Background: Laser is a novel physical therapy technique used to treat various conditions, including wound healing, inhibition of bacterial growth, and postoperative wounds. High-power pulsed alexandrite laser therapy is one of the most prevalent forms of laser therapy, which is a noninvasive method for treating various pathological conditions, thereby enhancing functional capacities and quality of life. It is a modern medical and physiotherapeutic technology. Generally, the Alexandrite laser emits infrared light with a wavelength of 755 nm, allowing it to propagate and penetrate tissues. Objective: This study focused on the application of a high-power pulsed alexandrite laser in vitro to evaluate the effect of a pulsed alexandrite laser on antibiotic-resistant bacteria utilizing varying exposure times, pulse durations, and laser fluencies to determine which dose is more effective on S. aureus bacteria. Method: The laser used in this study was the alexandrite laser which was considered a pulsed laser and had the following parameters: The wavelength was 755 nm, the beam diameter was (14 mm), the exposure times varied (30, 60, 90) seconds, the laser fluency (5, 10, 15 and 20 J.Cm-2). The study was carried out after the bacteria were diagnosed as being antibioticresistant. They were exposed to different doses of Alexandrite laser. Three samples of bacteria were exposed to laser beams for 30 seconds with a 5ms pulse duration and with a laser fluency of 5J/cm2, and this process was repeated with laser fluencies of 10, 15, and 20. This procedure was repeated using exposure times of 60sec and 90sec. As well as, this process was repeated by exposure with 30 sec, 60 sec and 90 sec exposure times, 10ms and 20ms pulse durations and with different laser fluencies 5, 10, 15 and 20J/cm2, separately. Results: A significant reduction (p = <0.0001) in the mean values of the colony was observed with the increase of laser fluency doses compared with control at the same pulse duration. A significant reduction (p = <0.0001) in the mean count of the colonies was observed in the comparison between two laser fluences at the same pulse duration. In conclusion, the exposure times, pulse durations and laser fluencies of pulsed alexandrite laser showed an effect on the mean count of the colonies of S aureus bacteria and determined the effective dose. Keywords: laser, Staphylococcus aureus, Bacteria growth
Specimens have been collected from one hundred and seventeen patients residing in local hospitals, 33 with burns and 84 wound injuries,. Three different methods ,Cefoxitin disk diffusion, EPI-M Screening Kit and Crome agar (MeReSa agar)with selective supplement were used to detect methicillin-resistant Staphylococcus aureus (MRSA) . A comparison was made between these 3 methods according to the results. It was found that the results of the Cefoxitin disk diffusion test were compatible with the results of culturing on Crome agar, while those obtained from the EPI-M Screening kit were not accurate and some of them gave false negative results.
The subject of biophysics is interdisciplinary and covers various fields of biology and physics. In this research the effect of some parameters of Nd:YAG laser on ants (Camponotus consobrinus) has been studied . This includes the effect on its external shape, as well as the percentage of the killing rate obtained. A laser radiation of a wavelength (1.064 µm) with different energies: (300, 320, 340, 360, 380 and 480 mJ) was used to irradiate ants placed at a distance of (10 cm) distance from the laser source . The irradiation times were (15 and 20 sec) for each energy. The obtained results showed an increase in the rate of ant mortality, as well
... Show MoreLaser beam has been widely used to improve the mechanical properties of the metals. It used for cutting, drilling, hardening, welding……etc. The use of Laser beam has many features in accuracy and speeding in work, also in the treatment of metals locally, and in the places that is hard to reach by traditional ways. In this research a surface treatment was done to medium carbon steel (0.4%C) which is common kind of steel that is used in industry. Pulsing Neodymium -YAG Laser has been used and 1.06 micrometer wave length and 5 msec and the distance is about 30 centimeter between the exit area of the Laser beam from the system and the piece that treated . We are going to check the fatigue resistance for samples that is
... Show MoreThe study aimed to identify the effect of Total Quality Management on enhancing competitiveness through the opinions of employees of the front- rows of customer service in local Palestinian banks, the researcher adopted an analytical descriptive method through developing a special questionnaire to accomplish the study’s objectives and answer its questions. The study involved all the Palestinian local banks, with their scattered branches in West Bank. The study sample consisted of 3470 executive employees for banking services out of 4753 employees, in the rate of 73%, and the study sample reached (485) employees who were randomly selected working in the front -rows to provide services in the local Palestinian banks during the ye
... Show MoreBackground: to evaluate the effect of different dentifrices on the surface roughness of two composite resins (nanofilled-based and nanoceramic – based composite resins). Materials and methods: Forty specimens (diameter 12 mm and height of 2mm) prepared from different composite resin materials: Z350 (nanofilled composite, and Ceram-X (nanoceramic) .they were subjected to brushing simulation equivalent to the period of 1 year. The groups assessed were a control group brushed with distilled water (G1), Opalescence whitening toothpasteR (G2), Colgate sensitive pro-relief (G3) and Biomed Charcoal Toothpaste (G4). The initial and final roughness of each group was tested by surface roughness tester. The results were statistically analyzed using
... Show MoreThis research foxed on the effect of fire flame of different burning temperatures (300, 400 and 500)oC on the compressive strength of reactive powder concrete (RPC).The steady state duration of the burning test was (60)min. Local consuming material were used to mixed a RPC of compressive strength around (100) MPa. The tested specimens were reinforced by (3.0) cm hooked end steel fiber of (1100) MPa yield strength. Three steel fiber volume fraction were adopted in this study (0, 1.0and 1.5)% and two cooling process were included, gradual and sudden. It was concluding that increasing burning temperature decreases the residual compressive strength for RPC specimens of(0%) steel fiber volume fraction by (12.16, 19.46&24.49) and (18.20, 27.77 &3
... Show More
The nanocompsite of alumina (Al2O3) produced a number of beneficial effects in alloys. There is increasing in resistance of materials to surface related failures , such as the mechanical properties , fatigue and stress corrosion cracking .The experimental results observed that the adding of reinforced nanomaterials type Al2O3 enhanced the HB hardness, UTS, 0.2 YS and ductility of 2014 Al/Al2O3 nano composites . the analysis of experiments, indicated that The maximum enhancement was observed at 0.4 wt.% Al2O3. The ultimate improvement percentage were 15.78% HB hardness, 18.1% (UTS), 12.86% (
... Show MoreThe potential use of bone marrow stromal cells as a cellular therapy for chronic diseases relies on the ability of the cell to replicate extensively in vitro.For this reason the present study investigated the replication lifespan and examined the growth properties of albino rats mesenchymal stem cells(MSCS)in vitro. To establish an in vitro system for isolating and culturing the MSCs of albino rats and to provide research data for its further application,the bone marrow (BM)was collected from young male rats and separated by gradient centrifugation.Then, the mononuclear cells(MNCs) were retrieved from the buffy layer and cultured in Modified Eagle,s Medium (MEM) supplemented with 10%Fetal Calf Serum (FCS)and incubation
... Show More