Preferred Language
Articles
/
NeaKZZwBmraWrQ4do0ka
Antimicrobial behavior of nanocoated orthodontic micro-implants: An in vitro study
...Show More Authors
OBJECTIVE:

The need to overcome the failure of orthodontic micro-implants which might reach to 30% has led to the development of different methods, one of which is nanoparticle deposition.

AIM OF STUDY:

To evaluate the anti-microbial efficiency of TiO2 and ZnO nanoparticles (NP) when used as a coating for orthodontic micro-implants.

METHODS:

Thirty titanium alloy micro-implants were used in the presented study. They were divided into three groups according to the coating method and the coating materials used: the control group without surface coating; the titanium dioxide (TiO2)-coated group, in which direct current (DC) spattering was used to coat the micro-implants with a TiO2 layer; and the TiO2 and zinc oxide (TiO2ZnO)-coated group, in which the micro-implants were coated with a TiO2 layer via direct current (DC) spattering and a zinc oxide (ZnO) layer via laser vacuum. The micro-implant surfaces were characterized using scanning electron microscopy (SEM) and an energy-dispersive spectrometer (EDS). The antibacterial susceptibility was assessed using gram-positive and gram-negative bacteria.

RESULTS:

SEM and EDS tests confirmed the coating of the micro-implants in the TiO2- and TiO2ZnO-coated groups. The micro-implants in the TiO2- and TiO2ZnO-coated groups demonstrated higher antibacterial ability than the control group.

CONCLUSION:

This study demonstrated the significance of improving the surface of orthodontic micro-implants by coating them with TiO2 and ZnO nanoparticles to improve osseointegration and prevent biofilm formation.

Scopus Crossref
View Publication
Publication Date
Fri Mar 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Bacterial Contamination of Orthodontic Arch wire
...Show More Authors

Background: The microorganisms can impend the life of health care professional and particularly the dental practitioners. They can be transmitted by different ways like airborne and droplet transmission. The current study was carried out to identify whether the arch wires that received from the manufactures are free from microbial contamination and to determine the bacterial species attached to the arch wires. Materials and Methods: This study involved eighty samples, consisted of two types of arch wires (nitinol and stainless-steel) from four companies (3M, G&H, Jiscop, OrthoTechnology). These wires inserted in a plane tube that contains 10 -ml of (Tris [tris(hydroxymethyl)aminomethane] and EDTA (ethylenediaminetetraacetic acid) tri

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Mon Feb 23 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Ions release from fixed orthodontic appliance in two different mouthwashes
...Show More Authors

Background: Metal ions can be released from metallic orthodontic appliances due to corrosion in the oral cavity; prophylactic mouthwashes may have an effect on ion release from orthodontic wires. Materials and Methods: Thirty six orthodontic sets of half maxillary fixed appliance with 2 types of arch wires SS and NiTi(Morelli) were constructed and immersed in 2 types of mouthwashes; Claradone (non-fluoridated) and Silver Care (fluoridated) for 28 days at 37°C, then the released Ni and Cr ionswere measured using atomic absorption spectrophotometer and compared statistically. Results: Ni ion release was higher from NiTi wire group than SS wire group for both mouthwashes and also was higher for Silver Care group than for Claradone group.

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 01 1996
Journal Name
Unpublished
Temporomandibular disorders in pretreatment orthodontic patients as related to malocclusion
...Show More Authors

Temporomandibular disorders (TMDs) were investigated in 143 pretreatment orthodontic patients (43 males and 102 females) whose age ranged between 10-25 years at the College of Dentistry, University of Baghdad, Iraq. The study was undertaken to elucidate the prevalence and severity of TMDs in malocclusion patients and to defme the relationships between malocclusion and TMDs. The clinical signs and subjective symptoms were recorded according to the principles introduced by Helkimo (1974b). Subjective symptoms were reported by 65.7% of the patients with 22.40/0 described as severe, and the most common symptoms were TMJ sounds and feeling offatigue. Clinical signs were observed in 81.8% of the sample with 22.4 and 6.3% described as moderate and

... Show More
Preview PDF
Publication Date
Mon Feb 23 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Biomechanical evaluation of porous titanium implants (CpTi) fabricated by powder technology
...Show More Authors

Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um part

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 23 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Postoperative assessment of dental implants by using multi-slice computed tomography
...Show More Authors

Background: Implantology is a fast growing area in dentistry. One of the most common issues encountered in dental implantation procedures is the lack of adequate preoperative planning. Conventional radiography may not be able to assess the true regional three-dimensional anatomical presentation. Multi Slice Computed Tomography provides data in 3-dimentional format offering information on craniofacial anatomy for diagnosis; this technology enables the virtual placement of implant in a 3-Dimensional model of the patient jaw (dental planning). Patients, Material and Methods: The sample consisted of (72) Iraqi patients indicated for dental implant (34 male and 38 female), age range between (20-70) years old. They were examined during a time p

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Synthesis, Characterization and Antimicrobial Activity Study of Some New Substituted Benzoxazole Derivatives
...Show More Authors

This research included the preparation of 2-mercaptobenzoxazole (N1) by the reaction of ortho-aminophenol with carbon disulfide in an alcoholic potassium hydroxide solution. The 2-mercapto benzoxazole (N1) was then treated with hydrazine to obtain the 2-hydrazino benzoxazole (N2). A number of hydrazones (N3-N5) were prepared through the reaction of N2 with different benzaldehydes. The compound (N6) was also prepared whereby the ring closing of hydrazone (N3) using chloroacetylchloride, while the compound (N7) was prepared by treating 2-hydrazino benzoxazole with acetylacetone. When the compound (N1) was treated with formaldehyde, it afforded the compound (N8). Also, the N9 was obtained from the reaction of N1 with chloroacetic acid in th

... Show More
View Publication Preview PDF
Scopus (17)
Crossref (17)
Scopus Crossref
Publication Date
Sat Sep 01 2007
Journal Name
Al-khwarizmi Engineering Journal
Parametric study of thermal behavior of thrust chamber cooling channels
...Show More Authors

A numerical investigation is adopted for two dimensional thermal analysis of rocket thrust chamber wall (RL10), employing finite difference model with iterative scheme (implemented under relaxation factor of 0.9 for convergence) to compute temperature distribution within thrust chamber  wall (which is composed of Nickel and Copper layers). The analysis is conducted for different boundary conditions: only convection boundary conditions then combined radiation, convection boundary conditions also for  different aspect ratio (AR) of cooling channel. The results show that Utilizing cooling channels of high aspect ratio leads to decrease in temperature variation across thrust chamber wall, while no effects on heat transferred to the

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 01 2022
Journal Name
Journal Of Molecular Structure
Interaction behavior of curcumin encapsulated onto functionalized SBA-15 as an efficient carrier and release in drug delivery
...Show More Authors

In this work, mesoporous silica SBA-15 was prepared and functionalized with amine groups (i.e., NH2) to form NH2/SBA-15. The curcumin (CUR) was encapsulated into the surface and pore of NH2/SBA-15 to create CUR@NH2/SBA-15 as an efficient carrier in drug delivery systems (DDSs). The three samples (i.e., SBA-15, NH2/SBA-15, and CUR@NH2/SBA-15) were characterized. The study investigated the effect of the carrier dose, initial CUR concentration, pH, and contact time on the CUR loading efficiency (DLE%) via adsorption. The best DLE% for the SBA-15 and NH2/SBA-15 were found to be 45% and 89.7%, respectively. The Langmuir isotherm had a greater correlation coefficient (R2) of 0.998 for SBA-15. A pseudo-secondorder kinetic model seemed to fit well

... Show More
View Publication
Scopus (91)
Crossref (87)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2018
Journal Name
World Journal Of Pharmacy And Pharmaceutical Sciences
THE ANTIBACTERIAL EFFECT OF FLAXSEED EXTRACT ON SELECTIVE ORAL PATHOGENS - COMPARATIVE IN VITRO STUDY
...Show More Authors

Flaxseed from the flax plant (Linum usitatissimum), which has been cultivated for domestic use since prehistoric times. This study aims to investigate presence of antibacterial effect of flaxseed extract against selected oral pathogen in-vitro.

Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Evaluation the Effects of CO2 Laser on Soft and Hard Tissues (in vitro study)
...Show More Authors

CO2 laser (10.6 μm) is the most often used laser in the oral surgery due to its high absorption by water of the oral tissues. Several benefits of the use of CO2 laser have been reported for oral surgical procedures. This study aims to evaluate the effect of CO2 laser on soft and hard oral tissues (in vitro study). This study was done on fresh tissues from sheep’s head. CO2Surgical Laser with different operation modes was used; 0.2 mm spot size using different laser parameters on the tongue, and bone making holes, incisions and cutting. The depths and widths of holes and incisions were measured using endodontic file under magnification. The speed of incisions was calculated and the required time for cutting was measured using sport clo

... Show More
View Publication Preview PDF