In this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In addition, temperature tested at range of (25-55) C˚, and it has been figured out which photodegradation percent of dye increase with raising temperature (degradation percent was ~ 98% after irradiation time of 4 hours at 55 C˚), and the activation energy of the reaction was calculated (34.8016 kJ/mole) from Arrhenius law. The thermodynamic functions ΔH#, ΔG#, and ΔS# were obtained, where ΔH# and ΔG# are positive value which means that the reaction is endothermic and non-spontaneous respectively, while ΔS# has a negative value, thus indicates that the reactants are more disordered than the excited intermediate formed. The kinetic of the reaction was studied, and it has been found that the photocatalytic reaction follows pseudo first order reaction.
The neutrophil/ lymphocyte ratio (NLR) and platelet/lymphocyte ratio (PLR) have the potential to be inflammatory markers that reflect the activity of many inflammatory diseases. The aim of this study was to evaluate the NLR and PLR as potential markers of disease activity in patients with ankylosing spondylitis.
The study involved 132 patients with ankylosing spondylitis and 81 healthy controls matched in terms of age and gender. Their sociodemographic data, disease activity scores using the Bath Ankylosing
Resin-modified glass ionomer cement tends to shrink due to polymerization of the resin component. Additionally, they are more prone to syneresis and imbibition during the setting process. This
Background: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St
... Show More