Background: The aim of this study was to evaluate and compare the apical microleakage around retrograde cavities prepared with ultrasonic technique and filled with (Biodentine™) Materials and methods: 40 extracted single rooted human permanent maxillary teeth with mature apices were selected. The roots were prepared chemo-mechanically using k-files with crown-down technique and then obturated with lateral condensation gutta-percha technique. Teeth were divided into four main groups according to the cavity preparation method either manual or ultrasonic technique: Group A (n=10): A class I retrograde cavity at root end was prepared with traditional handpeice equipped and placement of Biodentine with manual condensation. Group B (n=10): A class I retrograde cavity at root end was prepared with Piezoelectric ultrasonic device equipped with ultrasonic tip with only manual compaction of the material. Group C (n=10): traditional handpeice and placement of Biodentine using both manual compaction and 5 second ultrasonic activation. Group D (n=10): Piezoelectric ultrasonic device and placement of Biodentine with both manual compaction and 5 second ultrasonic compaction. The teeth were immersed in 1% aqueous Methylene blue dye for 72 hr. Then they were sectioned longitudinally with a diamond disc and the depth of dye penetration was examined under high magnification 20X. Results: Statistical analysis showed a highly significant difference in microleakage among the tested groups in which Piezoelectric technique has proved superiority in retrograde cavity preparation and compaction of Biodentin when dye penetration scores were compared. So microleakage was highest with cavities prepared with handpeice and manual application of retrograde material group A (2.73±0.39) followed by microprepared cavities group C (1.86±0.16), and it was lowest with ultrasonically-prepared cavities group B (1.09±0.28) and group D (0.26±0.19). Conclusion: ultrasonic preparation produced significantly less microleakage than conventional method. Also less microleakage was observed with ultrasonic compaction of Biodentin when compared with conventional method of compaction.
Background: An accurate adaptation of the crown to the finish line is essential to minimize cement dissolution and to preserve periodontium in fixed partial denture cases. An accurate adaptation of crown is possible only when preparation details are captured adequately in the impression and transferred to cast. For these reasons, gingival displacement is necessary to capture subgingival preparation details.The aim of the present study is to measure in vivo the horizontal displacement of the gingival sulcus obtained by using three new cordless retraction materials (Magic Foam Cord®, Racegel and Astringent Retraction Paste) in comparison to medicated retraction cord. Materials and method: Thirty-two patients requiring porcelain fused to me
... Show MoreThis study aimed to find relationship between thymidine kinase-1 (TK-1) as tumor marker and total antioxidant capacity (TAC) in Iraqi children patients with thrombocytopenia and with thrombocytosis. The present study conducted 60 children patients (30 patients with idiopathic thrombocytopenia purpura (ITP) and 30 patients with thrombocytosis caused by leukemia) attending the Children Fever Hospital in the Medical City / Baghdad, and 30 healthy children as a control group. All study groups were with range ages (1-15) years, and they were diagnosed by assay of platelet count, Prothrombin Time (PT), and partial Thromboplastin Time (PTT). The results shown elevation in plasma TK-1 and TAC values in children patients with thrombocytopenia and w
... Show MoreThe purpose of this work was to study the effects of the Nd:YAG laser on exposed dentinal
tubules of human extracted teeth using a scanning electron microscope (SEM). Eighty 2.5mm-thick
slices were cut at the cementoenamel junction from 20 extracted human teeth with an electric saw. A
diamond bur was used to remove the cementum layer to expose the dentinal tubules. Each slice was
sectioned into four equal quadrants and the specimens were randomly divided into four groups (A to D ).
Groups B to D were lased for 2 mins using an Nd:YAG laser at 6 pulses per second at energy outputs of
80 , 100 and 120 mJ. Group A served as control. Under SEM observation, nonlased specimens showed
numerous exposed dentinal tubules. SEM o
To enhance the structural performance of concrete-filled steel tube (CFST) columns, various strengthening techniques have been proposed, including the use of internal steel stiffeners, external wrapping with carbon fiber-reinforced polymer (CFRP) sheets, and embedded steel elements. However, the behavior of concrete-filled stainless-steel tube (CFSST) columns remains insufficiently explored. This study numerically investigates the axial performance of square CFSST columns internally strengthened with embedded I-section steel profiles under biaxial eccentric loading. Finite element (FE) simulations were conducted using ABAQUS v. 6.2, and the developed models were validated against experimental results from the literature. A comprehen
... Show MoreObjective: The descriptive study was used to evaluate nursing staff performance in cardiac care units at teaching
and non teaching hospitals in kirkuk city: A comparative study.
Methodology: A descriptive study was used to evaluate nursing staff performance in cardiac care units. The study
was conducted from December 29th
, 2013 up to the 27th of Apr. 2014. A non-probability (purposive) sample of
(44) nurses who work in cardiac care unit at Azady teaching Hospital and Kirkuk general Hospital was evaluated by
a questionnaire which consisted of two parts; the first part is concerned with the demographic characteristics of
the nurses and the second part concerned Observation check list for evaluation nursing staff Perfo
Since the Internet has been more widely used and more people have access to multimedia content, copyright hacking, and piracy have risen. By the use of watermarking techniques, security, asset protection, and authentication have all been made possible. In this paper, a comparison between fragile and robust watermarking techniques has been presented to benefit them in recent studies to increase the level of security of critical media. A new technique has been suggested when adding an embedded value (129) to each pixel of the cover image and representing it as a key to thwart the attacker, increase security, rise imperceptibility, and make the system faster in detecting the tamper from unauthorized users. Using the two watermarking ty
... Show MoreIn this study, an efficient photocatalyst for dissociation of water was prepared and studied. The chromium oxide (Cr2O3) with Titanium dioxide (TiO2) nanofibers (Cr2O3-TNFs) nanocomposite with (chitosan extract) were synthesized using ecologically friendly methods such as ultrasonic and hydrothermal techniques; such TiO2 exhibits nanofibers (TNFs) shape struct
... Show MoreBackground: The formation of white spot lesions around fixed orthodontic attachments is a common complication during and after fixed orthodontic treatment, which hinders the result of a successfully completed orthodontic treatment. The aim of the study was to assess the effectiveness of the Caries Infiltrant (ICON®) on prevention of caries on the smooth enamel surface when applied alone or combined with conventional adhesives. Materials and methods: Seventy eight human premolar enamel discs were randomly assigned to six groups (n=13). The discs were etched and treated with resins of different monomer content forming the following groups: (1)Untreated etched samples served as the negative control, (2) ICON® (DMG), (3) Adper™ S
... Show MoreBackground: The marginal fit is the most characteristic that closely related to the longevity or success of a restoration, which is absolutely affected by the fabrication technique. The objective of present in vitro study was to evaluate the effect of four different CAD/CAM systems on the marginal fit of lithiµm disilicate all ceramic crowns. Materials and Methods: Adentoform tooth of a right mandibular first molar was prepared to receive all ceramic crown restoration with deep chamfer finishing line (1mm) and axial reduction convergence angle of 6 degree, dentoform model duplicated to have Nickel-Chromiµm master die. Thirty two stone dies produce from master die and distributed randomly in to four groups (8 dies for each group) accor
... Show More