BACKGROUND: Carcinoma of urinary bladder is one of the most common malignancies worldwide and constitutes a major health problem. Multiple risk factors are associated with this tumor and its prognosis will depend on different clinicopathological parameters. Over expression of P53 protein and mutant Rb gene is associated with more aggressive clinical and histopathological features of the tumor such as advanced stage and higher grade. AIM: The immunohistochemical expression of Rb gene and P53 gene will be assessed through their protein products in transitional cell carcinoma (TCC) of the urinary bladder and then will be correlated with other well-known risk factors and prognostic parameters of bladder TCC, such as grading, tumor size, smoking, alcohol drinking, and family history. METHODS: Patients were recruited from the uro-surgical department/Surgical Subspecialties Teaching Hospital during the period from November 2020 through April 2021. In this study, patients enrolled were those suspected to have bladder carcinoma. The work up included a full history and clinical examination. Surgical samples were taken from the patients for histopathological evaluation; the study’s samples represented either endoscopic cup biopsy, transurethral resection of the tumor, or radical cystectomy. Sections obtained from these samples were stained with the conventional hematoxylin and eosin stain. Then, immunohistochemical staining for P53 and pRB was applied only for patients diagnosed with TCC. RESULTS: The differences between low-grade and high-grade tumors regarding pRb percentage score were statistically significant (p = 0.026), but were not significant regarding the intensity score (p = 0.094). There were significant correlations between tumor stage and both pRb intensity and percentage scores (p = 0.044 and 0.042, respectively). Differences between low-grade and high-grade tumors regarding p53 intensity score were significant (p = 0.022). The differences between low-grade and high-grade tumors regarding p53 percentage score were significant (p = 0.049). The differences between different tumor stages regarding p53 intensity score were significant (p = 0.018). The differences between different tumor stages regarding P53 percentage score were significant (p = 0.019). CONCLUSIONS: Tumor’s grade was found to be correlated with the tumor stage with no correlation with the age, gender, smoking, family history of TCC, history of urinary tract infection, bladder stones, nor the recurrence of the tumor. The pRb intensity and the percentage scores were correlated to each other and to tumor’s grade and stage, except for the pRb intensity which showed no correlation with the tumor’s grade. The P53 intensity and percentage scores were correlated to each other and also to tumor’s grade and stage, so that P53 is over-expressed in tumors with higher grade and stage.
In this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth
This study was designed to compare the effect of two types of viral hepatitis A and E (HAV
and HEV) on liver functions in Iraqi individuals by the measurement of biochemical changes
associated with hepatitis.
The study performed on 58 HEV and 66 HAV infected patients compared with 28 healthy
subjects. The measured biochemical tests include total serum bilirubin, serum transminases (ALT
and AST) alkaline phosphatase (ALP) and gamma glutamyl transferase (GGT).
The study showed that adolescent and young adults (17-29) years, were mostly affected by
HEV while children (5-12) years were frequently affected by HAV. The severity of liver damage in
HEV patients was higher than HAV patients as a result of high serum transa
BACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from Apr
... Show MoreThe paper present design of a control structure that enables integration of a Kinematic neural controller for trajectory tracking of a nonholonomic differential two wheeled mobile robot, then proposes a Kinematic neural controller to direct a National Instrument mobile robot (NI Mobile Robot). The controller is to make the actual velocity of the wheeled mobile robot close the required velocity by guarantees that the trajectory tracking mean squire error converges at minimum tracking error. The proposed tracking control system consists of two layers; The first layer is a multi-layer perceptron neural network system that controls the mobile robot to track the required path , The second layer is an optimization layer ,which is impleme
... Show MoreAlbizia lebbeck biomass was used as an adsorbent material in the present study to remove methyl red dye from an aqueous solution. A central composite rotatable design model was used to predict the dye removal efficiency. The optimization was accomplished under a temperature and mixing control system (37?C) with different particle size of 300 and 600 ?m. Highest adsorption efficiencies were obtained at lower dye concentrations and lower weight of adsorbent. The adsorption time, more than 48 h, was found to have a negative effect on the removal efficiency due to secondary metabolites compounds. However, the adsorption time was found to have a positive effect at high dye concentrations and high adsorbent weight. The colour removal effi
... Show More<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con
... Show MoreThe economic units always sought to maintain its market position and Trchinh the technology management and modern methods that will support success factors .vdila about it has become a customer and one profitability analysis of the most practical way benefit of economic units as modern management focus their attention on achieving this satisfaction, as the customers make up the axis of the success of every organization and that there are many government units aiming to profit directs attention to customers and the number of these units increased continuously. The administration used the customer profitability analysis in order to obtain information to assist in making and decision-making process. How to use modern tec
... Show MorePreparation of identical independent photons is the core of many quantum applications such as entanglement swapping and entangling process. In this work, Hong-Ou-Mandel experiment was performed to evaluate the degree of indistinguishability between independent photons generated from two independent weak coherent sources working at 640 nm. The visibility was 46%, close to the theoretical limit of 50%. The implemented setup can be adopted in quantum key distribution experiments carried out with free space as the channel link, as all the devices and components used are operative in the visible range of the electromagnetic spectrum.
نحو تعزيز المشاركة السياسية للطالبات الجامعيات الفلسطينيات