The rapid and enormous growth of the Internet of Things, as well as its widespread adoption, has resulted in the production of massive quantities of data that must be processed and sent to the cloud, but the delay in processing the data and the time it takes to send it to the cloud has resulted in the emergence of fog, a new generation of cloud in which the fog serves as an extension of cloud services at the edge of the network, reducing latency and traffic. The distribution of computational resources to minimize makespan and running costs is one of the disadvantages of fog computing. This paper provides a new approach for improving the task scheduling problem in a Cloud-Fog environment in terms of execution time(makespan) and operating costs for Bag-of-Tasks applications. A task scheduling evolutionary algorithm has been proposed. A single custom representation of the problem and a uniform intersection are built for the proposed algorithm. Furthermore, the individual initialization and perturbation operators (crossover and mutation) were created to resolve the inapplicability of any solution found or reached by the proposed evolutionary algorithm. The proposed ETS (Evolutionary Task Scheduling algorithm) algorithm was evaluated on 11 datasets of varying size in a number of tasks. The ETS outperformed the Bee Life (BLA), Modified Particle Swarm (MPSO), and RR algorithms in terms of Makespan and operating costs, according to the results of the experiments.
Objective: To determine the effectiveness of hypothermia on renal functions for patients undergoing
coronary artery bypass graft CABG surgery.
Methodology: A purposive (non-probability) sample of (50) patients undergoing Isolated coronary artery
bypass graft surgery consecutively admitted to the surgical ward, and they were followed up in the
intraoperative, Intensive Care Unit (ICU) and in the postoperative (surgical ward). Post-operative renal function
test (glumeruler filteration rate (GFR) by using the Crockroft-Gault formula and serum creatinine level) was
determined first week post operative and post operative renal function was classified on the base of peak of
the serum creatinine level and decline of glomeru
The ground charge density distributions (CDD), elastic charge form factors and proton, charge, neutron, and matter root mean square (rms) radii for stable 40Ca and 48Ca have been calculated using single-particle radial wave functions of Woods-Saxon (WS) and harmonic-oscillator (HO) potentials. Different central potential depths are used for each subshell which is adjusted so as to reproduce the experimental single-nucleon binding energies. An excellent agreement between the calculated rms charge radii and experimental data are found for both nuclei using WS and HO potentials. The calculated proton rms radii for 40Ca are found to be in good agreement with experiment data using both WS and HO potentials while the results for 48Ca showed an ov
... Show MoreThe purpose of this experiment was to determine the relationship between the path coefficient and seed rate for four different barley cultivars (Amal, Ibaa 265, Ibaa 99, and Buhooth 244) during the 2019-2020 winter season. The experiment was carried out using a split plot design with three replications according to a randomized complete block design (RCBD). The highest positive thru effect on grain yield was found for flag leaf area and harvest index at aseeding rate of 130 kg.h-1; the highest positive direct effect on grain yield was found for flag leaf area and plant height at aseeding rate of 160 kg.h-1; and the highest positive direct effe
A total of 20 raw milk samples were used as the fouling agent for evaluating the bacteriological effectiveness of cleaning and sanitizing of domestic milking equipment by using ozonated water at 0.5 ppm comparing to the warm water at 55! for 5 minutes respectively. The mean values of total aerobic bacteria, Coliform and E.coli that present on the plastic and stainless-steel containers after using the raw milk as fouling agent were 3.4×10-6 , 6.7x10-5 and 5.8×10-3 cfu/cm2 respectively , after cleaning the stainless steel containers by the ozonated water the mean values of total aerobic bacterial counts, Coliforms and E.coli bacteria were reduced to 1.2×10-6, 4.7×10-5 and 3.3×10-3 CFU/cm2 respectively. while after cleaning by the warm wa
... Show More