An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination in pure and pharmaceutical preparations. The developed method is based on the forming of a white, turbid product as a result of a reaction between the warfarin and semicarbazide which was used as an oxidizing agent. The developed flow-through detector system is semi mechanized, economic in materials consumption, easy to operate and characterized by excellent analytical results. Both developed analytical devices used in two channels flow injection system allow for turbidimetric measurements of warfarin in 0.9–154 μg ml−1 and 123–1600 μg ml−1 ranges of concentration, with limits of detections 0.73 μg ml−1 and 24.66 μg ml−1 for photodetectors 1& 2 respectively. The turbidity measurement procedure for the current flow system offers to conduct 60 tests per hour of the warfarin which is the most needs of quality control analysis in industrial applications. To ensure the analytical usefulness of the flow system, the warfarin has been analyzed in the real samples with a fully acceptable agreement and a correlation between the results offered by the developed flow system and the official method.
ولاء طارق حميد, Mustansiriyah Journal of Sports Science, 2021
This research deals with the risks of non-compliance and its impact on the profitability of Islamic banks. Research variables were measured and analyzed as the risk of non-compliance as an independent variableand profitability as a dependent variable. The profitability was measured by three indicators ((rate of return on assets, rate of return on equity and rate of return on Total deposits)) The results of the research showed a significant relationship between the risk of non-compliance and the rate of return on assets and rate of return on total deposits, while there was no relationship between the risk of non-compliance and rate of return on ownership. The research recommended that the senior management of the Islamic Investment Bank s
... Show MoreAbstract:
It is essential to provide health care directly or indirectly based on laboratory tests in order of diagnosing diseases. There is an urgent need for the results of such tests to be accurate and reliable. Therefore, the International Organization for Standardization has prepared special standards for medical laboratories to prove their efficiency, presented in standards 15189: 2012. The aim of the research is to determine the possibility of the Al-alwiya Women's Hospital in meeting the requirements of the standards 15189: 2012, which includes administrative requirements consisting of fifteen items and technical requirements consisting of ten items. The research is important because laboratories shou
... Show MoreThe use of antibiotics (AB) in surgery focused in either treating established infection or to prevent suspected post-operative infection. Inappropriate use of antibiotic for treatment of patients with common infections is a major problem worldwide, with great implications with regards to cost of treatment and development of resistance to the antimicrobial agent. Moreover, antibiotics may often be dispensed without a clear clinical indication. This study was conducted to estimate the medication errors in using antibiotic for surgery patients which may effect their wound healing. A 260 patients with clean-contaminated and contaminated surgery were included from two teaching hospitals, 160 patient from Medical city hospital and 100 fro
... Show MoreThe use of antibiotics (AB) in surgery focused in either treating established infection or to prevent suspected post-operative infection. Inappropriate use of antibiotic for treatment of patients with common infections is a major problem worldwide, with great implications with regards to cost of treatment and development of resistance to the antimicrobial agent. Moreover, antibiotics may often be dispensed without a clear clinical indication. This study was conducted to estimate the medication errors in using antibiotic for surgery patients which may effect their wound healing. A 260 patients with clean-contaminated and contaminated surgery were included from two teaching hospitals, 160 patient from Medical city hospital and 100 from Al-
... Show MoreThe performa of evaluation process is a process that should be carried out by all industrial management in order to stand on aspects of development or underdevelopment of the various departments and activities in its industrial project for the purpose of identifying obstacles and find out the causes and then avoid them quickly. And intended to rectify the performance evaluation of the activities of industrial project or economic union by measuring the results achieved within a specific operational process and compare it to what is already targeted, and often the time for comparison of one year.
The process of performance evaluation depends upon several criteria and indicators within the
... Show MoreAn impressed current cathodic protection system (ICCP) requires measurements of extremely low-level quantities of its electrical characteristics. The current experimental work utilized the Adafruit INA219 sensor module for acquiring the values for voltage, current, and power of a default load, which consumes quite low power and simulates an ICCP system. The main problem is the adaptation of the INA219 sensor to the LabVIEW environment due to the absence of the library of this sensor. This work is devoted to the adaptation of the Adafruit INA219 sensor module in the LabVIEW environment through creating, developing, and successfully testing a Sub VI to be ready for employment in an ICCP system. The sensor output was monitored with an Ardui
... Show MoreThe measurement data of the raw water quality of Tigris River were statistically analyzed to measure the salinity value in relation to the selected raw water quality parameters. The analyzed data were collected from five water treatment plants (WTPs) assembled alongside of the Tigris River in Baghdad: Al-Karkh, Al-Karama, Al-Qadisiya, Al-Dora, and Al-Wihda for the period from 2015 to 2021. The selected parameters are total dissolved solid (TDS), electrical conductivity (EC), pH and temperature. The main objective of this research is to predicate a mathematical model using SPSS software to calculate the value of salinity along the river, in addition, the effect of electrical conductivi
An impressed current cathodic protection system (ICCP) requires measurements of extremely low-level quantities of its electrical characteristics. The current experimental work utilized the Adafruit INA219 sensor module for acquiring the values for voltage, current, and power of a default load, which consumes quite low power and simulates an ICCP system. The main problem is the adaptation of the INA219 sensor to the LabVIEW environment due to the absence of the library of this sensor. This work is devoted to the adaptation of the Adafruit INA219 sensor module in the LabVIEW environment through creating, developing, and successfully testing a Sub VI to be ready for employment in an ICCP system. The sensor output was monitored with an Arduino
... Show More