Purpose: The purpose of this study was to compare the outcomes of 2 different anesthetic techniques (local infiltration vs infraorbital nerve block) for eliminating pain during apical surgeries that are associated with extensive periapical pathology in the anterior maxilla. Materials and Methods: Patients were randomly divided into 2 groups: patients in group I were anesthetized labially by local infiltration injections, whereas those in group II received a single infraorbital nerve block. Palatal injections were given for the 2 groups. Once the pain was initiated during surgery, the procedure was discontinued until profound anesthesia was secured. The studied variables were age, gender, onset of anesthesia, operative time, and intraoperative pain. Any complication associated with the injection techniques, intraoperatively and postoperatively, also was assessed and recorded. Then, the collected data were analyzed using proper statistical methods. The significance level was set at a P value less than or equal to .05. Results: One hundred patients (50 per group; age range, 16 to 43 yr), predominantly men, were enrolled in this study. The results showed rapid onset of anesthesia in group II with a highly significant difference from group I (P #.05). Duration of the operation ranged from 44 to 57 minutes. Pain during the surgical procedure was reported by most patients in group I (92%). Collateral anesthesia (82%) and increased numbness of the upper lip (72%) were reported in group I. Ecchymosis at the infraorbital foramen or rim (8%) and paresthesia in the skin over the infraorbital region (6%) and cheek (4%) were observed in group II. Conclusions: In apical surgeries, the anesthetic efficiency of the infraorbital nerve block was superior to that of local infiltration. It had rapid onset, longer duration, and greater potency and avoided multiple transmucosal injections. Furthermore, it was associated with minor and transient side effects.
Background: Implant stability is a mandatory factor for dental implant (DI) osseointegration and long-term success. The aim of this study was to evaluate the effect of implant length, diameter, and recipient jaw on the pre- and post-functional loading stability. Materials and methods: This study included 17 healthy patients with an age range of 24-61 years. Twenty-two DI were inserted into healed extraction sockets to replace missing tooth/ teeth in premolar and molar regions in upper and lower jaws. Implant stability was measured for each implant and was recorded as implant stability quotient (ISQ) immediately (ISQ0), and at 8 (ISQ8) and 12 (ISQ12) weeks postoperatively, as well as post-functional loading (ISQPFL). The pattern of implant
... Show MoreThe research aims to reach a set of objectives concerning creation a clear vision about conceptual, philosophical and practical dimension of relations, and effects between knowledge management, costumer orientation and competitiveness to construct a framework of a pragmatic model as a solution to research problem and its questions which the main one is about the role of knowledge management and costumer orientation in competitiveness of business organizations. To achieving this goal, it was necessary to make, in priory, a review and discussion to the theoretical dimension of research variables to have a clear vision about constructing hypostatical research model implying a set of hypotheses which, by proving them in companies studied, repr
... Show MoreThe main objective of this study is to experimentally investigate the effect of the CMC polymeric drag reducer on the pressure drop occurred along the annulus of the wellbore in drilling operation and investigate the optimum polymer concentration that give the minimum pressure drop. A flow loop was designed for this purpose consist from 14 m long with transparent test section and differential pressure transmitter that allows to sense and measure the pressure losses along the test section. The results from the experimental work show that increasing in polymer concentration help to reduce the pressure drop in annulus and the optimum polymer concentration with the maximum drag reducing is 0.8 kg/m3. Also increasing in flow rate a
... Show MoreThe duration of the contract is a legal term first provided for in French Amendment Decree No. 131/2016, and given the increasing importance of time in contracts, we have chosen to study the legal rules governing time at the formative stage by drawing on changes in French law compared to both Iraqi and Egyptian laws. Article 1102 of French Amendment Decree No. 131/2016 stipulates that: "Everyone is free to contract or not to contract, to choose the person with whom he contracts, and to determine the content and form of the contract within the limits established by law." Contractual freedom does not permit a breach of the rules relating to public order), as well as article 1104, which provides for (contracts must be nego
... Show MoreViolence occurs as a daily human action all over the world; it may cause so many kinds of damage to individuals as well as to society: physical, psychological, or both. Many literary authors of different genres have tried their best to portray violence by showing its negative effects, especially playwrights because they have the chance to show people the dangers of violence through performance on stage to warn them against such negatively affected action. It has been a human action since the beginning of human life on this planet when the first crime happened on earth when Cane killed his brother Abel. In our modern world, people are witnessing daily violent actions as a result of destructive wars that turned the humans into brutal beings.
... Show MoreThis study looks into the many methods that are used in the risk assessment procedure that is used in the construction industry nowadays. As a result of the slow adoption of novel assessment methods, professionals frequently resort to strategies that have previously been validated as being successful. When it comes to risk assessment, having a precise analytical tool that uses the cost of risk as a measurement and draws on the knowledge of professionals could potentially assist bridge the gap between theory and practice. This step will examine relevant literature, sort articles according to their published year, and identify domains and qualities. Consequently, the most significant findings have been presented in a manne
... Show MoreIn addition to the primary treatment, biological treatment is used to reduce inorganic and organic components in the wastewater. The separation of biomass from treated wastewater is usually important to meet the effluent disposal requirements, so the MBBR system has been one of the most important modern technologies that use plastic tankers to transport biomass with wastewater, which works in pure biofilm, at low concentrations of suspended solids. However, biological treatment has been developed using the active sludge mixing process with MBBR. Turbo4bio was established as a sustainable and cost-effective solution for wastewater treatment plants in the early 1990s and ran on minimal sludge, and is easy to maintain. This
... Show MoreThe development of human resources training programs has an applied and important role in the preparation of human cadresin terms of capacity to absorb technical sciences and skills and scientific and practical practices at faster rates in order to bealighed with continous development. Hence the recognition of the significant role that human resources play in the economy of any country,which has stressed the interest towards the economic unity of the qualified staff that it needsin atimely manner through the ongoing training process in the era of high technology day by day In this regard ,the current research deal with accounting of human resources and its impact on reducing costs in the military establishment and the
... Show MoreBackground: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M
... Show More