Preferred Language
Articles
/
MRZClocBVTCNdQwC6les
Calculate optical parameters of ions beam from plasma source
...Show More Authors

Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 30 2020
Journal Name
Al-kindy College Medical Journal
Measurement of plasma fibrinogen and D-dimer in a sample of Iraqi patients with solid malignant tumors
...Show More Authors

Background: Multifactor affect the pathogenesis of thrombosis in solid malignancy; however, a significant role is attributed to the cancer cells ability to interact with and activate the host hemostatic system. [1] 

Hemostasis is highly correlated to tumor growth, angiogenesis and metastasis, modulation of these pathways reflects interesting and promising treatment options in the future. [1]

Most patients with cancer frequently suffer from chronic compensated DIC and have abnormal laboratory coagulation tests without clinical manifestations of thrombosis, which is a subclinical hypercoagulable state that can be detected by varying degrees of activation of blood clotting. The results of laboratory tests in th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Effectiveness of Intra articular Injection of Platelet-Rich Plasma in Patients with Anterior Disc Displacement with Reduction
...Show More Authors

Background: Anterior disc displacement with reduction (ADDWR) is the most common form of the internal derangement (ID) of temporomandibular joint (TMJ). It is a painful progressive dysfunction and clinically characterized by reciprocal clicking due to shift in the disc anteriorly in relation to the condyle and fossa during mandible elevation. Minimally invasive therapy such as intra-articular injection of platelet-rich plasma (PRP) has been used. PRP is a natural autologous product with a high platelet concentration obtained by centrifugation process to enhance tissue healing through several growth factors (GFs), which are released after endogenous activation. The aim of this study is to assess this technique which is increasingly used toda

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Nov 08 2022
Journal Name
V. International Scientific Congress Of Pure, Applied And Technological Sciences
The effect of background vacuum pressure on the length of gas discharge plasma by using Aluminum electrodes
...Show More Authors

Length of plasma generated by dc gas discharge under different vacuum pressures was studied experimentally. The cylindrical discharge tube of length 2m was evacuated under vacuum pressure range (0.1-0.5) mbar at constant external working dc voltage 1500V. It was found that the plasma length (L) increased exponentially with increasing of background vacuum air pressure. Empirical equation has been obtained between plasma length and gas pressure by using Logistic model of curve fitting. As vacuum pressure increases the plasma length increases due to collisions, ionizations, and diffusions of electrons and ions.

Publication Date
Sat Nov 04 2017
Journal Name
Silicon
Optimization of Preparation Conditions to Control Structural Characteristics of Silicon Dioxide Nanostructures Prepared by Magnetron Plasma Sputtering
...Show More Authors

View Publication
Scopus (30)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Detection of line shape parameters in normal and abnormal biological tissues
...Show More Authors

Doppler broadening technique is suggested to monitor the development of tumours. It depends on the sensitivity of positronium (Ps) annihilation parameters to the sub- microstructural changes in biological tissues. This technique uses high resolution HpGe detector to measure the lineshape parameters (S and W) in normal mice's mammary tissues and adenocarcinoma mammary tissues as a function of tumour growth. The results demonstrate that the central parameter (S) decreases and the wing parameter (W) increases as the tumour grow. It is found that the S parameter changes considerably with the distribution of voids which are affected by the tumour development. Therefore the present technique can successfully be employed to monitor the developm

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2022
Journal Name
Journal Of Medicinal And Chemical Sciences
Echocardiographic Assessment of the Aortic Stenosis Valve Area: Parameters and Outcome
...Show More Authors

Background: Among individuals who have a stenotic aortic valve, a precise assessment of aortic valve area is essential for clinical judgment. So far, no studies have been conducted to investigate and assess the role of the three dimensional echo-cardiography in the assessment of the valve stenosis. This study aims to compare and assess the precision of the measurement of the stenosis area of the aortic valve by 2D versus 3D echo-cardiography.

Scopus (11)
Scopus
Publication Date
Fri Oct 31 2025
Journal Name
International Review On Modelling And Simulations (iremos)
Denavit-Hartenberg Parameters in the Kinematic Design of Prosthetic Finger Modules
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Nov 15 2024
Journal Name
Iraqi Journal Of Science
Investigating the Correlations between Physical Parameters of Elliptical and Lenticular Galaxies
...Show More Authors

This study aims to investigate the features of stellar-gaseous kinematics and dynamics mass using scaling coefficient relationships (such as the Faber–Jackson relation (FJR)) of two samples of elliptical and lenticular galaxies. These two samples of 80 ellipticals and 97 lenticulars were selected from previous literature works. The Statistical Package for Social Sciences )SPSS( and Matrix Laboratory (MATLAB) program were used to find out the associations of multiple factors under investigation such as main kinematic properties of the gaseous-stellar (effective radius Re, surface density within the effective radius (Ʃeff) , stellar mass in the blue band (Mstar (B)), gas mass ( Mgas), dynamic (Mdyn) and baryonic (Mbar), supermassiv

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Dec 31 2015
Journal Name
Al-khwarizmi Engineering Journal
The Influence of Design and Technological Parameters on the MAF Process
...Show More Authors

Abstract

 Experimental work from Magnetic Abrasive Finishing (MAF) tests was carried out design parameters (amplitude, and number of cycle which are formed the shape of electromagnetic pole), and technological parameters (current, cutting speed, working gap, and finishing time) all have an influence on the mechanical properties of the surface layer in MAF process. This research has made to study the effect of design and technological parameters on the surface roughness (Ra), micro hardness (Hv) and material removal (MR) in working zone. A set of experimental tests has been planned using response surface methodology according to Taguchi matrix (36) with three levels and six factors

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Investigation Parameters of Resistance Spot Welding For AA1050 Aluminum Alloy Sheets
...Show More Authors

The parameters of resistance spot welding (RSW) performed on low strength commercial aluminum sheets are investigated experimentally, the performance requirements and weldability issues were driven the choice of a specific aluminum alloy that was AA1050. RSW aluminum alloys has a major problem of inconsistent quality from weld to weld comparing with welding steel
alloys sheet, due to the higher thermal conductivity, higher thermal expansion, narrow plastic temperature range, and lower electrical resistivity. Much effort has been devoted to the study of describing the relation between the parameters of the process (welding current, welding time, and electrode force) and weld strength. Shear-tensile strength tests were performed to ind

... Show More
View Publication Preview PDF
Crossref (1)
Crossref