Preferred Language
Articles
/
MRdaWJMBVTCNdQwCStGN
Study of the Effect of Diabetes Mellitus I on Bone Mineral Density of Upper and Lower Limbs by Dual-Energy X-Ray Absorptiometry
...Show More Authors

Background: Bone mineral density (BMD) has been assessed using Dual-Energy X-ray absorptiometry (DEXA). This procedure is considered to be of vital importance in assessing the general condition of individuals concerning their skeletal mineralization. BMD is measured according to the results of the DEXA examination of the vertebral column and pelvis. Although diabetes mellitus (D.M.)is known to affect BMD, the information regarding this relationship is not currently particularly clear. Objective: This study concentrates on the point that the assessment of BMD for the vertebral column is insuffi-cient to give a realistic and correct picture of the mineralization of the remaining part of the skeleton. Besides, this study elicited a generalized view of the mineralization of the different body parts between genders and between the left and right sides of the body. The effect of DM I on BMD was evaluated well in this research. Method: This study involved 165 patients complaining of bone pain (85 male and 80 female), about half of whom suffered from diabetes, involving both genders. Further, 90 healthy volunteers had been studied and were considered to constitute the control group. All individuals (255) in this study were exposed to the study of their BMD via DEXA for all parts of the body. Results: The DEXA exam revealed highly statistically significant differences between the sides of the body in the same subject. In addition, there were significant differences in BMD between females and males and highly statistically significant differences between the control and patient groups with DM I. Finally, this study offered strong evidence that the BMD of the vertebral column and pelvis did not give an accurate picture of mineralization in the different parts of the body for a given subject. In conclusion, the DEXA scan for the whole body and each part separately shows promising results as alternative parameters of the DEXA scan for the spine or hip only for accurate diagnosis. Our results indicate that the BMD of the left and right sides for women was less than for men in all cases (average, osteoporosis, and DMI with osteoporosis) for the same sides and between their upper and lower limbs. Patients with DMI revealed significant reductions in BMD in comparison with other subjects who were not diabetic, even if they had osteoporosis. Keywords: DEXA scan, Osteoporosis, DMI, BMD

Scopus Crossref
View Publication
Publication Date
Tue Mar 01 2016
Journal Name
Journal Of Engineering
Some Mechanical Properties of Concrete by using Manufactured Blended Cement with Grinded Local Rocks
...Show More Authors

The  use  of  blended  cement  in  concrete  provides economic, energy savings,  and ecological  benefits, and also  provides. Improvement in the properties of materials incorporating blended cements. The  major  aim  of  this  investigation  is  to  develop  blended  cement  technology using  grinded local rocks . The research includes information on constituent materials, manufacturing processes and performance characteristics of blended cements made with replacement (10 and 20) % of grinded local rocks (limestone, quartzite and porcelinite) from cement.

The main conclusion of this study was that all ty

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Iraqi Journal Of Physics
Immobilization of Nuclear Waste Using Carbon Nanotubes Prepared by Laser Ablation in Liquid Method
...Show More Authors

In an attempt to disposal from nuclear waste which threats our health and environments. Therefore we have to find appropriate method to immobilize nuclear waste. So, in this research the nuclear waste (Strontium hydroxide) was immobilized by Carbon nanotubes (CNTs).  The Nd-YAG laser with wave length 1064 nm, energy 750 mJ and 100 pulses used to prepare CNTs. After that adding Sr(HO)2 powder to the CNTs colloidal in calculated rate to get homogenous mixing of CNTs-Sr(OH)2. The Sr(HO)2 absorbs carbon dioxide from the air to form strontium carbonate so, the  new solution is CNTs-SrCO3. To dry solution putting three drops from the new solution on the glass slides. To investigate the radi

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Improving Treatment Performance of Dissolved Air Flotation System by Using Ionic Liquids as Surfactants
...Show More Authors

The effect of three ionic liquids viz., 1-hexyl-3-methylimidazolium tetrafluoroborate (ILE), 1-hexyl-3-metylimidazolium hexafluorophosphate (ILF) and 1-octyl-3-methylimidazolium tetrafluoroborate (ILG) when used as surfactants on the performance of dissolved air floatation (DAF) was investigated.

   Experiments were conducted at a temperature of 30-35 ºC, 10ppm ferric chloride as coagulant, 50% recycle ratio, pH 8, and 10 minutes treatment time  to find oil and grease (OG) and turbidity removal efficiencies at saturation pressure (2-6) bar.

ILs were used at concentration of 50 µl/liter of treated water in two positions in DAF system; the saturation vessel and the treatment tank. The performance using ILs

... Show More
View Publication Preview PDF
Publication Date
Tue May 28 2019
Journal Name
Al-khwarizmi Engineering Journal
Treatment of Waste Extract Lubricating Oil by Catalytic Cracking Process to Produce Light Fractions
...Show More Authors

The catalytic cracking of three feeds of extract lubricating oil, that produced as a by-product from the process of furfural extraction of lubricating oil base stock in AL-Dura refinery at different operating condition, were carried out at a fixed bed laboratory reactor. The initial boiling point for these feeds was 140 ºC for sample (1), 86 ºC for sample (2) and 80 ºC for sample (3). The catalytic cracking processes were carried out at temperature range 325-400 ºC and initially at atmospheric pressure after 30 minutes over 9.88 % HY-zeolite catalyst load. The comparison between the conversion at different operating conditions of catalytic cracking processes indicates that a high yield was obtained at 375°C, according to gasoline pr

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 01 2016
Journal Name
Journal Of Engineering
Some Mechanical Properties of Concrete by using Manufactured Blended Cement with Grinded Local Rocks
...Show More Authors

The use of blended cement in concrete provides economic, energy savings, and ecological benefits, and also provides. Improvement in the properties of materials incorporating blended cements. The major aim of this investigation is to develop blended cement technology using grinded local rocks . The research includes information on constituent materials, manufacturing processes and performance characteristics of blended cements made with replacement (10 and 20) % of grinded local rocks (limestone, quartzite and porcelinite) from cement. The main conclusion of this study was that all types of manufactured blended cement conformed to the specification according to ASTM C595-12 (chemical and physical requirements). The percentage of the compress

... Show More
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Calculating Surface Roughness for a Large Scale SEM Images by Mean of Image Processing
...Show More Authors

View Publication
Scopus (21)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Sat Apr 25 2020
Journal Name
Asian Journal Of Agriculture And Biology
Biodegradation of plastic wastes by confused flour beetle Tribolium confusum Jacquelin du Val larvae
...Show More Authors

View Publication
Scopus (13)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Mon Oct 05 2015
Journal Name
Diyala Journal For Pure Science
Determination of zinc ions in drinking water distribution systems (PVC pipes) by spectrophotometric method
...Show More Authors

In this work, a method for the simultaneous spectrophotometric determination of zinc which was precipitated into deionized water that is in a commercial distribution systems PVC pipe, is proposed using UV-VIS Spectrophotometer. The method based on the reaction between the analytes Zn2+ and 2-carboxy-2-hyroxy-5-sulfoformazylbenze (Zincon) at an absorption maximum of 620nm at pH 9-10. This ligand is selective reagent. Since the complex is colored (blue), its stoichiometry can be established using visible spectrometry to measure the absorbance of solutions of known composition. The stoichiometry of the complex was determined by Job’s method and molar ratio method and found to be 1:2 (M: L). A series of synthetic solution containing different

... Show More
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi Journal Of Physics
Characteristics of Zinc Oxide Film Prepared by Chemical Spray Deposition as a Gas Sensor
...Show More Authors

Zinc oxide thin films were deposited by chemical spray pyrolysis onto glass substrates which are held at a temperature of 673 K. Some structural, electrical, optical and gas sensing properties of films were studied. The resistance of ZnO thin film exhibits a change of magnitude as the ambient gas is cycled from air to oxygen and nitrogen dioxide

View Publication Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Preparation of Light Fuel Fractions from Heavy Vacuum Gas Oil by Thermal Cracking Reaction
...Show More Authors

This work deals with thermal cracking of heavy vacuum gas oil which produced from the top of vacuum distillation unit at Al- DURA refinery, by continuous process. An experimental laboratory plant scale was constructed in laboratories of chemical engineering department, Al-Nahrain University and Baghdad University. The thermal cracking process was carried out at temperature ranges between 460-560oC and atmospheric pressure with liquid hourly space velocity (LHSV) equal to 15hr-1.The liquid product from thermal cracking unit was distilled by atmospheric distillation device according to ASTM D-86 in order to achieve two fractions, below 220oC as a gasoline fraction and above 220oC as light cycle o

... Show More
View Publication Preview PDF
Crossref