Preferred Language
Articles
/
NRYY14cBVTCNdQwCaWor
Theoretical Estimation of Charge Transfer Rate at Some Nitrosyl Complexes
...Show More Authors

The charge transfer at C23H17F8N8O2PRu, C44H30BF4N5O4Ru, C56H52CL5N5OOsP2 and C76H88F80N24O11P10Ru4 nitrosyl complexes are investigation and studies theoretically using the quantum consideration. Charge transfer behavior largely rely to the electric properties of nitrosyl complexes system whose depending on the main important parameters for the transmission rate constant such that: orientation transition energy, overlapping coupling coefficient, driving force energy, height barrier and Temperature T (K). Data results have been evaluated using a MATLAB program. Results show that rate of charge transfer increases due to increases the orientation transition energy.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 01 2020
Journal Name
Journal Of Economics And Administrative Sciences
Fuzzy Robust Estimation For Location Parameter
...Show More Authors

 In this paper, we introduce three robust fuzzy estimators of a location parameter based on Buckley’s approach, in the presence of outliers. These estimates were compared using the variance of fuzzy numbers criterion, all these estimates were best of Buckley’s estimate. of these, the fuzzy median was the best in the case of small and medium sample size, and in large sample size, the fuzzy trimmed mean was the best.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
World Journal Of Dentistry
Assessment of Implant Stability Changes and Success Rate of Narrow Dental Implants
...Show More Authors

Aims: To assess the success rate and implant stability changes of narrow dental implants (NDIs) during the osseous healing period. Materials and methods: This prospective observational clinical study included 21 patients with narrow alveolar ridge of restricted mesiodistal interdental span who received NDIs. The alveolar ridge width was determined by the ridge mapping technique. Implant stability was measured using Periotest® M immediately after implant insertion then after 4 weeks, 8 weeks and 12 weeks postoperatively. The outcome variables were success rate and implant stability changes during the healing period. The statistical analysis included one-way analysis of variance (ANOVA) and Tukey\'s multiple comparisons test, values < 0.05 w

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Engineering
Evaluation the Effect of Vibration on the Corrosion Rate of Automotive Paints
...Show More Authors

This paper studies the influence of temperature on the corrosion rate of coated AA6111 aluminum alloy used in vehicle bodies under static and vibration states. The vibration test system was collected laboratory and used for testing of five different types of paints (EASI, Numix, Lesonal, DENSO and Polaron paints) in the 5 % NaCl solution using immersion test method. Lesonal paint provided the best corrosion protection, while DENSO paints show large values of corrosion rate, other coatings exhibit moderate values. Model of paints corrosion was developed to characterize the corrosion processes occur at the surfaces. It is found that corrosion rate obtained at vibration cases is larger than static cases and vibration effect

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Aug 28 2021
Journal Name
Journal Of Pharmaceutical Research International
Effect of Formulation Parameter on Dissolution Rate of Flurbiprofen Using Liquisolid Compact
...Show More Authors

Attempts were made to improve solubility and the liquisolid technology dissolving of medication flurbiprofen. Liquisolid pill was developed utilizing transcutol-HP, polyethylene glycol 400, Avecil PH 102 carrier material and Aerosil 200 layer coating material. Suitable excipient amounts were determined to produce liquisolid powder using a mathematical model. On the other hand, flurbiprofen tablet with the identical composition, directly compressed, was manufactured for comparison without the addition of any unvolatile solvent. Both powder combination characterizations and after-compression tablets were evaluated. The pure drug and physical combination, and chosen liquisolid tablets were studied in order to exclude interacting with t

... Show More
View Publication Preview PDF
Crossref (3)
Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
دراسات قانونية
The Legal Nature of the Build-Operate- transfer-Ownership Contract (B.O.T.)
...Show More Authors

The legal nature of the Build-Operate-Transfer-Ownership Contract (B.O.T) The Build, Operate, and Transfer of Ownership Contract (BOT) has emerged as the most successful and safest method for involving the private sector in public sector services. The major infrastructure projects that are built through the BOT contract are no longer financed by the state and its budget, but the private sector has played a major role in financing These projects, especially developing countries that need to establish infrastructure or modernize their existing infrastructure, especially in the areas of transport, communications, services, electricity, water ..... and other public utilities.

Publication Date
Mon Jun 01 2020
Journal Name
Case Studies In Thermal Engineering
Al2O3-water nanofluid heat transfer enhancement of a twin impingement jet
...Show More Authors

Scopus (22)
Scopus
Publication Date
Sun Jun 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Convective Heat Transfer of Fluid Flowing Across a Vertical Plate
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Jul 21 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Numerical Study of the Heat Transfer Behavior in Helical Microcoil Tube
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Mechanical Engineering Research And Developments
Effect of Circular Turbulators on Heat Transfer in A Square Duct
...Show More Authors

Publication Date
Fri Jul 01 2022
Journal Name
Journal Of Engineering
Conjugate Heat Transfer of Laminar Air Flow in Rectangular Mini Channel
...Show More Authors

Conjugate heat transfer has significant implications on heat transfer characteristics, particularly in thick wall applications and small diameter pipes. In this study, a three-dimensional numerical investigation was carried out using commercial CFD software “ANSYS FLUENT” to study the influence of conjugate heat transfer of laminar flow in mini channels at constant heat flux wall conditions. Two parameters were studied and analyzed: the wall thickness and thermal conductivity and their effect on heat transfer characteristics such as temperature profile and Nusselt number. Thermal conductivity of (0.25, 10, 202, and 387) W/m2C and wall thickness of (1, 5, and 50) mm were used for a channel of (1*2) mm cross

... Show More
View Publication Preview PDF
Scopus Crossref