The challenge to incorporate usability evaluation values and practices into agile development process is not only persisting but also systemic. Notable contributions of researchers have attempted to isolate and close the gaps between both fields, with the aim of developing usable software. Due to the current absence of a reference model that specifies where and how usability activities need to be considered in the agile development process. This paper proposes a model for identifying appropriate usability evaluation methods alongside the agile development process. By using this model, the development team can apply usability evaluations at the right time at the right place to get the necessary feedback from the end-user. Verification of the proposed model was conducted using the focus group method by experts from industry domain.
يتناول هذا البحث دراسة واحدة من المفاهيم المهمة الوافدة الى المجتمع الاسلامي، بعد أن تطور في بيئة غربية وتبنته حركة نسوية متطرفة، تدعو الى مركزية الأنثى والعداء للرجل والأسرة النمطية، إنتقل هذا المصطلح الى المجتمع الإسلامي بعد أن تبنته أجندة عالمية تحاول وباستمرار طمس معالم الفطرة الإنسانية وتغير هوية الشعوب.
Introduction: Breast cancer is a significant global health concern, affecting millions of women worldwide. While advancements in diagnosis and treatment have improved survival rates, the impact of this disease extends beyond physical health. It also significantly influences a woman's lifestyle and overall well-being. Objectives: The current study intends to analyze the lifestyle of breast cancer patients who are receiving therapy or are being followed up at the Oncology Teaching Hospital in Medical City, Baghdad, Iraq. Method: The present study uses a descriptive design with an application of an evaluation approach. A convenience sample of 100 women with breast cancer was selected from the Teaching Oncology Hospital at the Medical C
... Show MoreIn this research the performance of 5G mobile system is evaluated through the Ergodic capacity metric. Today, in any wireless communication system, many parameters have a significant role on system performance. Three main parameters are of concern here; the source power, number of antennas, and transmitter-receiver distance. User equipment’s (UEs) with equal and non-equal powers are used to evaluate the system performance in addition to using different antenna techniques to demonstrate the differences between SISO, MIMO, and massive MIMO. Using two mobile stations (MS) with different distances from the base station (BS), resulted in showing how using massive MIMO system will improve the performance than the standar
... Show MoreThe consensus algorithm is the core mechanism of blockchain and is used to ensure data consistency among blockchain nodes. The PBFT consensus algorithm is widely used in alliance chains because it is resistant to Byzantine errors. However, the present PBFT (Practical Byzantine Fault Tolerance) still has issues with master node selection that is random and complicated communication. The IBFT consensus technique, which is enhanced, is proposed in this study and is based on node trust value and BLS (Boneh-Lynn-Shacham) aggregate signature. In IBFT, multi-level indicators are used to calculate the trust value of each node, and some nodes are selected to take part in network consensus as a result of this calculation. The master node is chosen
... Show MoreIn this research, some robust non-parametric methods were used to estimate the semi-parametric regression model, and then these methods were compared using the MSE comparison criterion, different sample sizes, levels of variance, pollution rates, and three different models were used. These methods are S-LLS S-Estimation -local smoothing, (M-LLS)M- Estimation -local smoothing, (S-NW) S-Estimation-NadaryaWatson Smoothing, and (M-NW) M-Estimation-Nadarya-Watson Smoothing.
The results in the first model proved that the (S-LLS) method was the best in the case of large sample sizes, and small sample sizes showed that the
... Show MoreThe superconductor compound (YBa2Cu2.8Zn0.2O7+δ) is prepared by solid state reaction (SSR), Sol-gel (SG) and laser Pulse deposition (PLD) methods. We used the X-ray diffraction technique, which shows an orthorhombic crystalline system for all the samples, and increase in the high-phase (Y-123) and decrease in low-phase and vary in proportion according to the method of preparation with the emergence of some impurities. The behavior of the samples in terms of electrical resistance and critical temperature was investigated all samples showed superconducting behavior. The properties of the dielectric (real dielectric constant, imaginary dielectric constant, loss tangent, alternating electrical conductivity) were s
... Show MoreThe current research aims to adopt production quality decisions as the most important decisions , because they are accompanied by customer satisfaction through monitoring the quality of drinking water in iraq which reach through the pipeline network associated with water treatment projects of Tigris and Euphrates rivers. One of the indicators of quality control was the drawing of the C-chart by specifying the central line and the upper and lower limit of the control and the diagnosis of whether the production system as a whole within the scope of quality control or not and determine the strength and significance of the correlation between the quantities of water And actual needs for customers , the research has reached a number o
... Show MoreSimple and sensitive kinetic methods are developed for the determination of Paracetamol in pure form and in pharmaceutical preparations. The methods are based on direct reaction (oxidative-coupling reaction) of Paracetamol with o-cresol in the presence of sodium periodate in alkaline medium, to form an intense blue-water-soluble dye that is stable at room temperature, and was followed spectrophotometriclly at λmax= 612 nm. The reaction was studied kinetically by Initial rate and fixed time (at 25 minutes) methods, and the optimization of conditions were fixed. The calibration graphs for drug determination were linear in the concentration ranges (1-7 μg.ml-1) for the initial rate and (1-10 μg.ml-1) for the fixed time methods at 25 min.
... Show More