Preferred Language
Articles
/
MhYcU4cBVTCNdQwCfUU6
The reliability of surgeons to avoid traumatic insertion of dental implants into high-risk regions: a panoramic radiograph study
...Show More Authors
Abstract<sec> <title>Background

The posterior regions of the jaws usually represent a significant risk for implant surgery. A non-valid assessment of the available bone height may lead to either perforation of the maxillary sinus floor or encroachment of the inferior alveolar nerve and consequently to implant failure. This study aimed to evaluate the reliability of surgeon’s decision in appraising the appropriate implant length, in respect to vital anatomical structures, using panoramic radiographs.

Methods

Only implants that are inserted in relation to the maxillary sinus (MS) or the mandibular canal (MC) were enrolled (first premolars [1P], second premolars [2P], first molars [1M], and second molars [2M]). All preoperative panoramic radiographs were evaluated under standard conditions. The postoperative estimation (under/over) was determined depending on the available bone height (ABH) measured from the apical end of the implant to the floor of the MS and the roof of the MC using cone beam computed tomography (CBCT). Any complication or side effect that associated with overestimated implants insertion was recorded.

Results

The study sample included 73 patients (predominantly females) who had consecutively received 148 implants, of which 68 were inserted in the posterior maxilla and 80 in the posterior mandible. Underestimation was recorded in 93.2% of the measurements. The remaining bone height after implants insertion was < 2 mm in the majority of underestimated cases (73.9%); they were significantly (P < 0.01) more than sites with remaining bone ≥ 2 mm (26.1%). In the posterior mandible, overestimation was significantly higher than posterior maxilla. Five cases with transient paresthesia were reported in the mandibular overestimated implants.

Conclusions

This study specified that surgeon’s choice of implants length, based on panoramic radiographs, was reliable regarding the incapability to insert implants with further length in the majority of underestimated cases, the low percent of overestimated measurements, and the minor associated complications.

Crossref
View Publication
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
RELIABILITY ANALYSIS OF THE SEISMIC STABILITY OF EMBANKMENTS REINFORCED WITH STONE COLUMNS
...Show More Authors

Geotechnical engineers have always been concerned with the stabilization of slopes. For this purpose,
various methods such as retaining walls, piles, and geosynthetics may be used to increase the safety factor of slopes prone to failure. The application of stone columns may also be another potential alternative for slope stabilization. Such columns have normally been used for cohesive soil improvement. Most slope analysis and design is based on deterministic approach i.e a set of single valued design parameter are adopted and a set of single valued factor of safety (FOS) is determined. Usually the FOS is selected in view of the understanding and knowledge of the material parameters, the problem geometry, the method of analysis and the

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Sep 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Risk Assessment Due to Population Exposure to Lead Particles Emitted from Domestic Electrical Generators
...Show More Authors

Portable and stationary electrical generators became quite popular in Iraq soon after the shortage in national electrical
energy after 2003. Multi step risk assessment process is used in this study in the assessment of risks caused by
contamination of indoor air by lead particles emitted from domestic electrical generators. Two portable electrical
generators are tested under controlled indoor conditions (Radial LG (0.9 keV) fueled with benzene and oil and TigMax
(3 keV), fueled with benzene only). Lead particles in air were sampled by using portable dust sampler (Sniffer, L-30).
The atmospheric particulate sampling process is carried out in a flat located in the first floor of a three stories building
located in Baghdad

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 31 2019
Journal Name
Journal Of Engineering
A High Resolution 3D Geomodel for Giant Carbonate Reservoir- A Field Case Study from an Iraqi Oil Field
...Show More Authors

Constructing a fine 3D geomodel for complex giant reservoir is a crucial task for hydrocarbon volume assessment and guiding for optimal development. The case under study is Mishrif reservoir of Halfaya oil field, which is an Iraqi giant carbonate reservoir. Mishrif mainly consists of limestone rocks which belong to Late Cenomanian age. The average gross thickness of formation is about 400m. In this paper, a high-resolution 3D geological model has been built using Petrel software that can be utilized as input for dynamic simulation. The model is constructed based on geological, geophysical, pertophysical and engineering data from about 60 available wells to characterize the structural, stratigraphic, and properties distribution along

... Show More
Crossref (1)
Crossref
Publication Date
Tue Dec 31 2019
Journal Name
Journal Of Engineering
A High Resolution 3D Geomodel for Giant Carbonate Reservoir- A Field Case Study from an Iraqi Oil Field
...Show More Authors

Constructing a fine 3D geomodel for complex giant reservoir is a crucial task for hydrocarbon volume assessment and guiding for optimal development. The case under study is Mishrif reservoir of Halfaya oil field, which is an Iraqi giant carbonate reservoir. Mishrif mainly consists of limestone rocks which belong to Late Cenomanian age. The average gross thickness of formation is about 400m. In this paper, a high-resolution 3D geological model has been built using Petrel software that can be utilized as input for dynamic simulation. The model is constructed based on geological, geophysical, pertophysical and engineering data from about 60 available wells to characterize the structural, stratigraphic, and properties distri

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Nov 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of dental arches symmetry in a sample of Iraqi children at the mixed dentition stage
...Show More Authors

Background: Little is known about asymmetry of children's dental arches, the purpose of this study was to verify the presence of asymmetry of dental arches among Iraqi children in the mixed dentition stage. Materials and methods: The sample included 52 pairs of dental casts, 27 pairs belong to males and 25 pairs for females. Three linear distances were utilized on each side on the dental arch: Incisal-canine distance, canine-molar distance and incisal-molar distance, which represent the dental arch segmental measurements using the digital sliding calipers, which is accurate up to 0.02 mm. Results: No significant sides' differences with high correlation coefficient were found between the right and left incisal-canine, canine-molar and in

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Crystal Growth of High – Purity Bi2Se3 and Study of Crystal Structure
...Show More Authors

The Bi2Se3 compound was synthesis by fusing initial compounds consisting of
extra pure elements in stoichiometric ratio from elements compound, charged inside
quartz ampoule. The crystal growth of Bi2Se3 carried out using Brighaman technique
process from melting f (Bi+Se ) at temperature of 810 ºC for about 48 hrs. Single crystal
of Bi2Se3 has been grown in direction (211) after slow cooling on account of heat
gradient to zone furnaces at cooling rate (1-3) C/hr. The structure study of the compound
was determined by x-ray diffraction technique, which it has bismuthinite structure and
orthorhombic unit cell with lattice parameters of a=10.2678 Å, b=11.2392 Å and
c=5.1737 Å

View Publication Preview PDF
Publication Date
Tue Nov 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the anterior loop of the mental nerve incidence and extension in different age groups in Sulaimania city using digital panoramic imaging system
...Show More Authors

Background: The anterior loop of mental nerve is commonly described as that part of the neurovascular bundle that transverses anterior and inferior to the mental foramen only to loop back to exit the mental foramen. The aim of the study is to evaluate the incidence and extension of anterior loop of mental nerve by using digital panoramic imaging system to avoid nerve damage during different surgical procedures in dentistry. Materials and Method: Panoramic image was taken for all 400 patients and stored in the computer. Then Horizontal and Vertical for the anterior loop extension when exist was measured and recorded in a special case sheet prepared for each subject. Results: Results indicated that out of 400 patients there were only 25 pat

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Clinical Dentistry Preview Publication Details
The effect of surgical approaches on the stability and marginal bone loss of early loaded slactive implants with screw retention mean: Comparative clinical and radiological prospective study
...Show More Authors

Purpose: This study aimed to compare the stability and marginal bone loss of implants inserted with flapped and flapless approaches 8 weeks after surgery and 3 months after loading. Material and Methods: Thirty SLActive implants were inserted in 11 patients and early loaded with final restoration 8 weeks after healing period. The stability values determined by Osstell and the marginal bone loss measured by CBCT at the initial time (1st) and 8 weeks of the healing period (2nd) and 3 months after loading (3rd). Results: The overall survival rate was 100%. A significant increase in the 3rd implant stability value in the age of ˂ 40. A significant decrease in the 2nd implant stability value in both gender and traumatic zone with a flapless app

... Show More
View Publication Preview PDF
Scopus
Publication Date
Tue Nov 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Biomechanical evaluation of porous titanium implants (CpTi) fabricated by powder technology
...Show More Authors

Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um part

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 31 2020
Journal Name
Bmc Oral Health
The success of using 2% lidocaine in pain removal during extraction of mandibular premolars: a prospective clinical study
...Show More Authors
Abstract<sec><title>Background

The purpose of this study was to evaluate the anesthetic effectiveness of a buccal infiltration technique combined with local massage (using 2% lidocaine) in the extraction of mandibular premolars to be utilized as an alternative to the conventional inferior alveolar nerve block.

Methods

Patients eligible included any subject with a clinical indication for tooth extraction of the mandibular 1st or 2nd premolars. All patients were anesthetized buccally by local infiltration technique followed by an external pressure applied for 1 min directly over the injection area. In each case, another local

... Show More
View Publication
Crossref (8)
Crossref