Preferred Language
Articles
/
NBc2oZIBVTCNdQwCBbvg
Recent advances in polymeric implants
...Show More Authors

Implantable drug delivery systems, such as drug pumps and polymeric drug depots, have emerged as means of providing predetermined drug release profiles at the desired site of action. While initial implants aimed at providing an enduring drug supply, developments in polymer chemistry and pharmaceutical technology and the growing need for refined drug delivery patterns have prompted the design of sophisticated drug delivery implants such as on-demand drug-eluting implants and personalized 3D printed implants. The types of cargo loaded into these implants range from small drug molecules to hormones and even therapeutic cells. This review will shed light upon recent advances in materials and composites used for polymeric implant fabrication, highlight select approaches employed in polymeric implant fabrication, feature medical applications where polymeric implants have a significant impact, and report recent advances made in these areas.

View Publication
Publication Date
Sat Mar 03 2018
Journal Name
International Journal Of Science And Research
In Vivo Mechanical and Histological Evaluation of the Effect of Vacuum Storage and Ultra Violet Light Treatment of Titanium Implants on Osseointegration
...Show More Authors

Background: Titanium implant is widely used in dentistry because of its extraordinary biocompatibility and mechanical properties. To increase bone–implant connection and provide early loading after placement, implant is stored in different storage medium and treated with UV light. Both of them are applicable methods to increase the bioactivity of titanium and overcome the biological aging. This study was designed to assess the effect of vacuum storage method and air storage with and without UV light treated of Cp Ti implant mechanically and histologically. Materials and methods: Titanium screws were acid etched and prepared in four different modes using different storage methods (air or vacuum and, with or without UV treatment. The implan

... Show More
Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Clinical And Experimental Dentistry
Comparison of the accuracy of intraoral digital impression system and conventional impression techniques for multiple implants in the full-arch edentulous mandible
...Show More Authors

View Publication
Scopus (10)
Crossref (13)
Scopus Crossref
Publication Date
Fri Jul 27 2012
Journal Name
Journal Of Prosthodontics
A Three-Dimensional Finite Element Analysis for Overdenture Attachments Supported by Teeth and/or Mini Dental Implants
...Show More Authors

View Publication
Crossref (15)
Crossref
Publication Date
Mon Dec 16 2024
Journal Name
Polimery
Synthesis and photochemical stability of polymeric derivatives formed by the reaction of acrylamide and succinic anhydride copolymer with dyes
...Show More Authors

A new derivative of PAM, acrylamide was copolymerized with succinic anhydride, and the reaction product reacted with three dyes, anthocyanin, bromophenol, and thymol. The prepared polymers were characterized by X-ray diffraction, FT-IR and UV-visible spectroscopy, proton nuclear magnetic resonance spectrometry, and thermal analysis. FT-IR spectroscopy showed the disappearance of two bands near 3450 and 3380 cm-1 for the stretching vibrations of the primary amine which indicates for the formation of amides. The UV-photolysis of aqueous solutions of different concentrations of the polymers was studied. Polyacrylamide-g-succinic anhydride showed an increase in polymerization under light. An increase of ~ 50% was observed for a 200 mg/L

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sat Mar 02 2019
Journal Name
Biochem. Cell.arch.
EVALUATION OF PRIMARY IMPLANTS STABILITY IN IMMEDIATE AND DELAYED TREATMENT PROTOCOLS ACCORDING TO BONE DENSITY, JAWS, GENDER AND AGE UTILIZING PERIOTEST M DEVICE
...Show More Authors

Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Mechanical Evaluation of Pure Titanium Dental Implants Coated with a Mixture of Nano Titanium Oxide and Nano Hydroxyapatite
...Show More Authors

Background: The type of dental implant surface is one of many factors that determine the success of implant restoration. This study aimed to study the effect of mixture of nano titanium oxide with nanohydroxyapatite coating of screw shaped CPTi dental implant on bond strength at bone implant interface by torque removal test related to two healing periods (2 and 6 weeks). Materials and methods: Dip coating process was performed to get an even coating layer on CPTi screws. X-ray diffraction (XRD) analysis and microscopical examination were performed on the coating surfaces of the CPTi. The tibia of 10 white New Zealand rabbits was chosen as implantation sites. The tibia of each rabbit received two screws, one was coated with mixture of nanoT

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Feb 27 2013
Journal Name
Asean Journal For Science And Engineering In Materials
ASTM F75 Alloys: A Systematic Review of Microstructural Characteristics and Manufacturing Advances from Conventional to Laser-Based Techniques with Bibliometric Analysis
...Show More Authors

This study provides a systematic and bibliometric review of ASTM F75 cobalt–chromium alloys, focusing on microstructure and the shift from conventional to laser-based manufacturing. Using combined analytical methods, it evaluates microstructure, mechanical properties, corrosion behavior, and biocompatibility. Results show that laser-based techniques such as LPBF and DMLS produce finer grain sizes (1–10 µm vs. 50–200 µm), leading to improved hardness (20–40%) and tensile strength (15–30%). Despite challenges like residual stress and process optimization, these methods show strong potential for high-performance and sustainable applications.

View Publication Preview PDF
Scopus
Publication Date
Mon Apr 06 2020
Journal Name
Bmc Oral Health
The reliability of surgeons to avoid traumatic insertion of dental implants into high-risk regions: a panoramic radiograph study
...Show More Authors
Abstract<sec><title>Background

The posterior regions of the jaws usually represent a significant risk for implant surgery. A non-valid assessment of the available bone height may lead to either perforation of the maxillary sinus floor or encroachment of the inferior alveolar nerve and consequently to implant failure. This study aimed to evaluate the reliability of surgeon’s decision in appraising the appropriate implant length, in respect to vital anatomical structures, using panoramic radiographs.

Methods

Only implants that are inserted in relation to the maxillary sinus (MS) or the mandibular canal (MC) were enrolled (firs

... Show More
View Publication
Scopus (11)
Crossref (7)
Scopus Crossref
Publication Date
Sun Nov 01 2020
Journal Name
The International Journal Of Oral &amp; Maxillofacial Implants
Early Failure Rate and Associated Risk Factors for Dental Implants Placed With and Without Maxillary Sinus Augmentation: A Retrospective Study
...Show More Authors

View Publication
Scopus (28)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (18)
Crossref (21)
Scopus Clarivate Crossref