Background: The aim of this study was to evaluate and compare the apical microleakage around retrograde cavities prepared with ultrasonic technique and filled with (Biodentine™) Materials and methods: 40 extracted single rooted human permanent maxillary teeth with mature apices were selected. The roots were prepared chemo-mechanically using k-files with crown-down technique and then obturated with lateral condensation gutta-percha technique. Teeth were divided into four main groups according to the cavity preparation method either manual or ultrasonic technique: Group A (n=10): A class I retrograde cavity at root end was prepared with traditional handpeice equipped and placement of Biodentine with manual condensation. Group B (n=10): A class I retrograde cavity at root end was prepared with Piezoelectric ultrasonic device equipped with ultrasonic tip with only manual compaction of the material. Group C (n=10): traditional handpeice and placement of Biodentine using both manual compaction and 5 second ultrasonic activation. Group D (n=10): Piezoelectric ultrasonic device and placement of Biodentine with both manual compaction and 5 second ultrasonic compaction. The teeth were immersed in 1% aqueous Methylene blue dye for 72 hr. Then they were sectioned longitudinally with a diamond disc and the depth of dye penetration was examined under high magnification 20X. Results: Statistical analysis showed a highly significant difference in microleakage among the tested groups in which Piezoelectric technique has proved superiority in retrograde cavity preparation and compaction of Biodentin when dye penetration scores were compared. So microleakage was highest with cavities prepared with handpeice and manual application of retrograde material group A (2.73±0.39) followed by microprepared cavities group C (1.86±0.16), and it was lowest with ultrasonically-prepared cavities group B (1.09±0.28) and group D (0.26±0.19). Conclusion: ultrasonic preparation produced significantly less microleakage than conventional method. Also less microleakage was observed with ultrasonic compaction of Biodentin when compared with conventional method of compaction.
This study investigates the influence of silver oxide (Ag2O) concentration on the optical characteristics of phosphate bioactive glasses (PBGs). PBGs have emerged as promising alternatives to conventional silicate glasses in the medical field due to their excellent bioactivity and chemical resistance. Samples with varying Ag2O concentrations (0, 0.25, 0.5, and 0.75g) were sintered at 780°C for 2 hrs in an electric furnace. The samples were subjected to Fourier transfer infrared spectroscopy (FTIR), ultraviolet-visible (UV-Vis) spectroscopy, and photoluminescence (PL) tests to assess their functional groups and optical properties. By analyzing the FTIR spectrum of phosphate bioactive glass containing different amounts of Ag2O, it is
... Show MoreBackground: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the
... Show MoreBackground: The study aim was to evaluate thermocycling effect on microleakage of occlusal and cervical margins of MOD cavity filled with bulk filled composites in comparison to incrementally placed nanohybrid composite and to evaluate the difference in microleakage between enamel and dentin margins for the three materials groups. Materials and method: Forty eight maxillary first premolars were prepared with MOD cavities. Samples were divided into three groups of sixteen teeth according to material used: Grandio: Grandio. SDR: SDR +Grandio. X-tra: X-tra base + Grandio. Each group was subdivided into two according to be thermocycled or not. After 24 hrs immersion in 2% methylene blue, samples weresectioned and microleakage was estimated. Res
... Show MoreSoaking dentures with disinfection solutions is an effective way of keeping dentures in a healthy status; however, immersions in these solutions have a negative effect on the bond strength of denture base and denture teeth. The aim of this study was to evaluate the bond strength between denture acrylic teeth and heat-cured Poly (methyl methacrylate) denture base material (with and without nano silica) after disinfection with different chemical disinfectants for a simulated period of six months. One hundred specimens of maxillary central incisors attached to PMMA were divided into two groups; 50 specimens of PMMA without nano silica and 50 specimens of PMMA reinforced with 5 wt% of nano silica. Specimens of each group were immersed in five i
... Show MorePhase-change materials (PCMs) have a remarkable potential for use as efficient energy storage means. However, their poor response rates during energy storage and retrieval modes require the use of heat transfer enhancers to combat these limitations. This research marks the first attempt to explore the potential of dimple-shaped fins for the enhancement of PCM thermal response in a shell-and-tube casing. Fin arrays with different dimensions and diverse distribution patterns were designed and studied to assess the effect of modifying the fin geometric parameters and distribution patterns in various spatial zones of the physical domain. The results indicate that increasing the number of
Background: The purpose of this study was to evaluate and compare centering ability and canal transportation of simulated S-shaped canals instrumented with four different types of rotary nickel-titanium systems. Materials and Methods: Forty simulated S-shaped canals in resin blocks were divided into four groups of ten each and were instrumented to an apical size 25 by different instrumentation technique using ProTaper Universal files (group A), ProTaperNext (group B), Reciproc (group C) and WaveOne (group D).Centering ability and canal transportation was measured at (11) measuring points from D0 to D10 bysuperimposion of the pre- and post-operative images obtained by using digital camera in standardized manner. An assessment of the canals
... Show MoreBackground: This study compared in vitro the marginal adaptation of three different, low shrink, direct posterior composites Filtekâ„¢ P60 (packable composite), Filtekâ„¢ P90 (Silorane-based composite) and Sonic fillâ„¢ (nanohybrid composite) at three different composite/enamel interface regions (occlusal, proximal and gingival regions) of a standardized Class II MO cavity after thermal changes and mechanical load cycling by scanning electron microscopy. Materials and methods:Thirty six sound human maxillary first premolars of approximately comparable sizes were divided into three main groups of (12 teeth) in each according to the type of restorative material that was used: group (A) the teeth were restored with Filtekâ„¢ P6
... Show MoreBackground: While two-thirds of breast cancers express hormone receptors for either estrogen (ER) and/or progesterone (PR) , genetically altered PI3K pathway was found in more than 70% of ER-positive breast cancers.An aberrant activity of cyclin-dependent kinase 1 (CDK1) in a wide variety of human cancers has selectively constituted an attractive pharmacological targets in MYC-dependent human breast cancer cells.
Aim of the study: Role of p110-beta as well as and CDK 1 in the pathogenesis of subset of breast cancers and contribution in their carcinogenesis.
Type of the study: is a retrospective study
Methods: This retr
... Show MoreThe goal of the research is to find the optimization in the test of the appropriate cross-over design for the experiment that the researcher is carrying out (under assumption that there are carry-over effects of the treatments) to posterior periods after the application period (which is often assumed to be the first period). The comparison between the double cross-over design and the cross-over design with extra period. The similarities and differences between the two designs were studied by measuring the Relative Efficiency (RE) of the experiment.