Preferred Language
Articles
/
MBf3840BVTCNdQwCEypV
Simulation and experimentation study on the performance of metal hydride storage vessels
...Show More Authors

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Mar 01 2024
Journal Name
Results In Engineering
Experimental and analytical study of the energy and exergy performance for different evaporative pads in hot and dry climate
...Show More Authors

In this work, effects of using different evaporative cooling pads (ECPs) on the energetic and exergetic efficiency of a direct evaporative air cooler (DEAC) have been theoretically and experimentally investigated. Three types of ECPs were used, i.e., honeycomb cellulose cooler pad (HCCP), shading-cloth cooler pad (SCCP), and aspen wood wool cooler pad (AWWCP). For SCCP and AWWCP, a 3-cm pad thickness was used, while for the HCCP, three different values of pad thickness were used, i.e., 3, 5, and 7 cm. Tests were carried out using air velocities of 8, 14, and 19 m/s, measured at the DEAC outlet. Engineering equation solver (EES) used for performing the required calculations of the various parameters affecting the thermal performance of the D

... Show More
View Publication
Scopus (22)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
The Pharma Innovation
Preparation, spectroscopic study of Schiff base ligand complexes with some metal ions and Evaluation of antibacterial activity
...Show More Authors

Publication Date
Wed Apr 13 2016
Journal Name
The Pharma Innovation Journal
Preparation, spectroscopic study of Schiff base ligand complexes with some metal ions and Evaluation of antibacterial activity
...Show More Authors

The new bidentate Schiff base ligand namely [(E)-N1-(4-methoxy benzylidene) benzene-1, 2-diamine] was prepared from condensation of 4-Methoxy benzaldehyde with O-Phenylene diamine at 1:1 molar ratio in ethanol as a solvent in presence of drops of 48% HBr. The structure of ligand (L) was characterized by, FT-IR, U.V-Vis., 1H-, 13C- NMR spectrophotometer, melting point and elemental microanalysis C.H.N. Metal complexes of the ligand (L) in general molecular formula [M(L)3], where M= Mn(II), Co(II), Ni(II),Cu(II) and Hg(II); L=(C14H14N2O) in ratio (1:3)(Metal:Ligand) were synthesized and characterized by Atomic absorption, FT- IR, U.V-Vis. spectra, molar conductivity, chloride content, melting point and magnetic susceptibility from the above d

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2022
Journal Name
Res Militaris
The impact of the Corona pandemic on the financial performance of companies listed on the Iraqi Stock Exchange
...Show More Authors

This research aims to demonstrate the nature and concept of the Corona pandemic, its implications for the global economy, and the management and performance of companies in particular. Additionally, the research intends to measure the impact of the Corona pandemic on companies' financial performance. Listed on the Iraqi Stock Exchange, which has finished compiling its year-end financial statements for 2019-2020. The investigation arrived at several findings, the most significant of which was that most businesses were not prepared for such a crisis technologically or to develop human resources to deal with this pandemic. In addition, most companies experienced a decrease in their financial performance as a direct result of the Corona pandemi

... Show More
Scopus (4)
Scopus
Publication Date
Wed Mar 31 2021
Journal Name
Indones. J. Chem.,
Synthesis and DFT Study of the Complexation of Schiff Base Derived Curcumin and L-Tyrosine with Al(III), Ag(I), and Pb(II) Metal Ions
...Show More Authors

The multi-dentate Schiff base ligand (H2L), where H2L=2,2'-(((1,3,5,6)-1-(3-((l1-oxidaneyl)-l5-methyl)-4-hydroxyphenyl)-7-(4-hydroxy-3-methoxyphenyl)hepta-1,6-di ene-3,5-diylidene)bis(azaneylylidene))bis(3-(4-hydroxyphenyl)propanoic acid), has been prepared from curcumin and L- Tyrosine amino acid. The synthesized Schiff base ligand (H2L) and the second ligand 1,10-phenanthroline (phen) are used to prepare the new complexes [Al(L)(phen)]Cl, K[Ag(L)(phen)] and [Pb(L)(phen)]. The synthesized compounds are characterized by magnetic susceptibility measurements, micro elemental analysis (C.H.N), mass spectrometry, molar conductance, FT-infrared, UV-visible, atomic absorption (AA), 13C-NMR, and 1H-NMR spectral studies. The characterization of the

... Show More
Preview PDF
Publication Date
Thu Mar 14 2019
Journal Name
Al-khwarizmi Engineering Journal
Creeping Gait Analysis and Simulation of a Quadruped Robot
...Show More Authors

A quadruped (four-legged) robot locomotion has the potential ability for using in different applications such as walking over soft and rough terrains and to grantee the mobility and flexibility. In general, quadruped robots have three main periodic gaits:  creeping gait, running gait and galloping gait. The main problem of the quadruped robot during walking is the needing to be statically stable for slow gaits such as creeping gait. The statically stable walking as a condition depends on the stability margins that calculated particularly for this gait. In this paper, the creeping gait sequence analysis of each leg step during the swing and fixed phases has been carried out. The calculation of the minimum stability margins depends up

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue Nov 01 2011
Journal Name
International Journal Of Mechanical And Materials Engineering
Simulation and design optimization of magneto rheological control valve
...Show More Authors

Magneto-rheological (MR) Valve is one of the devices generally used to control the speed of Hydraulic actuator using MR fluid. The performance of valve depends on the magnetic circuit design. Present study deals with a new design of MR valve. The finite element analysis is carried out on this valve to optimize its design. The design of the magnetic circuit is accomplished by magnetic finite element software such as Finite Element Method Magnetic (FEMM). The Model dimensions of MR valve, material properties and the circuit properties of valve coil are taken into account. The results of analysis are presented in terms of magnetic strength and magnetic flux density. The valve can be operated with variable flow rate by varying the current. It i

... Show More
View Publication Preview PDF
Scopus (2)
Scopus
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Simulation of an ion Optical Transport and Focusing System
...Show More Authors

A simulated ion/electron optical transport and focusing system has been put forward to
be mounted on high voltage transmission electron microscope for in situ investigations.
The suggested system consists of three axially symmetric electrostatic lenses namely an
einzel lens, an accelerating immersion lens, and a decelerating immersion lens, in addition
to an electrostatic quadrupole doublet lens placed on the image side. The electrodes
profile of these lenses is determined from the proposed axial field distributions. The
optical properties of the whole system have been computed together with the trajectory of
the accelerated charged-particles beam along the optical axis of the system. The computed
dimensions of th

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
Newtonian and modified newtonian gravitational simulation of spiral galaxies
...Show More Authors

One of the most powerful tools for any stellar dynamics is the N-body simulation. In an N-body simulation the motion of N particles is followed under their mutual gravitational attraction. In this paper the gravitational N-body simulation is described to investigate Newtonian and non- Newtonian (modified Newtonian dynamics) interaction between the stars of spiral galaxies. It is shown that standard Newtonian interaction requires dark matter to produce the flat rotational curves of the systems under consideration, while modified Newtonian dynamics (MOND) theorem provides a flat rotational curve and gives a good agreement with the observed rotation cu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 18 2022
Journal Name
Heat Transfer
Effect of receiver geometry on the optical and thermal performance of a parabolic trough collector
...Show More Authors
Abstract<p>In this study, the optical and thermal performance of a Parabolic Trough Collector PTC system is investigated theoretically. A series of numerical simulations and theoretical analysis has been conducted to investigate the effect of the receiver geometry and location relative to the focal line on its optical performance. The examined receiver geometries are circular, square, triangular, elliptical and a new design of circular‐ square named as channel receiver. The thermal performance of PTC is studied for different flow rates from (0.27 to 0.6 lpm) theoretically. Results showed that the best optical design is the channel receiver with an optical efficiency of 84% while the worst is the elliptical </p> ... Show More
View Publication
Scopus (20)
Crossref (15)
Scopus Crossref