An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination in pure and pharmaceutical preparations. The developed method is based on the forming of a white, turbid product as a result of a reaction between the warfarin and semicarbazide which was used as an oxidizing agent. The developed flow-through detector system is semi mechanized, economic in materials consumption, easy to operate and characterized by excellent analytical results. Both developed analytical devices used in two channels flow injection system allow for turbidimetric measurements of warfarin in 0.9–154 μg ml−1 and 123–1600 μg ml−1 ranges of concentration, with limits of detections 0.73 μg ml−1 and 24.66 μg ml−1 for photodetectors 1& 2 respectively. The turbidity measurement procedure for the current flow system offers to conduct 60 tests per hour of the warfarin which is the most needs of quality control analysis in industrial applications. To ensure the analytical usefulness of the flow system, the warfarin has been analyzed in the real samples with a fully acceptable agreement and a correlation between the results offered by the developed flow system and the official method.
The research aims to show the impact that the information of the supporting bodies can have and its dimensions represented by (information credibility, efficiency and effectiveness of information, cooperation with the tax administration, obligating the taxpayer, accuracy and completeness of information and the appropriate time) in tax inventory, as well as clarifying the moral differences in The response of the surveyed sample according to the personal variables represented by (gender, educational attainment, scientific specialization, job title, years of service), and the descriptive analytical approach was adopted and in light of it, the questionnaire was designed as a main tool in collecting data from the sample of (80)
... Show MoreQuality function deployment tool is trying to improve health services through this study that will be applied in health sector environment , and be based on applying quality function deployment tool (QFD) TO preferable evaluation of main patients requirements in order to determine the technical requirements that need most attention across improving and developing health services .
Main requirements are determined to patients lying in the hospital (under research) which is (educational Baghdad \ medicine city office) in Baghdad, and other technical requirements through pers
... Show MoreThe research focuses on the withdrawal of the United States from the nuclear agreement signed between the permanent members of the United Nations Security Council and the Islamic Republic of Iran concerning its nuclear program. This withdrawal has caused disruption in the official media discourse of the concerned countries. Therefore, the main question can be posed: Are there differences in the positions of countries related to the nuclear agreement, as well as those countries affected by it, before and after the official withdrawal of the United States on May 8, 2018?
The research aims to shed light on the trends in media discourse of the countries that signed the nuclear agreement and those affected by it b
The electoral poster is the most important means and methods of the electoral campaign because of its advantages and capabilities if it is organized properly. It is an intensive propaganda message with psychological figures and semiotic connotations belonging to sub-culture. Its construction depends on a group of elements (logo, photo symbols, color and picture) and their consistency is varying from one to another. Posters must be committed the determinants of attraction, excitement, simplicity and clarity. They are working according to the following base: (fixed audience X moved recipients) and walking towards (moving X moving) due to the technical development of optical screens. These developments require double the force of the impact
... Show MoreThis study aimed at accounting for the role of talents management in consolidating organizational learning process at the Yemeni General Corporation For telecommunication. To achieve the objective of the study, the researcher designed a questionnaire and administered it. The sample of the study consisted of (166) employees (General Manager, Manager and Department Head). They were selected randomly out of a total Population of (291) employees during the Year 2019. The descriptive analytic approach was used t reach conclusions.
The finding of the study revealed existence of effect of talents management dimensions, all together and alone, (talents polarization, talents development, talents maintenance and ma
... Show MoreThe current study aims to test the impact of green training and development on sustainable performance and explore its effects within and outside the Iraqi Ministry of Environment. The main research problem revolves around the question of the extent of implementing green training and development and sustainable performance in the ministry (What is the nature of the relationship between green training and development and sustainable performance in the ministry?). To clarify the relationship between the research variables, two main hypotheses were formulated along with sub-hypotheses. The study also aims to assess the level of the ministry's interest in the research variables and provide key recommendations to enhance sustainable performan
... Show MoreObjective. This study aimed to evaluate and compare the force degradation of two types of elastomeric chains following different periods of immersion in zinc-containing mouthwashes. Materials and Methods. Four hundred and forty pieces of Elasto-Force and Super Elasto-Force elastomeric chains were divided into two control and eight experimental groups. The pieces were stretched to 25 mm on pins mounted on an acrylic block and stored in distilled water at 37°C. The experimental groups were immersed in four different types of mouthwash for one minute twice a day throughout the test period. Ten continuous thermocycles per day between cold and hot water baths (5–55°C) were carried out. Forces were measured at six-time intervals (in
... Show MoreThis research aims to identify the role that forensic accounting plays on the transparency and quality of the financial statements in trade bank of Iraq and the Gulf Commercial Bank in Babylon. This research came to address the problem that most financial institutions suffer from, which is represented by the lack of transparency and the quality of the financial statements issued in a manner. Annual also the manipulation and fraud in the financial data, which causes a big gap between that institutions and organizational stakeholders. According to the implementation of the research hypothesis and the objectives of the research, a questionnaire was prepared consisting of three axes, the first axis dealing with the demographic distri
... Show MoreThe research involved a rapid, automated and highly accurate developed CFIA/MZ technique for estimation of phenylephrine hydrochloride (PHE) in pure, dosage forms and biological sample. This method is based on oxidative coupling reaction of 2,4-dinitrophenylhydrazine (DNPH) with PHE in existence of sodium periodate as oxidizing agent in alkaline medium to form a red colored product at ʎmax )520 nm (. A flow rate of 4.3 mL.min-1 using distilled water as a carrier, the method of FIA proved to be as a sensitive and economic analytical tool for estimation of PHE.
Within the concentration range of 5-300 μg.mL-1, a calibration curve was rectilinear, where the detection limit was 3.252 μg.mL