti) with or without laser surface structuring. Design: In vitro experimental study of PEKK polymer coated material on the CP Ti disks with or without laser surface structuring. Materials and methods: coating the surface of the commercial pure titanium (CP Ti) disks with PEKK polymer was performed via using frictional mode CO2 laser, then the samples disks analyzed by using FESEM. Results: the FESEM reveal good adherence and distribution of the PEKK coated material over the CP Ti substrate by using the frictional mode CO2 laser at 2 watt and 6 ms pulse duration. Conclusion: the frictional mode CO2 laser considered an
... Show MoreTheoretical calculations are achieved to study the effect of different deuterium pressures on various characteristics parameters for PF400J plasma focus using an international computer code. Axial and radial velocities, voltage tube, plasma temperatures, and neutron yields at different operating deuterium pressures are computed. Neutron emission has been calculated in the device. The maximum total neutron yield calculated is of the order of and neutrons per shot for entire pressure used. The computed results agree reasonably well with the published neutron yield curves.
The general approach of this research is to assume that the small nonlinearity can be separated from the linear part of the equation of motion. The effect of the dynamic fluid force on the pump structure system is considered vibrates at its natural frequency but the amplitude is determined by the initial conditions. If the motion of the system tends to increase the energy of the pump structure system, the vibration amplitude will increase and the pump structure system is considered to be unstable. A suitable MATLAB program was used to predict the stability conditions of the pump structure vibration. The present research focuses on fluid pump problems, namely, the role played by damping coefficient C, damping factor
... Show MoreThe best optimum temperature for the isolate was 30○C while the pH for the maximum mineral removal was 6. The best primary mineral removal was 100mg/L, while the maximum removal for all minerals was obtained after 8 hrs, and the maximum removal efficiency was obtained after 24 hrs. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/ minute. Inoculums of 5ml/ 100ml which contained 106 cell/ ml showed maximum removal for the isolate.
The aim of the research is to identify both the re-engineering of management processes and the strategic decision-making process in the research community and determine the nature of the correlation between the two variables and know the relationship between them to achieve the research goal. The researcher used a descriptive and analytical method. The research community consists of a group of professors and staff of the College of Education affiliated to the University of Mustansiriya in Baghdad, which their number were (45), the researcher has distributed the forms to all members of the sample, only (3) forms were excluded for invalidity and thus the number of forms approved in the analysis were (42) forms. The rese
... Show MoreAnew mathematical formula was proposed to describe the behavior of the extinction coefficient as a function of ambient temperature and wavelengths for some of infrared materials. This formula was derived depending on some experimental data of transmittance spectrum versus wavelengths for many ambient temperatures. The extensive study of the spectrum characteristics and depending on Bose-Einstein distribution led to derive an equation connecting the extinction coefficient or the absorption coefficient with the ambient temperature and wavelengths of the incident rays. The basic assumption in deriving process is the decreasing in transmittance value with the increasing temperature which is only due to the changing in extinction coeffi
... Show MoreTitanium alloy (Ti-6Al-4V or Gr.23) was widely used as a dental alloy. In the current study, polymerization of eugenol (PE) on Gr.23 titanium alloys was conducted by an electrochemical process before and after being treated by Micro Arc Oxidation (MAO). The formed films were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray diffraction (XRD). The corrosion behavior of Gr.23 alloy in an artificial saliva environment at a temperature range of 293–323 K has been studied and assessed by means of electrochemical polarization and impedance spectroscopy techniques. Three cases are taken into consideration; bare Gr.23, Gr.23 coated by PE, and Gr.23 coated by PE after MAO treatment. The maxi
... Show MoreThis study was designed to look for certain biochemical markers(serum uric acid and serum peroxynitrite) in women presented with obesity and to compare the level of these markers with non-obese women. A total number of 63 women were recruited from outpatients and private clinics to admit in this study. The patients were grouped into non obese women (Group I) and obese women (Group II). The anthropometric and blood pressure were determined and venous blood was obtained from each patient for determination of C-reactive protein, uric acid and peroxynitrite. The results showed that there were no significant differences in age or in concomitant or associated diseases in both groups except rheumatoid arthritis which account 80% of group I and 25%
... Show More