Carbon dioxide geo-sequestration (CGS) into sediments in the form of (gas) hydrates is one proposed method for reducing anthropogenic carbon dioxide emissions to the atmosphere and, thus reducing global warming and climate change. However, there is a serious lack of understanding of how such CO2 hydrate forms and exists in sediments. We thus imaged CO2 hydrate distribution in sandstone, and investigated the hydrate morphology and cluster characteristics via x-ray micro-computed tomography in 3D in-situ. A substantial amount of gas hydrate (∼17% saturation) was observed, and the stochastically distributed hydrate clusters followed power-law relations with respect to their size distributions and surface area-volume relationships. The layer-like hydrate configuration is expected to reduce CO2 mobility in the reservoir, and the smaller than expected hydrate surface-area/volume ratio will reduce methane production and CO2 storage capacities. These findings will aid large-scale implementation of industrial CGS projects via the hydrate route.
In this paper we proposed the method of X-ray fluorescence (XRF) determination of some essential trace elements in medicinal herbs and vitamin-mineral complexes at the level of 100-101 mg/ml. To increase sensitivity and selectivity of the determination we simple and effective approach based on the extraction of metal ions from aqueous solutions with chemically modified polyurethane foam sorbents followed by direct XRF analysis. The conditions of sorption preconcentration of Co(II), Ni(II) and Zn(II) ions with modified sorbents were optimized. The proposed approach is used for the determination of trace elements in several kinds of medicinal herbs (coltsfoot leaves, nettle leaves and yarrow herb) and vitamin-mineral
... Show MoreA lotic ecosystem is considered a source of carbon dioxide (CO2) in the atmosphere where it becomes supersaturated with CO2, which contributes to the global carbon cycle. To enhance our comprehension of the roles of CO2 in rivers, an outdoor experiment was designed with controlled carbon source inputs to investigate the roles of the dissolved organic carbon (DOC) and dissolved inorganic carbon (DIC) in the phytoplankton community. Plastic enclosures were installed in the Tigris River within Baghdad for that goal. Samples were collected on the first day, as well as on the 5th and the 12th days from 14 enclosures. The enclosures were treated by artificial glucose (C6H12O6) (10, 20, 30mg/ l) as DOC sources, while sodium bicarbonate (NaHCO3) (1
... Show MoreAbstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,
... Show MoreIn the present work the clathrate hydrate dissociation enthalpies of refrigerant R134a+ water system, and R134a + water + salt system were determined. The heat of dissociation of three types of aqueous salts solutions of NaCl, KBr and NaF at three concentrations (0.09, 0.17and 0.26) mol·kg−1 for each salt type, were enthalpy measured. The Clapeyron equation was used tocalculate heat of dissociation of experimental data for binary and ternary system.In order to find the effect of compressibility factor on heat dissociation enthalpy, the study was conducted by using equation of state proposed by Peng and Robinson Stryjek-Vera (PRSV). The obtained results of dissociation enthalpy for binary system were (143.8) kJ.mol-1
... Show MoreIn this paper, we investigate the behavior of the bayes estimators, for the scale parameter of the Gompertz distribution under two different loss functions such as, the squared error loss function, the exponential loss function (proposed), based different double prior distributions represented as erlang with inverse levy prior, erlang with non-informative prior, inverse levy with non-informative prior and erlang with chi-square prior.
The simulation method was fulfilled to obtain the results, including the estimated values and the mean square error (MSE) for the scale parameter of the Gompertz distribution, for different cases for the scale parameter of the Gompertz distr
... Show MoreBackground: Maxillary canines are important aesthetically and functionally, but impacted canines are more difficult and time consuming to treat, the aim of this study is to investigate with multi-detector computed tomography the correlation between the bone density and the upper canine impaction. Material and method: A sample of Unilaterally impacted maxillary canines from 24 patients (19 female, 5 male) who were referred to accurately localize the impacted canines at al- Karkh general hospital were evaluated by a volumetric 3-d images by the multi-detector computed tomography to accurately measure the bone density of the maxillary cortical palate of the maxillary impacted canine side and compare it with the other side of the normally erupt
... Show MoreThis thesis was aimed to study gas hydrates in terms of their equilibrium conditions in bulk and their effects on sedimentary rocks. The hydrate equilibrium measurements for different gas mixtures containing CH4, CO2 and N2 were determined experimentally using the PVT sapphire cell equipment. We imaged CO2 hydrate distribution in sandstone, and investigated the hydrate morphology and cluster characteristics via μCT. Moreover, the effect of hydrate formation on the P-wave velocities of sandstone was investigated experimentally.
Abstract: Thorough assessment of the Maxillary,Sinus is very important. Recently 3-dimensional imagewith Cone Beam Computed Tomography (CBCT) is very dependable in Maxillary Sinus diagnosis. The aim of this study is to: shade light on the role of (CBCT) diagnosis of the maxillary sinus anatomical variation and pathological finding among smokers and nonsmokers prior to maxillary sinus lift techniques. Materials and Method: In this study 60 males with age ranged between 20-50 years old, referred for (CBCT) assessment of maxillary sinus in the Specialist Health Center of AL-Sadder city. The scanning were performed using Kodak 9500 (CBCT), the KV was 90, mA10 and scanning time 10 s. Voxel size 0.3mm with( DICOM ) software on a multiplaner re
... Show More