Fire is one of the most critical risks devastating to human life and property. Therefore, humans make different efforts to deal with fire hazards. Many techniques have been developed to assess fire safety risks. One of these methods is to predict the outbreak of a fire in buildings, and although it is hard to predict when a fire will start, it is critical to do so to safeguard human life and property. This research deals with evaluating the safety risks of the existing building in the city of Samawah/Iraq and determining the appropriateness of these buildings in terms of safety from fire hazards. Twelve parameters are certified based on the National Fire Protection Association (NFPA2016) code. The concept of giving weight to each criterion was adopted to classify the criteria according to their importance and then conduct an on-site examination of these existing buildings to test the selected criteria. The result indicates a possible fire risk in these buildings due to the lack of compliance with fire safety instructions in the approved codes.
Air pollution evaluation of the operational processes in the East Baghdad oil field was carried out. The analysis was carried out by ICP-MS technique. Total Suspended Particles (TSP) air load was higher than Iraqi Standards and world international allowable limits of World Health Organization. The mean concentrations of gases carbon monoxide, carbon dioxide, sulfur dioxide, in the air were within national and world standards, while the mean concentration of nitrogen dioxide was higher than standard limits. The air of the study area is considered a good quality for CO, CO2 and NO2 with no health effect, while it is hazardous for TSP that have serious risk for people with respiratory disease. The mean concentrations of Cd, Cr, Cu and
... Show MoreThis paper analysed the effect of electronic internal auditing (EIA) based on the Control Objectives for Information and Related Technologies (COBIT) framework. Organisations must implement an up-to-date accounting information system (AIS) capable of meeting their auditing requirements. Electronic audit risk (compliance assessment, control assurance, and risk assessment) is a development by Weidenmier and Ramamoorti (2006) to improve AIS. In order to fulfil the study’s objectives, a questionnaire was prepared and distributed to a sample comprising 120 employees. The employees were financial managers, internal auditors, and workers involved in the company’s information security departments in the General Company for Electricity D
... Show MoreHelicobacter pylori (HP) is the etiopathogenic agent of gastric and duodenal disorders ranging from gastritis to malignancy. It is also associated with many extraintestinal diseases, including cardiovascular disease and its associated risk factors. To evaluate the link between HP infection and some cardiovascular risk factors by studying the effects of HP infection on body mass index, blood pressure, and serum lipid profile among patients having gastritis with and without HP infection. A crosssectional study included 1214 patients who had gastritis diagnosed by gastroscopy examination. Those patients were in the age range of 30-65 years and they were divided according to their gender into 725 females and 489 males depending on the 1
... Show MoreBackground: Although radiological diagnostic studies (RDS) are an important and acceptable part of medical practice, it is not without hazards. It is associated with increased risk of cancer. Unfortunately the typical and safe dose of each radiological examination is not known. Most of our knowledge of cancer risk comes from studies of survivors of those exposed to whole body radiation from atomic bomb in Hiroshima & Nagasaki, jobs associated with radiation exposure, Chernobyl survivors & patients treated with radiation therapy for cancer and other diseases.
Objectives To estimate radiation dose received by patients from diagnostic radiological examinations and lifetime
... Show MoreTo damp the low-frequency oscillations which occurred due to the disturbances in the electrical power system, the generators are equipped with Power System Stabilizer (PSS) that provide supplementary feedback stabilizing signals. The low-frequency oscillations in power system are classified as local mode oscillations, intra-area mode oscillation, and interarea mode oscillations. Double input multiband Power system stabilizers (PSSs) were used to damp out low-frequency oscillations in power system. Among dual-input PSSs, PSS4B offers superior transient performance. Power system simulator for engineering (PSS/E) software was adopted to test and evaluate the dynamic performance of PSS4B model on Iraqi national grid. The results showed
... Show MoreIn this study, we made a comparison between LASSO & SCAD methods, which are two special methods for dealing with models in partial quantile regression. (Nadaraya & Watson Kernel) was used to estimate the non-parametric part ;in addition, the rule of thumb method was used to estimate the smoothing bandwidth (h). Penalty methods proved to be efficient in estimating the regression coefficients, but the SCAD method according to the mean squared error criterion (MSE) was the best after estimating the missing data using the mean imputation method
Imaging by Ultrasound (US) is an accurate and useful modality for the assessment of gestational age (GA), estimation fetal weight, and monitoring the fetal growth during pregnancy, is a routine part of prenatal care, and that can greatly impact obstetric management. Estimation of GA is important in obstetric care, making appropriate management decisions requires accurate appraisal of GA. Accurate GA estimation may assist obstetricians in appropriately counseling women who are at risk of a preterm delivery about likely neonatal outcomes, and it is essential in the evaluation of the fetal growth and detection of intrauterine growth restriction. There are many formulas are used to estimate fetal GA in the world, but it's not specify fo
... Show MoreAn accurate assessment of the pipes’ conditions is required for effective management of the trunk sewers. In this paper the semi-Markov model was developed and tested using the sewer dataset from the Zublin trunk sewer in Baghdad, Iraq, in order to evaluate the future performance of the sewer. For the development of this model the cumulative waiting time distribution of sewers was used in each condition that was derived directly from the sewer condition class and age data. Results showed that the semi-Markov model was inconsistent with the data by adopting ( 2 test) and also, showed that the error in prediction is due to lack of data on the sewer waiting times at each condition state which can be solved by using successive conditi
... Show More