Background: Laser is a novel physical therapy technique used to treat various conditions, including wound healing, inhibition of bacterial growth, and postoperative wounds. High-power pulsed alexandrite laser therapy is one of the most prevalent forms of laser therapy, which is a noninvasive method for treating various pathological conditions, thereby enhancing functional capacities and quality of life. It is a modern medical and physiotherapeutic technology. Generally, the Alexandrite laser emits infrared light with a wavelength of 755 nm, allowing it to propagate and penetrate tissues. Objective: This study focused on the application of a high-power pulsed alexandrite laser in vitro to evaluate the effect of a pulsed alexandrite laser on antibiotic-resistant bacteria utilizing varying exposure times, pulse durations, and laser fluencies to determine which dose is more effective on S. aureus bacteria. Method: The laser used in this study was the alexandrite laser which was considered a pulsed laser and had the following parameters: The wavelength was 755 nm, the beam diameter was (14 mm), the exposure times varied (30, 60, 90) seconds, the laser fluency (5, 10, 15 and 20 J.Cm-2). The study was carried out after the bacteria were diagnosed as being antibioticresistant. They were exposed to different doses of Alexandrite laser. Three samples of bacteria were exposed to laser beams for 30 seconds with a 5ms pulse duration and with a laser fluency of 5J/cm2, and this process was repeated with laser fluencies of 10, 15, and 20. This procedure was repeated using exposure times of 60sec and 90sec. As well as, this process was repeated by exposure with 30 sec, 60 sec and 90 sec exposure times, 10ms and 20ms pulse durations and with different laser fluencies 5, 10, 15 and 20J/cm2, separately. Results: A significant reduction (p = <0.0001) in the mean values of the colony was observed with the increase of laser fluency doses compared with control at the same pulse duration. A significant reduction (p = <0.0001) in the mean count of the colonies was observed in the comparison between two laser fluences at the same pulse duration. In conclusion, the exposure times, pulse durations and laser fluencies of pulsed alexandrite laser showed an effect on the mean count of the colonies of S aureus bacteria and determined the effective dose. Keywords: laser, Staphylococcus aureus, Bacteria growth
This paper studies the effect of the solar indices (total sunspot no., solar wind density and coronal mass ejection linear speed) on F2- layer electron density, as well as, the comparison of seasonal variations of electron density of F2- layer, NmF2, for Mars at local noontime and for maximum and minimum solar cycles.
Results show that there is an inverse correlation between sunspot number, solar wind density, CME linear speed and ionosphere electron density for Mars, at maximum and minimum solar cycles. This correlation is clear when electron density is at minimum value.
... Show MoreBackground: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randoml
... Show MoreAnew mathematical formula was proposed to describe the behavior of the extinction coefficient as a function of ambient temperature and wavelengths for some of infrared materials. This formula was derived depending on some experimental data of transmittance spectrum versus wavelengths for many ambient temperatures. The extensive study of the spectrum characteristics and depending on Bose-Einstein distribution led to derive an equation connecting the extinction coefficient or the absorption coefficient with the ambient temperature and wavelengths of the incident rays. The basic assumption in deriving process is the decreasing in transmittance value with the increasing temperature which is only due to the changing in extinction coeffi
... Show MoreBackground: - Aspergillus fumigatus is a ubiquitous and opportunistic fungal pathogen causing sever invasive aspergillosis, an important source of morbidity and mortality in
immunocompromised hosts (human and animals) .The present study was conducted to obtain more clarification about the toxicity and histopathological effects of this pathogen in albino mice
Material and Methods :- fourteen male mice( 6-10) weeks old ,( 20 – 28) gm weight , divided into two groups , test group ( n= 8) , intranasally infected with 25μl (710 conidia / ml normal
saline ) of A. fumigatus for 7 successive days , compared with uninfected group ( n=6) . the weight of all animals were measured at the beginning and at the end of th
The corrosion inhibition of low carbon steel in1N HCl solution in the presence of peach juice at temperature (30,40,50,and 60)°C at concentration ( 5, 10, 20, 30, 40and 50 cm3/L)were studied using weight loss and polarization techniques. Results show that the inhibition efficiency was increased with the increase of inhibitor concentration and increased with the increase of temperature up to 50ºC ,above 50ºC (i.e. at 60 ºC) the values of efficiency decreases. Activation parameters of the corrosion process such as activation energies, Ea, activation enthalpies, ΔH, and activation entropies, ΔS, were calculated. The adsorption of inhibitor follows Langmuir isotherm. Maximum inhibition efficiency obtained was a bout 91% at 50ºC in the
... Show MoreThe parametric programming considered as type of sensitivity analysis. In this research concerning to study the effect of the variations on linear programming model (objective function coefficients and right hand side) on the optimal solution. To determine the parameter (θ) value (-5≤ θ ≤5).Whereas the result، the objective function equal zero and the decision variables are non basic، when the parameter (θ = -5).The objective function value increases when the parameter (θ= 5) and the decision variables are basic، with the except of X24, X34.Whenever the parameter value increase, the objectiv
... Show MoreIt is found that hypersensitive teeth have a larger number and wider patent tubules than those of non-sensitive teeth. Objective: The aim of this study is to compare between the effects of diode laser at different power densities, with and without sodium fluoride on the sealing of exposed dentinal tubules and dentin permeability. Materials and methods: 118 teeth were used. Samples were divided into three major groups. The first consisted of 100 teeth used for permeability test. The second consisted of 16 teeth for measuring external surface temperature elevation while irradiation. The third, in turn, consisted of one pair of teeth observed under SEM for dentine surface morphology analysis. Results: For dentin permeability measurement, th
... Show MoreThe aim of this research is to measure and analyze the gap between the actual reality and the requirements of the environmental management system in the middle refineries company/refinery cycle according to ISO14001: 2015, as well as to measure the availability of a clean production strategy and test the relationship and impact between the availability of the requirements of the standard and a clean production strategy for the actual reality in the company.
The research problem was determined by the extent to which the requirements of the environmental management system are applied according to ISO14001: 2015 in the middle refineries company? To what extent are the required clean production strategies ava
... Show MoreThis work has been done with using of epoxy resin mixed with Granite powder were weighted by percent volume (5,10,15, and 20)%and then mixed with epoxy polymer to compose polymer composite. Hand lay-up technique is used in fabrication of the composite samples. Hardness test was carried out for the proper samples in both normal condition and after immersion in HCL (1 M and 2 M) solutions for periods ranging up to 10 weeks. After comparing the results between the polymer and their composite, the hardness increased with increasing Granite weight percent, it was found that Hardness were greater for the composites before immersion compared with their values after immersion.