Preferred Language
Articles
/
NBZSxocBVTCNdQwCXWEl
H-Point Standard Addition Method for Simultaneous Determination of Cimetidine and Erythromycin Ethylsuccinate Drugs Using Bromothymol Blue as a Chromogenic Complexing Agent
...Show More Authors

The H-Point Standard Addition Method (H-PSAM) has been applied for spectrophotometric simultaneous determination of Cimetidine and Erythromycin ethylsuccinate using Bromothymol Blue (BTB) as a chromogenic complexing agent in a buffer solution at pH 5.5.

Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Dithiocarbamates derivatives as anticancer agents: A Review
...Show More Authors

View Publication
Crossref (10)
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
The Journal Of Continuing Education In Nursing
Debate as a Teaching Strategy in Nursing
...Show More Authors

Debate is a teaching strategy in nursing education that enhances students' critical thinking. Although debate can be an effective teaching strategy, it is not without limitations. This article discusses the advantages and disadvantages of debate as a teaching strategy in nursing. Also, evaluating debates and choosing topics are highlighted. [ J Contin Educ Nurs . 2021;52(6):263–265.]

View Publication
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
View Publication Preview PDF
Scopus (26)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
Scopus (26)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Inorganic Chemistry Communications
Sarin chemical warfare agent detection by Sc-decorated XN nanotubes (X = Al or Ga)
...Show More Authors

In order to scrutinize the impact of the decoration of Sc upon the sensing performance of an XN nanotube (X = Al or Ga, and XNNT) in detecting sarin (SN), the density functionals M06-2X, τ-HCTHhyb, and B3LYP were utilized. The interaction of the pristine XNNT with SN was a physical adsorption with the sensing response (SR) of approximately 5.4. Decoration of the Sc metal into the surface of the AlN and GaN led to an increase in the adsorption energy of SN from −3.4 to −18.9, and −3.8 to −20.1 kcal/mol, respectively. Also, there was a significant increase in the corresponding SR to 38.0 and 100.5, the sensitivity of metal decorated XNNT (metal@XNNT) is increased. So, we found that Sc-decorating more increases the sensitivity of GaNN

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Jun 22 2020
Journal Name
Baghdad Science Journal
Phase Fitted And Amplification Fitted Of Runge-Kutta-Fehlberg Method Of Order 4(5) For Solving Oscillatory Problems
...Show More Authors

In this paper, the proposed phase fitted and amplification fitted of the Runge-Kutta-Fehlberg method were derived on the basis of existing method of 4(5) order to solve ordinary differential equations with oscillatory solutions. The recent method has null phase-lag and zero dissipation properties. The phase-lag or dispersion error is the angle between the real solution and the approximate solution. While the dissipation is the distance of the numerical solution from the basic periodic solution. Many of problems are tested over a long interval, and the numerical results have shown that the present method is more precise than the 4(5) Runge-Kutta-Fehlberg method.

View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Link Failure Recovery for a Large-Scale Video Surveillance System using a Software-Defined Network
...Show More Authors

The software-defined network (SDN) is a new technology that separates the control plane from data ‎plane for the network devices. One of the most significant issues in the video ‎surveillance system is the link failure. When the path failure occurs, the monitoring center cannot receive the ‎video from the cameras. In this paper, two methods are proposed to solve this problem.  The first ‎method uses the Dijkstra algorithm to re-find the path at the source node switch. The second method ‎uses the Dijkstra algorithm to re-find the path at the ingress node switch (or failed link).

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Apr 29 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Cyclic Fatigue Resistance of Wave One Gold, F6 SkyTaper, One Curve, and AF Blue R3 NiTi Rotary Instrumentation Systems
...Show More Authors

Objective: This in vitro study is aimed to compare and evaluate the cyclic fatigue of four varying NiTi rotary instrumentation systems. Method: In this study, four types of rotary files were used in four groups (10 files for each group), namely, Group A: Wave One Gold; Group B: AF Blue R3; Group C: One Curve; Group D: F6 SkyTaper. These groups were evaluated by a cyclic fatigue apparatus to measure cyclic fatigue resistance within the artificial metallic simulating canal that has a 60 angle of curvature, the curvature radius was 5 mm, whereas the inner diameter of the canal was 1.5 mm. All the files were rotated in artificial canals until they fracture. The resistance to cyclic fatigue was determined by counting the number of cycles to frac

... Show More
Scopus (1)
Scopus
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Spectrophotometrically Analysis of PMMA as a low – Doses Dosimeter
...Show More Authors

Polymethylmethacrylate film (PMMA) of thickness 75 μm was evaluated Spectrophotometrically for using it as a low-doses gamma radiation dosimeter. The doses were examined in the range 0.1 mrad-10 krad. Within an absorption band of 200-400 nm, the irradiated films showed an increase in the absorption intensity with increasing the absorbed doses. Calibration curves for the changes in the absorption differences were obtained at 218, 301, and 343 nm. At 218 nm the response for the absorbed doses is a linear in the range 10 mrad- 10 krad. Hence it is recommended to be adopted as an environmental low doses dosimeter

View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Water Pollution And Management Practices
Existence of Antibiotics in Wastewater as a Pollution Indicator
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Crossref