The main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperatu
... Show MoreObjective: To find out if there are any significant differences between these women's knowledge in the
management of Breast Self-Examination in study and control group regarding some variables.
Methodology: A quasi-experimental design was used. A purposive "non-probability" sample of (260) women who
are employee and students in both colleges (Nursing and Health and Medical Technologies) was selected. The
sample consists of two groups, experimental group (130) includes those in (Nursing college), and control group
(130) in (Health and Medical Technologies). A questionnaire was constructed which included demographic
information, reproductive information, family history, previous medical history, and information about wome
Background: Ultrasound guided core needle biopsy is becoming a gold standard in the work up of suspicious breast lesion. In Iraq, radiologists are not taking the lead in core needle biopsy performance.
Objectives: To evaluate the radiologist performance of core needle biopsy highlighting the precession and accuracy of the procedure, the concordance of ultrasound and histopathology, and identifying challenges facing the radiologist during the procedure.
Subjects and Methods: A prospective study involving a total of 50 patients with ultrasound (US) BIRADS IV or V. Ultrasound guided core needle biopsy was performed for each patient. Surgical pathol
... Show MoreThe study aimed to identify the news framing on the Israeli Arabic-speaking i24 channel of the Israeli aggression on Gaza -2021 by analyzing the channel’s Program “this evening”. The study used the media survey method, and in its framework, it relied on the content analysis method for the program’s episodes from May 5, 2021 AD until June 4, 2021 AD, with 22 episodes. The study showed the program’s interest in launching the Palestinian resistance’s rockets significantly, followed by the Israeli military operations, and the program’s reliance on correspondents largely as a source of news material related to the aggression. It also proved that a news report and a reporter's report was the most important form of presenting news
... Show MoreReintervention after balloon angioplasty is often considered inevitable in children with coarctation of the aorta (COA). The present study aimed to evaluate predictors of re-intervention after balloon angioplasty for COA, with the goal of identifying patient and procedural characteristics that may influence long-term outcomes
This is an open access by CC Attribution-Noncommercial-NoDerivatives 4.0
https://creativecommons.org/licenses/by-nc-nd/4.0
Takfir is an ancient phenomenon that accompanied the emergence of Islam, and this phenomenon took its political dimension during the time of the fourth Rashidi Caliph with the emergence ofthe Kharijites sect that disbelieved many Muslims.
The study started from the hypothesis that "contemporary Islamicmovements and organizations have relied in their takfir on the ideas and fatwas presented by the predecessors which applied ontocontemporary rea
... Show MoreFind all boils down to is marked with (recruitment aesthetic of digital technology for (color) in the film novelist) And the relationship between the aesthetic employment of digital technology for (color) and its impacts on the level of artistic creativity through digital technology and its impacts on the technical and completed the final film in the film.Search and distributed at five chapters The first chapter discusses the methodological framework of the research, which included the research problem and is as follows:What is the digital technology to enrich color in the context in the film narrative to reflect the dramatic effect?And the importance of research and its objectives, including:1 - Employment aesthetic of digital technolog
... Show MoreThe present study combines UV-Vis spectrophotometry and dispersive liquid-liquid microextraction (DLLME) for the preconcentration and determination of trace level clidinium bromide (Clid) in pharmaceutical preparation and real samples. The method is based on ion-pair formation between Clid and bromocresol green in aqueous solution using citrate buffer (pH = 3). The colored product was first extracted using a mixture of 800 µL acetonitrile and 300 µL chloroform solvents. Then, a spectrophotometric measurement of sediment phase was performed at λ = 420 nm. The important parameters affecting the efficiency of DLLME were optimized. Under the optimum conditions, the calibration graphs of standard -1 (Std.), drug, urine and serum were ranged
... Show MoreThe gamma dose rates and specific activity of 137Cs, 60Co and 40K in
samples of soil taken from places near the landfill radiation at Al-
Tuwaitha site were measured using a portable NaI(Tl) detector. The
results of gamma dose rates in samples were ranged from 52.6
nGy.h-1 to 131nGy.h-1. Then the specific activity of 137Cs, 60Co and
40K in soil were determined using high pure germanium (HPGe)
detector. The specific activities were varied from 1.9 to 115500 Bq.
kg-1 for 137Cs, from 6.37 to 616.5 Bq. kg-1 for 60Co, and from 3 to
839.5 Bq. kg-1 for 40K. The corresponding health risk for the annual
effective dose equivalent varied from 1.85×10-14 to 15.7mSv/y. The
results were compared with various internationa
This work aimed to produce PVA and PVA/Ag nanofibers ultra-high sensitivity photodetector by electrospinning. The electrospinning process was used to successfully prepare PVA nanofibers and a PVA-Ag nanofiber composite. FE-SEM, XRD, UV, I-V characterizations are used to study the morphological, structural, optical, and electrical properties of the material. In contrast, the PVA-Ag nanofiber composite film displayed a cubic structure with favored orientation (200) that indicated the presence of Ag NPs in the PVA-Ag nanofibers film. While the optical energy gap for PVA was 3.96 eV, it was only 2.14 eV for PVA-Ag nanofibers composite film, making this composite sensitive to visible light, particularly green light at 550 nm with a 65% photosens
... Show More