Preferred Language
Articles
/
NRd3SY8BVTCNdQwC5GnF
DETERMINATION OF PORE TYPES AND POROSITY TRENDS USING OF VELOCITY-DEVIATION LOG FOR THE CARBONATE MISHRIF RESERVOIR IN HALFAYA OIL FIELD, SOUTHEAST IRAQ
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Tue Jan 01 2019
Journal Name
Proceedings Of The 17th Laccei International Multi-conference For Engineering, Education, And Technology: “industry, Innovation, And Infrastructure For Sustainable Cities And Communities”
Type Curve Techniques for Hydraulically Fractured Wells in Tight Gas Reservoir
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Malaysian Journal Of Science
DETERMINATION OF URANIUM CONCENTRATIONS IN RICE SAMPLES AVAILABLE IN THE IRAQI MARKET USING THE CR-39 DETECTOR
...Show More Authors

In this study, the results of the uranium concentrations and specific activity in 10 rice samples are described using a solid-state track detector (CR-39). Samples were collected from various local Iraqi markets with different origins (Iraq, India, America, and Thailand). Our findings found that the results of uranium concentration in all studied samples are ranging from (0.55 ± 0.28 to 1.74 ± 0.31) ppm with a weighted average of (1.24 ± 0.99) ppm. Also, results demonstrate that the specific activity values of the studied samples swing between values of (6.88 ± 3.52 and 21.49 ± 3.85) Bq/Kg. The obtained results of the studied rice samples are indicated that it is less than the acceptable limit of those studies established by ma

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Dec 02 2012
Journal Name
Baghdad Science Journal
Determination the Concentration of the Radon in some Drinking Bottled Water in Baghdad using LR-115 Detector
...Show More Authors

In the present study ten samples of bottled water from Baghdad conservative were taken to measure the concentration of radon gas by using nuclear track detector LR-115.The result obtained are varying from(0.033)to(0.007)pCi.l-1and these values are very low than the allowed limits (5) pCi.l-1, and specific activity from bottled water has been calculated which was vary from (0.00027)to(0.00126) Bq.l-1 and these values are very low than allowed limits (0.0123) Bq.l-1 that mean the bottled water was treated with good treatment to decrease the side effect of radon

View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Theoretical And Applied Information Technology
A Survey on the Vein Biometric Recognition Systems: Trends and Challenges
...Show More Authors

Vascular patterns were seen to be a probable identification characteristic of the biometric system. Since then, many studies have investigated and proposed different techniques which exploited this feature and used it for the identification and verification purposes. The conventional biometric features like the iris, fingerprints and face recognition have been thoroughly investigated, however, during the past few years, finger vein patterns have been recognized as a reliable biometric feature. This study discusses the application of the vein biometric system. Though the vein pattern can be a very appealing topic of research, there are many challenges in this field and some improvements need to be carried out. Here, the researchers reviewed

... Show More
Publication Date
Wed May 18 2016
Journal Name
Al-academy
Actor performance features in the types of theatrical silent
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Sun Sep 02 2012
Journal Name
Baghdad Science Journal
Determination of optimal conditions for laccase production by Pleurotus ostreatus using sawdust as solid medium and its use in phenol degradation
...Show More Authors

The ability of four local fungal isolates for extracellular laccase production has been tested with five grams 1:1(w/v) humidified sawdust as substrate in mineral salt medium. After 21 day of incubation at 25±1 ? C and using one mycelial plug (5mm), higher level of laccase activity (0.15U/ml) and specific activity (15U/mg) were observed by Pleurotus ostreatus in comparison with other fungal isolates. The results of optimum conditions for laccase production from selected isolate showed that, the maximum laccase activity (0.55U/ml) and specific activity (55U/mg) were obtained at moisture ratio 1:3 (w/v), using 3 mycelial plugs (5 mm), after 15 days incubation period at 25±1 ? C. The results of phenol degradation by crud laccase revealed th

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jan 05 2025
Journal Name
Al–bahith Al–a'alami
New Recent Trends in Agenda Setting Studies n The Arab World
...Show More Authors

This study aims to examine the main features of the new trends in agenda studies using the secondary analytic approach in analyzing the newest studies in agenda-setting issues from 2007 till 2017, in addition to the quantitative approach.
The researcher has analyzed 110 studies -75 foreign and 35 Arabic - to determine, describe and evaluate the key research trends which came in Arabic and foreign agenda-setting studies. The results confirmed that studies of the agenda theory are increasing steadily worldwide with diversity in the theoretical trends and used research tools. In addition, primary studies focus on content analysis and the survey approach (method). Also, most Arabic agenda-setting studies used the traditional methods and k

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Oct 31 2021
Journal Name
Eastern-european Journal Of Enterprise Technologies
Distinguishing of different tissue types using K-Means clustering of color segmentation
...Show More Authors

Millions of lives might be saved if stained tissues could be detected quickly. Image classification algorithms may be used to detect the shape of cancerous cells, which is crucial in determining the severity of the disease. With the rapid advancement of digital technology, digital images now play a critical role in the current day, with rapid applications in the medical and visualization fields. Tissue segmentation in whole-slide photographs is a crucial task in digital pathology, as it is necessary for fast and accurate computer-aided diagnoses. When a tissue picture is stained with eosin and hematoxylin, precise tissue segmentation is especially important for a successful diagnosis. This kind of staining aids pathologists in disti

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jul 30 2023
Journal Name
Iraqi Journal Of Science
Performance Estimation of Solar Imagery Using Different Types of Atmospheric Turbulence Models
...Show More Authors

     This paper proposed several approaches for estimating the optical turbulence of the Earth’s atmosphere and their effect on solar images’ resolution using ground-based telescopes based on von Kárman, Kolmogorov, and modified von Kárman PSDs models. The results showed a strong correlation coefficient for the modified von Kármán model of atmospheric representation. As can be seen in the case where solar adaptive optics have been properly designed, they typically decrease aberration considerably and provide greatly improved imagery.

View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF
Crossref