Introduction: Methadone hydrochloride (MDN) is an effective pharmacological substitution treatment for opioids dependence, adopted in different countries as methadone maintenance treatment (MMT) programmes. However, MDN can exacerbate the addiction problem if it is abused and injected intravenously, and the frequent visits to the MMT centres can reduce patient compliance. The overall aim of this study is to develop a novel extended-release capsule of MDN using the sol-gel silica (SGS) technique that has the potential to counteract medication-tampering techniques and associated health risks and reduce the frequent visits to MMT centres. Methods: For MDN recrystallisation, a closed container method (CCM) and hot-stage method (HSM) were conducted, and MDN crystals were characterised using the polarised light microscope (PLM). MDN crystal thickness was determined by scanning electron microscopy (SEM) and confocal microscopy (CM) to establish a relationship between MDN crystals thickness and their birefringence colours using the Michel-Levy Birefringence Colour Chart. The experimental series was continued to produce novel silica-based MDN formulations A and B capsules by adding MDN powder at the end and beginning of the SGS process, respectively. The silica-based MDN formulations were characterised by Fourier transform infrared (FT-IR), SEM, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), PLM and mean grey value (MGV) analyses. The in vitro release studies (n=3) for the silica-based MDN formulations and pure MDN capsules were conducted in a phosphate buffer solution (pH= 7.2) for 7 days. Stability studies were conducted for 1 month by keeping the silica-based MDN capsules under 25°C and 57% RH. Results: The optimal method to produce large numbers of MDN crystals was the CCM, and MDN crystals were characterised as diamond shaped with an intrinsic angle of 62o. The SEM surpassed the CM in measuring MDN crystal thickness, and Mann-Whitney U Test showed statistically significant differences between SEM and confocal thickness measurements (U= 1283, p < 0.05) as the SEM exhibited thinner diamond crystals (6.62 ± 2.9 µm) than the CM measurements (9.6 ± 4.6µm). According to the Michel-Levey birefringence colour chart (using the SEM mean thickness of MDN crystals and their retardation value of 428 nm), most of MDN crystals demonstrated a yellow colour. The FT-IR, SEM, DSC, MGV and PLM analyses of both silica-based MDN formulations revealed that MDN was successfully incorporated inside the silica network producing amorphous material (with no appearance of the melting peak of pure MDN at 233.4°C) with evidence of no physical or chemical interaction between sol-gel silica and MDN. However, the TGA analysis revealed a significantly greater amount of MDN was loaded inside the silica-based MDN formulation B compared to A (t = 2.80, p = 0.009, n=6), as 28.3 ± 0.6 mg of MDN was loaded in the former while 25.6 ± 0.7 mg in the latter. In addition, the silica-based MDN formulation B released 10% more MDN after 7 days than formulation A, and both formulations were stable when stored for 1 month under 57% RH and 25°C. Conclusion: The novel combined use of SEM and PLM techniques shows a potential for the identification of MDN in forensic science as it established a range of birefringence colours of MDN crystals. Moreover, the new silica-based MDN formulation B can help to deter MDN abuse and increase patient adherence to MMT due to its potential to sustain MDN release and reduce the frequent visits to MDN treatment centres.
Introduction The Hybrid Gamma Camera (HGC) is being developed to enhance the localisation of radiopharmaceutical uptake in targeted tissues during surgical procedures such as sentinel lymph node (SLN) biopsy. Purpose To assess the capability of the HGC, a lymph-node-contrast (LNC) phantom was constructed for an evaluative study simulating medical scenarios of varying radioactivity concentration and SLN size. Materials and methods The phantom was constructed using two methyl methacrylate PMMA plates (8 mm thick). The SLNs were simulated by drilling circular wells of diameters ranging between 10 mm and 2.5 mm (16 wells in total) in one plate. These simulated SLNs were placed underneath scattering material with thicknesses ranging between 5 mm
... Show MoreIn this work, of New Ligand [(E)-5-hydroxy-4-(3-(4-methoxy phenyl) acryl amido) naphthalene -1- sulfonic acid] (ANS) was prepared by reflexing reaction of 4-amino-5-hydroxy naphthalene sulfonic acid with para methoxy cinnamic acid, this produced and described chemical was employed as ligand to prepare tri and di-organotin complexes by condensation reaction with the salts of organotin chloride (phenyl, butyl, and methyl tin chloride). Specialized methods, including elemental analysis, (tin and proton) magnetic resonance, and infrared spectra, were used to identify the complexes. DPPH (2,2-diphenyl-1-picrylhydrazyl) and CUPRAC (Cupric Reducing Antioxidant Capacity) are both commonly used methods for measuring antioxidant capacity in v
... Show MoreDevelopment of a precise and delicate reaction has been acquired for the determination of vancomycin hydrochloride using batch and cloud point extraction (CPE) methods. The first method is based on the formation of azo dye as a result of diazotized dapsone coupled with vancomycin HCl (VAN) in a basic medium. The sensitivity of this reaction was enhanced by utilizing a nonionic surfactant (Triton X-114) and the cloud point extraction technique (second method). The azo dye formed was extracted into the surfactant-rich phase, dissolved in ethanol and detected at λmax 440 nm spectrophotometrically. The reaction was investigated using both batch and CPE methods (with and without extraction), and a simple comparison between the two
... Show MoreA simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show MoreThe reason for conducting this study is to prolong release of miconazole in the ocular site of action by ocular-based gels (OBGs) formulations. The formulation factors affecting on the release from OBG should be studied using various gelling agents in various concentrations to achieve the improvement in retention and residence time in response to prolonged release. In this study, the formulations were prepared using carbopol 940, pectin, sodium alginate, poloxamer 407, and poly(methacrylic acid) at 0.5%, 1%, and 1.5% w/v, respectively. Hydroxypropyl methylcellulose E5 (HPMC E5) 1% was added as thickening agent/viscosity builder. The formulation containing carbopol 940, pectin and sodium alginate at 1.5% w/v, displayed a noticable im
... Show MoreObjective: The aim of this study was to formulate and in vitro evaluate fast dissolving oral film of practically insoluble bromocriptine mesylate to enhance its solubility and to improve its oral bioavailability by avoiding first pass effect as well as to produce an immediate release action of the drug from the film for an efficient management of diabetes mellitus type II in addition to an improvement of the patient compliance to this patient- friendly dosage form. Methods: The films were prepared by the solvent casting method using hydroxypropyl methylcellulose of grades (E3, E5, E15), polyvinyl alcohol (PVA), pectin and gelatin as film-forming polymers in addition to polyethene glycol 400 (PEG400), propylene glycol (PG) and glycerin were
... Show More